| From 725e37cd14866906ba28c970394b9f7a4cd97413 Mon Sep 17 00:00:00 2001
 | |
| From: Blazej Kucman <blazej.kucman@intel.com>
 | |
| Date: Mon, 19 Dec 2022 11:21:58 +0100
 | |
| Subject: [PATCH 64/83] Update mdadm Monitor manual.
 | |
| 
 | |
| - describe monitor work modes,
 | |
| - clarify the turning off condition,
 | |
| - describe the mdmonitor.service as a prefered management way.
 | |
| 
 | |
| Signed-off-by: Blazej Kucman <blazej.kucman@intel.com>
 | |
| Signed-off-by: Jes Sorensen <jes@trained-monkey.org>
 | |
| ---
 | |
|  mdadm.8.in | 71 ++++++++++++++++++++++++++++++++++++++----------------
 | |
|  1 file changed, 50 insertions(+), 21 deletions(-)
 | |
| 
 | |
| diff --git a/mdadm.8.in b/mdadm.8.in
 | |
| index 70c79d1e..64f71ed1 100644
 | |
| --- a/mdadm.8.in
 | |
| +++ b/mdadm.8.in
 | |
| @@ -2548,13 +2548,33 @@ Usage:
 | |
|  .I options... devices...
 | |
|  
 | |
|  .PP
 | |
| -This usage causes
 | |
| +Monitor option can work in two modes:
 | |
| +.IP \(bu 4
 | |
| +system wide mode, follow all md devices based on
 | |
| +.B /proc/mdstat,
 | |
| +.IP \(bu 4
 | |
| +follow only specified MD devices in command line.
 | |
| +.PP
 | |
| +
 | |
| +.B \-\-scan -
 | |
| +indicates system wide mode. Option causes the
 | |
| +.I monitor
 | |
| +to track all md devices that appear in
 | |
| +.B /proc/mdstat.
 | |
| +If it is not set, then at least one
 | |
| +.B device
 | |
| +must be specified.
 | |
| +
 | |
| +Monitor usage causes
 | |
|  .I mdadm
 | |
|  to periodically poll a number of md arrays and to report on any events
 | |
|  noticed.
 | |
| -.I mdadm
 | |
| -will never exit once it decides that there are arrays to be checked,
 | |
| -so it should normally be run in the background.
 | |
| +
 | |
| +In both modes,
 | |
| +.I monitor
 | |
| +will work as long as there is an active array with redundancy and it is defined to follow (for
 | |
| +.B \-\-scan
 | |
| +every array is followed).
 | |
|  
 | |
|  As well as reporting events,
 | |
|  .I mdadm
 | |
| @@ -2565,15 +2585,6 @@ or
 | |
|  .B domain
 | |
|  and if the destination array has a failed drive but no spares.
 | |
|  
 | |
| -If any devices are listed on the command line,
 | |
| -.I mdadm
 | |
| -will only monitor those devices, otherwise, all arrays listed in the
 | |
| -configuration file will be monitored.  Further, if
 | |
| -.B \-\-scan
 | |
| -is given, then any other md devices that appear in
 | |
| -.B /proc/mdstat
 | |
| -will also be monitored.
 | |
| -
 | |
|  The result of monitoring the arrays is the generation of events.
 | |
|  These events are passed to a separate program (if specified) and may
 | |
|  be mailed to a given E-mail address.
 | |
| @@ -2586,16 +2597,34 @@ device if relevant (such as a component device that has failed).
 | |
|  
 | |
|  If
 | |
|  .B \-\-scan
 | |
| -is given, then a program or an E-mail address must be specified on the
 | |
| -command line or in the config file.  If neither are available, then
 | |
| +is given, then a
 | |
| +.B program
 | |
| +or an
 | |
| +.B e-mail
 | |
| +address must be specified on the
 | |
| +command line or in the config file. If neither are available, then
 | |
|  .I mdadm
 | |
|  will not monitor anything.
 | |
| -Without
 | |
| -.B \-\-scan,
 | |
| -.I mdadm
 | |
| -will continue monitoring as long as something was found to monitor.  If
 | |
| -no program or email is given, then each event is reported to
 | |
| -.BR stdout .
 | |
| +For devices given directly in command line, without
 | |
| +.B program
 | |
| +or
 | |
| +.B email
 | |
| +specified, each event is reported to
 | |
| +.BR stdout.
 | |
| +
 | |
| +Note: For systems where
 | |
| +.If mdadm monitor
 | |
| +is configured via systemd,
 | |
| +.B mdmonitor(mdmonitor.service)
 | |
| +should be configured. The service is designed to be primary solution for array monitoring,
 | |
| +it is configured to work in system wide mode.
 | |
| +It is automatically started and stopped according to current state and types of MD arrays in system.
 | |
| +The service may require additional configuration, like
 | |
| +.B e-mail
 | |
| +or
 | |
| +.B delay.
 | |
| +That should be done in
 | |
| +.B mdadm.conf.
 | |
|  
 | |
|  The different events are:
 | |
|  
 | |
| -- 
 | |
| 2.38.1
 | |
| 
 |