stunnel/SOURCES/stunnel-5.50-authpriv.patch
2021-09-10 04:57:41 +00:00

53 lines
2.9 KiB
Diff

diff -up stunnel-5.50/doc/stunnel.8.in.authpriv stunnel-5.50/doc/stunnel.8.in
--- stunnel-5.50/doc/stunnel.8.in.authpriv 2018-12-02 23:47:20.000000000 +0100
+++ stunnel-5.50/doc/stunnel.8.in 2019-01-14 12:15:05.135100163 +0100
@@ -200,7 +200,7 @@ info (6), or debug (7). All logs for th
all levels numerically less than it will be shown. Use \fIdebug = debug\fR or
\&\fIdebug = 7\fR for greatest debugging output. The default is notice (5).
.Sp
-The syslog facility 'daemon' will be used unless a facility name is supplied.
+The syslog facility 'authpriv' will be used unless a facility name is supplied.
(Facilities are not supported on Win32.)
.Sp
Case is ignored for both facilities and levels.
diff -up stunnel-5.50/doc/stunnel.html.in.authpriv stunnel-5.50/doc/stunnel.html.in
--- stunnel-5.50/doc/stunnel.html.in.authpriv 2018-12-02 23:47:21.000000000 +0100
+++ stunnel-5.50/doc/stunnel.html.in 2019-01-14 12:15:05.136100146 +0100
@@ -244,7 +244,7 @@
<p>Level is one of the syslog level names or numbers emerg (0), alert (1), crit (2), err (3), warning (4), notice (5), info (6), or debug (7). All logs for the specified level and all levels numerically less than it will be shown. Use <i>debug = debug</i> or <i>debug = 7</i> for greatest debugging output. The default is notice (5).</p>
-<p>The syslog facility &#39;daemon&#39; will be used unless a facility name is supplied. (Facilities are not supported on Win32.)</p>
+<p>The syslog facility &#39;authpriv&#39; will be used unless a facility name is supplied. (Facilities are not supported on Win32.)</p>
<p>Case is ignored for both facilities and levels.</p>
diff -up stunnel-5.50/doc/stunnel.pod.in.authpriv stunnel-5.50/doc/stunnel.pod.in
--- stunnel-5.50/doc/stunnel.pod.in.authpriv 2018-12-02 23:47:18.000000000 +0100
+++ stunnel-5.50/doc/stunnel.pod.in 2019-01-14 12:15:05.136100146 +0100
@@ -192,7 +192,7 @@ info (6), or debug (7). All logs for th
all levels numerically less than it will be shown. Use I<debug = debug> or
I<debug = 7> for greatest debugging output. The default is notice (5).
-The syslog facility 'daemon' will be used unless a facility name is supplied.
+The syslog facility 'authpriv' will be used unless a facility name is supplied.
(Facilities are not supported on Win32.)
Case is ignored for both facilities and levels.
diff -up stunnel-5.50/src/options.c.authpriv stunnel-5.50/src/options.c
--- stunnel-5.50/src/options.c.authpriv 2019-01-14 12:15:05.136100146 +0100
+++ stunnel-5.50/src/options.c 2019-01-14 12:16:25.537727511 +0100
@@ -1745,8 +1745,12 @@ NOEXPORT char *parse_service_option(CMD
case CMD_SET_DEFAULTS:
section->log_level=LOG_NOTICE;
#if !defined (USE_WIN32) && !defined (__vms)
+#if defined(LOG_AUTHPRIV)
+ new_global_options.log_facility=LOG_AUTHPRIV;
+#else
new_global_options.log_facility=LOG_DAEMON;
#endif
+#endif
break;
case CMD_SET_COPY:
section->log_level=new_service_options.log_level;