We should not use the same name for two different needles even
in two different directories as it can be confusing in some parts
of the UI which don't account for the directory name. Let's use
names differentiated by desktop. Also add a needle for F35 as
the one from the PR doesn't match (different relative placement
of icon and text).
Signed-off-by: Adam Williamson <awilliam@redhat.com>
The PR introduces an improved logic to the desktop_printing.pm
that allows to use the USE_CUPS variable in templates to trigger
the installation of cups-pdf prior to the actual test.
The cups-pdf is then used as an alternative PDF printer
instead the built-in Save As PDF method.
It was removed from the default install:
https://pagure.io/fedora-comps/c/5371509
in favor of a new screenshot mechanism that's built in to GNOME
Shell.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
The latest version of Gnome-Text-Editor bring a little
bit different UI and some new or modified features.
This commit fixes the suite to run on newest version.
Not sure if we lost one with the recent adjustment to the tests
or F35 actually changed somehow, but hey, we need this.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
These needles have been probably forgotten and left over from one
of the previous commits. The tox tests are failing on other
pull requests and this PR fixes it.
Workstation has replaced gedit with gnome-text-editor in Rawhide,
so this is no longer useful. We will replace it with a test suite
for gnome-text-editor.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
Workstation replaced gedit with gnome-text-editor. This updates
the needles and also changes the name used for 'tagging' the
application for the core_applications test.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
Add the download and apply needles (whoops), and tighten the
match area on the update needle a bit so it matches even when
there's a little blue balloon to the left of the text.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
Calculator's equals button changed a bit somehow, EOG changed a
button and the kerning on Activities button changed.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
We get a 96% match on this because the "A" in "Activities" moved
a bit. Instead of a new needle let's just be OK with the lower
match.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
So it doesn't fail if there's a dotted line around the entry
(indicating keyboard active, I think).
Signed-off-by: Adam Williamson <awilliam@redhat.com>
The cross got bigger. This needle might be a dupe with something
but I couldn't be bothered finding it.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
Some changes were made in the icon theme used by the installer
and GNOME, update various needles for this.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
Similar to the 'open' needle, adjust match area to work even
when there's a notification obscuring the top bar.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
We do this slightly differently on KDE and GNOME for whatever
reason, so this needle needs updating too.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
LibreOffice adjusted layout a bit and dropped a template, one
icon changed in the utilities menu compilation.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
Remove a whole chunk of needles that haven't matched for more
than 3 months. Also move a few needles to appropriate locations,
simplify some code chunks that relied on removed needles (if
we're not matching the needles, we don't need those chunks any
more), and drop some other no-longer-needed conditionals for
older releases.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
This adds a test for fingerprint-based login, as requested by
@benzea in #223. We use the fprintd dummy device to let us
simulate scanning a fingerprint, and check various scenarios
recommended by @benzea.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
Now we have two areas, openQA wants to click in the wrong one.
Let's tell it which one to click in.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
The main screen now also has identical "Japanese" (that's what it
says) text. To avoid false matching before the picker opens, add
another match area.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
The open dialog on Silverblue (which is apparently not at all
the same thing as the open dialog on Workstation, though they
look the same) does not default to the Documents folder, so we
have to open it.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
These all failed to match first time the test was run in
production. I guess Lukas was working from an older release.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
This PR fixes issue #188. It adds a test suite to test basic
functionality of Evince and brings the following features:
* test scripts for various Evince functions.
* needles to support the Evince test scripts
* new template variables `TESTPATH` and `POSTINSTALL_LOAD_ALL` (see
below)
* new logic in `main.py` (see below)
The new variables and the new logic make it easier to create test
suites for post-installation tests. If TESTPATH is used, OpenQA
will take all tests mentioned in POSTINSTALL from that specified
TESTPATH. If both TESTPATH and POSTINSTALL_LOAD_ALL are used, then
OpenQA will run all tests it can find at the TESTPATH location.
If POSTINSTALL and POSTINSTALL_LOAD_ALL are set simultaneously,
then only POSTINSTALL will be taken into account and OpenQA will
only load tests mentioned there.
Recent git os-autoinst no longer downsamples screenshots as far
as it did before comparison. This makes a lot of needles where
colors have changed slightly no longer match, so they all needed
updating.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
GNOME dropped the g-i-s new user mode in F34, so on a Japanese
install with user created in the installer, you don't get an
input source configured out of the box or on first boot. So
we'll just have to do it manually after booting, before we test
if it works.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
Not sure why these changed, but oh well. Utilities menu was
highlighted in a test run for some reason, so let's just handle
that. Other needles changed very slightly.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
Some apps moved around, others the needles stopped matching for
some reason, some kind of slight scale change or something.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
The package with the new logo is not submitted as an update yet,
but we ran the tests on the Koji build and these are the new
needles. We'll need more when we run the full set of compose
tests on the change.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
Make the 'deactivate overview if it's active' thing a bit more
robust by asserting the inactive state after deactivating it,
and add new needles for the new RC (text got a bit brighter).
Signed-off-by: Adam Williamson <awilliam@redhat.com>
For consistency, let's just return to the desktop right away. We
also need to handle closing the overview before running installer
on live image boot.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
KDE in F34+ is now placing sleep, restart and shutdown buttons
right on the system menu, not in a submenu. So we need to sort of
tweak this logic. The approach here is: we count the GNOME
submenu as both a "power" and "leave" menu, so the needle to
enter it has both tags. KDE still has a "leave" submenu, but the
power options are not in a submenu any more, so the new "leave"
needle only has the leave tag, not the power tag. For "leave"
actions we just unconditionally expect the "leave" tag; for
power actions we first match on *either* the submenu tag (for
GNOME and earlier KDE) *or* the action tag, click whatever we
found, and then if we matched the submenu (not the action), we
assert and click the action. After that all paths should be in
sync again and we can continue.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
There's a race issue with just treating it as a next button: it's
not in the same place as a next button. Sometimes in the g-i-s
code we actually get ahead of ourselves and click early, which
isn't really a problem when the buttons are all in the same
place, but if we click "Start Setup" in the middle of transition
to the Privacy screen - as in
https://openqa.fedoraproject.org/tests/745034#step/_graphical_wait_login/4
- the click effectively gets lost. So let's make it its own tag
and have the initial assert look for it too. That way we won't
match on it again in the main loop over "@nexts".
Signed-off-by: Adam Williamson <awilliam@redhat.com>
Just matching the Overview entry isn't really enough, the app
hasn't really run yet. This makes the test more robust and also
helps out on aarch64 desktop tests where the app window takes a
long time to appear.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
Even though we have subdirs, we actually usually make needle
names unique across subdirs due to limitations of openQA's UI
upstream.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
In g-i-s 3.37.91, the first screen has a 'Start Setup' button
rather than a 'Next' button. Easiest thing for us to do here is
just to add a new needle which has the 'next_button' tag even
though it's clearly not a 'Next' button, because then the code
still works :) So do that, but give the file a suggestive name
and explain the situation in a code comment.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
GNOME now also splits 'Restart...' and 'Power Off...' as KDE
does, so we need to tweak the conditional and add some needles.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
See https://pagure.io/background-logo-extension/issue/26 - in
current Rawhide, the search box in the overview is not active
when the overview is opened, so you can't just open the
overview and type, you have to click it first.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
Not sure if the needles changed or just the way they're rendered
in the overview, but either way, we need to update a bunch.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
The little triangle that's used on drop-down menus and stuff got
bigger. That breaks all these needles.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
This goes back to when we called this needle desktop_clean, but
there's really no point in having it.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
Since GDM shows the "system-menu-button", it could not correctly
switch users on a locked screen. I added a check to see
if we are on a locked screen and behave accordingly.
This adds a new test that implementsQA:Testcase_desktop_login
on both GNOME and KDE.
While working on this, we realized that the "desktop_clean"
needles were really "app menu" needles, and for KDE, this was
a duplication with the new "system menu" needles, because on KDE
the app menu and the system menu are the same. So I (Adam)
started to de-duplicate that, but also realized that "app menu
button" is a much more accurate name for these needles, so I was
renaming the old desktop_clean needles to app_menu_button. That
led me to the realization that "check_desktop_clean" is itself a
dumb name, because we don't (at least, any more, way back in the
mists of time we may have done) do anything to check that the
desktop is "clean" - we're really just asserting that we're at a
desktop *at all*. While thinking *that* through, I *also* realized
that the whole "open the overview and look for the app grid icon"
workaround it did is no longer necessary, because GNOME doesn't
use a translucent top bar any more. That went away in GNOME 3.32,
which is in Fedora 30, our oldest supported release.
So I threw that away, renamed the function "check_desktop",
cleaned up all the needle naming and tagging, and also added an
app menu needle for GNOME in Japanese because we were missing
one (the Japanese tests have been using the "app grid icon"
workaround the whole time).
I call this...The @lruzicka Catcher!
It's a script that checks for needles that aren't actually used
anywhere. It also checks for cases where we have a needle JSON
file but no image, or an image file but no JSON file (and wipes
one case of the latter). It also adds a run of the script to tox
so we get it in CI.
You could make this script a lot more elaborate if you like, by
being fancier about parsing the test code and templates, but I
don't think it's really warranted, I think it just needs to be
'good enough'. It's not the end of the world if it misses the
odd thing or the whitelisting goes stale.
Quite a lot of the removed needles are remnants of different
approaches to app start/stop testing which weren't caught in the
initial PR review. The short-name partitioning ones are odd; they
were introduced in the commit that moved needles into subdirs,
but at least some of them don't actually appear to be moves. They
may have been non-tracked files Josef had lying around that got
into the commit by mistake, or they may just be old needles we
really used at some point but aren't using any more.
reclaim_space_second_partition was introduced as part of the
shrink test (along with reclaim_space_first_partition) but was
never actually used by that test - I guess, again, the test got
re-written during review but we forgot to remove the needle. We
rejigged user creation to use tab presses not a needle match a
while back, which made user_creation_password_input unnecessary.
The various cockpit_updates_* needles are I think remnants of
rewrites of the cockpit update tests that again were missed in
PR review, the tests as merged never used them.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
Remove a bunch of needles that have not been used for some time,
plus a few workarounds that are similarly stale.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
We still have a 'apps_run_firefox_stop' needle tag which is for
the same thing as 'firefox_close_tabs'. That's dumb. Get rid of
it and only have the firefox_close_tabs tag and needles. Also
clean up some old firefox_close_tabs needles that haven't matched
for months and all the 'apps_run_firefox_stop' needles.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
Seems like there's been a change to freetype or something, text
rendering changed in all of these. Note there's one workaround
needle for an untranslated message in Japanese.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
This is really a 'generic' needle since it'd be needed for any
RTL language test, it's not specific to arabic.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
Mainly because the GDM background became a lighter shade of
grey, for some reason, but also some dialog and icon changes.
Also put all forms of layout_us_ltr-gdm in the same directory.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
Removing this broke the GNOME apps test entirely because there
was no GNOME 'workspace' needle any more.
I don't like this needle much, we should probably use
check_desktop_clean or something instead. But for now let's just
put it back.
Signed-off-by: Adam Williamson <awilliam@redhat.com>
The way KDE does update notifications has changed - it's now a
permanent pop-up notification. This is a bit awkward for our
logic; it's hard to define a needle that proves this pop-up is
the only notification. Instead, let's dismiss it, then open the
notification tray and assert that there aren't any others. But
we also retain the old behaviour (more or less) for testing old
releases.
The popup notification also blocks the 'refresh' needle in the
systray and so breaks the desktop update test, so we deal with
that too.
Signed-off-by: Adam Williamson <awilliam@redhat.com>