avision: add skip-adf option (#1288712)

This commit is contained in:
Nils Philippsen 2017-03-14 17:41:09 +01:00
parent 287950cc56
commit 2ffc2c5c58
2 changed files with 110 additions and 1 deletions

View File

@ -0,0 +1,103 @@
From 2fea21f28ecbcd83ec4c4cf6d1578cdd552b0df4 Mon Sep 17 00:00:00 2001
From: Nils Philippsen <nils@redhat.com>
Date: Tue, 14 Mar 2017 17:38:49 +0100
Subject: [PATCH] patch: avision-skip-adf
Squashed commit of the following:
commit 1177ca9c2673e5264741dff60010ddebaf43737c
Author: Dave Platt <dplatt@radagast.org>
Date: Thu Dec 15 22:29:16 2016 -0800
avision.c: Add "skip-adf" option
The code which tries aggressively to reset/initialize HP 82xx/83xx
Automatic Document Feeders doesn't work well if there's no ADF attached,
because the scanner reports a non-zero ADF model type in this case.
The retry code makes several attempts to initialize the ADF, and then
bails out with an "Operation not supported" error.
Add a new "option skip-adf" which will cause the backend to believe
the "ADF not present" status if that's what the scanner reports.
Fixes #313751
(cherry picked from commit 6585b6f60d07a196e42c99b935e2754bbc80b3c8)
---
backend/avision.c | 14 ++++++++++++--
doc/sane-avision.man | 10 ++++++++++
2 files changed, 22 insertions(+), 2 deletions(-)
diff --git a/backend/avision.c b/backend/avision.c
index 146125c..b02b547 100644
--- a/backend/avision.c
+++ b/backend/avision.c
@@ -1277,6 +1277,9 @@ static SANE_Bool force_calibration = SANE_FALSE;
static SANE_Bool force_a4 = SANE_FALSE;
static SANE_Bool force_a3 = SANE_FALSE;
+/* trust ADF-presence flag, even if ADF model is nonzero */
+static SANE_Bool skip_adf = SANE_FALSE;
+
/* hardware resolutions to interpolate from */
static const int hw_res_list_c5[] =
{
@@ -3218,11 +3221,13 @@ get_accessories_info (Avision_Scanner* s)
{
dev->inquiry_duplex = 1;
dev->inquiry_duplex_interlaced = 0;
- } else if (result[0] == 0 && result[2] != 0) {
+ } else if (result[0] == 0 && result[2] != 0 && !skip_adf) {
/* Sometimes the scanner will report that there is no ADF attached, yet
* an ADF model number will still be reported. This happens on the
* HP8200 series and possibly others. In this case we need to reset the
- * the adf and try reading it again.
+ * the adf and try reading it again. Skip this if the configuration says
+ * to do so, so that we don't fail out the scanner as being broken and
+ * unsupported if there isn't actually an ADF present.
*/
DBG (3, "get_accessories_info: Found ADF model number but the ADF-present flag is not set. Trying to recover...\n");
status = adf_reset (s);
@@ -7630,6 +7635,11 @@ sane_reload_devices (void)
linenumber);
force_a3 = SANE_TRUE;
}
+ else if (strcmp (word, "skip-adf") == 0) {
+ DBG (3, "sane_reload_devices: config file line %d: enabling skip-adf\n",
+ linenumber);
+ skip_adf = SANE_TRUE;
+ }
else if (strcmp (word, "static-red-calib") == 0) {
DBG (3, "sane_reload_devices: config file line %d: static red calibration\n",
linenumber);
diff --git a/doc/sane-avision.man b/doc/sane-avision.man
index 299bb72..6a991b6 100644
--- a/doc/sane-avision.man
+++ b/doc/sane-avision.man
@@ -36,6 +36,7 @@ a hash mark (#) are ignored. A sample configuration file is shown below:
\
option force\-a4
option force\-a3
+ option skip\-adf
option disable\-gamma\-table
option disable\-calibration
\
@@ -61,6 +62,15 @@ known to return bogus data are marked in the backend
so if you need this option please report this to the
backend maintainer. USE WITH CARE!
.TP
+skip\-adf:
+Forces the backend to ignore an inconsistent ADF
+status returned by the scanner (ADF not present, but
+ADF model number non-zero). Without this option, the
+backend will make several attempts to reset the ADF
+and retry the query in this situation, and will fail
+with a "not supported" error if the ADF still doesn't
+respond.
+.TP
disable\-gamma\-table:
Disables the usage of the scanner's gamma-table. You
might try this if your scans hang or only produces
--
2.9.3

View File

@ -33,7 +33,7 @@
Summary: Scanner access software
Name: sane-backends
Version: 1.0.25
Release: 5%{?dist}
Release: 6%{?dist}
# lib/ is LGPLv2+, backends are GPLv2+ with exceptions
# Tools are GPLv2+, docs are public domain
# see LICENSE for details
@ -51,6 +51,8 @@ Patch0: sane-backends-1.0.25-udev.patch
Patch1: sane-backends-1.0.23-soname.patch
# Fedora-specific (for now): make installed sane-config multi-lib aware again
Patch2: sane-backends-1.0.23-sane-config-multilib.patch
# Backported from upstream, commit 6585b6f60d07a196e42c99b935e2754bbc80b3c8
Patch3: sane-backends-1.0.25-avision-skip-adf.patch
URL: http://www.sane-project.org
@ -177,6 +179,7 @@ access image acquisition devices available on the local host.
%patch0 -p1 -b .udev
%patch1 -p1 -b .soname
%patch2 -p1 -b .sane-config-multilib
%patch3 -p1 -b .avision-skip-adf
%build
CFLAGS="%optflags -fno-strict-aliasing"
@ -327,6 +330,9 @@ exit 0
%{_unitdir}/saned@.service
%changelog
* Tue Mar 14 2017 Nils Philippsen <nils@redhat.com> - 1.0.25-6
- avision: add "skip-adf" option (#1288712)
* Sat Feb 11 2017 Fedora Release Engineering <releng@fedoraproject.org> - 1.0.25-5
- Rebuilt for https://fedoraproject.org/wiki/Fedora_26_Mass_Rebuild