import rasdaemon-0.6.1-5.el8
This commit is contained in:
parent
b83f9a4afe
commit
37d270264d
159
SOURCES/add_upstream_labels.patch
Normal file
159
SOURCES/add_upstream_labels.patch
Normal file
@ -0,0 +1,159 @@
|
|||||||
|
---
|
||||||
|
labels/dell | 152 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
||||||
|
1 file changed, 152 insertions(+)
|
||||||
|
|
||||||
|
--- /dev/null 1970-01-01 00:00:00.000000000 +0000
|
||||||
|
+++ rasdaemon-0.6.1/labels/dell 2020-02-20 11:53:39.574579258 -0500
|
||||||
|
@@ -0,0 +1,152 @@
|
||||||
|
+# RASDAEMON Motherboard DIMM labels Database file.
|
||||||
|
+#
|
||||||
|
+# Vendor-name and model-name are found from the program 'dmidecode'
|
||||||
|
+# labels are found from the silk screen on the motherboard.
|
||||||
|
+#
|
||||||
|
+#Vendor: <vendor-name>
|
||||||
|
+# Product: <product-name>
|
||||||
|
+# Model: <model-name>
|
||||||
|
+# <label>: <mc>.<top>.<mid>.<low>
|
||||||
|
+#
|
||||||
|
+
|
||||||
|
+Vendor: Dell Inc.
|
||||||
|
+# 1-socket
|
||||||
|
+ Product: PowerEdge R220, PowerEdge R330, PowerEdge T330, PowerEdge R230, PowerEdge T130, PowerEdge T30
|
||||||
|
+ DIMM_A1: 0.0.0; DIMM_A2: 0.0.1;
|
||||||
|
+ DIMM_A3: 0.1.0; DIMM_A4: 0.1.1;
|
||||||
|
+
|
||||||
|
+ Product: PowerEdge T110 II, PowerEdge T20
|
||||||
|
+ DIMM_A1: 0.0.0; DIMM_A2: 0.1.0;
|
||||||
|
+
|
||||||
|
+ DIMM_B1: 0.0.1; DIMM_B2: 0.1.1;
|
||||||
|
+
|
||||||
|
+ Product: PowerEdge R320, PowerEdge T320
|
||||||
|
+ DIMM_A1: 0.0.0; DIMM_A2: 0.1.0; DIMM_A3: 0.2.0;
|
||||||
|
+ DIMM_A4: 0.0.1; DIMM_A5: 0.1.1; DIMM_A6: 0.2.1;
|
||||||
|
+
|
||||||
|
+# 2-socket
|
||||||
|
+ Product: PowerEdge R610
|
||||||
|
+ DIMM_A1: 0.0.0; DIMM_A2: 0.0.1; DIMM_A3: 0.0.2;
|
||||||
|
+ DIMM_A4: 0.1.0; DIMM_A5: 0.1.1; DIMM_A6: 0.1.2;
|
||||||
|
+
|
||||||
|
+ DIMM_B1: 1.0.0; DIMM_B2: 1.0.1; DIMM_B3: 1.0.2;
|
||||||
|
+ DIMM_B4: 1.1.0; DIMM_B5: 1.1.1; DIMM_B6: 1.1.2;
|
||||||
|
+
|
||||||
|
+ Product: PowerEdge T710, PowerEdge R710
|
||||||
|
+ DIMM_A3: 0.0.0; DIMM_A2: 0.1.0; DIMM_A1: 0.2.0;
|
||||||
|
+ DIMM_A6: 0.0.1; DIMM_A5: 0.1.1; DIMM_A4: 0.2.1;
|
||||||
|
+ DIMM_A9: 0.0.2; DIMM_A8: 0.1.2; DIMM_A7: 0.2.2;
|
||||||
|
+
|
||||||
|
+ DIMM_B3: 1.0.0; DIMM_B2: 1.1.0; DIMM_B1: 1.2.0;
|
||||||
|
+ DIMM_B6: 1.0.1; DIMM_B5: 1.1.1; DIMM_B4: 1.2.1;
|
||||||
|
+ DIMM_B9: 1.0.2; DIMM_B8: 1.1.2; DIMM_B7: 1.2.2;
|
||||||
|
+
|
||||||
|
+ Product: PowerEdge R620, PowerEdge T620, PowerEdge R720xd, PowerEdge R730xd, PowerEdge T630, PowerEdge R730, PowerEdge R630, PowerEdge T620, PowerEdge M620, PowerEdge FC620, PowerEdge M630, PowerEdge FC630
|
||||||
|
+ DIMM_A1: 0.0.0; DIMM_A2: 0.1.0; DIMM_A3: 0.2.0; DIMM_A4: 0.3.0;
|
||||||
|
+ DIMM_A5: 0.0.1; DIMM_A6: 0.1.1; DIMM_A7: 0.2.1; DIMM_A8: 0.3.1;
|
||||||
|
+ DIMM_A9: 0.0.2; DIMM_A10: 0.1.2; DIMM_A11: 0.2.2; DIMM_A12: 0.3.2;
|
||||||
|
+
|
||||||
|
+ DIMM_B1: 1.0.0; DIMM_B2: 1.1.0; DIMM_B3: 1.2.0; DIMM_B4: 1.3.0;
|
||||||
|
+ DIMM_B5: 1.0.1; DIMM_B6: 1.1.1; DIMM_B7: 1.2.1; DIMM_B8: 1.3.1;
|
||||||
|
+ DIMM_B9: 1.0.2; DIMM_B10: 1.1.2; DIMM_B11: 1.2.2; DIMM_B12: 1.3.2;
|
||||||
|
+
|
||||||
|
+ Product: PowerEdge R640, PowerEdge R740, PowerEdge R740xd, PowerEdge T640
|
||||||
|
+ A1: 0.0.0; A2: 0.1.0; A3: 0.2.0; A4: 1.0.0; A5: 1.1.0; A6: 1.2.0;
|
||||||
|
+ A7: 0.0.1; A8: 0.1.1; A9: 0.2.1; A10: 1.0.1; A11: 1.1.1; A12: 1.2.1;
|
||||||
|
+
|
||||||
|
+ B1: 2.0.0; B2: 2.1.0; B3: 2.2.0; B4: 3.0.0; B5: 3.1.0; B6: 3.2.0;
|
||||||
|
+ B7: 2.0.1; B8: 2.1.1; B9: 2.2.1; B10: 3.0.1; B11: 3.1.1; B12: 3.2.1;
|
||||||
|
+
|
||||||
|
+ Product: PowerEdge M520, PowerEdge R420, PowerEdge T420
|
||||||
|
+ DIMM_A1: 0.1.0; DIMM_A2: 0.2.0; DIMM_A3: 0.3.0;
|
||||||
|
+ DIMM_A4: 0.1.1; DIMM_A5: 0.2.1; DIMM_A6: 0.3.1;
|
||||||
|
+
|
||||||
|
+ DIMM_B1: 1.1.0; DIMM_B2: 1.2.0; DIMM_B3: 1.3.0;
|
||||||
|
+ DIMM_B4: 1.1.1; DIMM_B5: 1.2.1; DIMM_B6: 1.3.1;
|
||||||
|
+
|
||||||
|
+ Product: PowerEdge FC420, PowerEdge M420
|
||||||
|
+ DIMM_A1: 0.0.0; DIMM_A2: 0.1.0; DIMM_A3: 0.2.0;
|
||||||
|
+
|
||||||
|
+ DIMM_B1: 1.0.0; DIMM_B2: 1.1.0; DIMM_B3: 1.2.0;
|
||||||
|
+
|
||||||
|
+ Product: PowerEdge C6320, PowerEdge C4130
|
||||||
|
+ DIMM_A1: 0.0.0; DIMM_A2: 0.1.0; DIMM_A3: 0.2.0; DIMM_A4: 0.3.0;
|
||||||
|
+ DIMM_A5: 0.0.1; DIMM_A6: 0.1.1; DIMM_A7: 0.2.1; DIMM_A8: 0.3.1;
|
||||||
|
+
|
||||||
|
+ DIMM_B1: 1.0.0; DIMM_B2: 1.1.0; DIMM_B3: 1.2.0; DIMM_B4: 1.3.0;
|
||||||
|
+ DIMM_B5: 1.0.1; DIMM_B6: 1.1.1; DIMM_B7: 1.2.1; DIMM_B8: 1.3.1;
|
||||||
|
+
|
||||||
|
+ Product: PowerEdge C6320p
|
||||||
|
+ A1: 0.0.0; B1: 0.1.0; C1: 0.2.0;
|
||||||
|
+ D1: 1.0.0; E1: 1.1.0; F1: 1.2.0;
|
||||||
|
+
|
||||||
|
+ Product: PowerEdge C6420
|
||||||
|
+ A1: 0.0.0; A2: 0.1.0; A3: 0.2.0; A4: 1.0.0; A5: 1.1.0; A6: 1.2.0;
|
||||||
|
+ A7: 0.0.1; A8: 1.0.1;
|
||||||
|
+
|
||||||
|
+ B1: 2.0.0; B2: 2.1.0; B3: 2.2.0; B4: 3.0.0; B5: 3.1.0; B6: 3.2.0;
|
||||||
|
+ B7: 2.0.1; B8: 3.0.1;
|
||||||
|
+
|
||||||
|
+ Product: PowerEdge R430, PowerEdge T430, PowerEdge R530
|
||||||
|
+ DIMM_A1: 0.0.0; DIMM_A2: 0.1.0; DIMM_A3: 0.2.0; DIMM_A4: 0.3.0;
|
||||||
|
+ DIMM_A5: 0.0.1; DIMM_A6: 0.1.1; DIMM_A7: 0.2.1; DIMM_A8: 0.3.1;
|
||||||
|
+
|
||||||
|
+ DIMM_B1: 1.0.0; DIMM_B2: 1.1.0; DIMM_B3: 1.2.0; DIMM_B4: 1.3.0;
|
||||||
|
+
|
||||||
|
+ Product: PowerEdge FC430
|
||||||
|
+ DIMM_A1: 0.1.0; DIMM_A2: 0.0.0; DIMM_A3: 0.2.0; DIMM_A4: 0.3.0;
|
||||||
|
+
|
||||||
|
+ DIMM_B1: 1.1.0; DIMM_B2: 1.0.0; DIMM_B3: 1.2.0; DIMM_B4: 1.3.0;
|
||||||
|
+
|
||||||
|
+# 4-socket
|
||||||
|
+ Product: PowerEdge M820, PowerEdge R830, PowerEdge M830, PowerEdge R930, PowerEdge FC830
|
||||||
|
+ DIMM_A1: 0.0.0; DIMM_A2: 0.1.0; DIMM_A3: 0.2.0; DIMM_A4: 0.3.0;
|
||||||
|
+ DIMM_A5: 0.0.1; DIMM_A6: 0.1.1; DIMM_A7: 0.2.1; DIMM_A8: 0.3.1;
|
||||||
|
+ DIMM_A9: 0.0.2; DIMM_A10: 0.1.2; DIMM_A11: 0.2.2; DIMM_A12: 0.3.2;
|
||||||
|
+
|
||||||
|
+ DIMM_B1: 1.0.0; DIMM_B2: 1.1.0; DIMM_B3: 1.2.0; DIMM_B4: 1.3.0;
|
||||||
|
+ DIMM_B5: 1.0.1; DIMM_B6: 1.1.1; DIMM_B7: 1.2.1; DIMM_B8: 1.3.1;
|
||||||
|
+ DIMM_B9: 1.0.2; DIMM_B10: 1.1.2; DIMM_B11: 1.2.2; DIMM_B12: 1.3.2;
|
||||||
|
+
|
||||||
|
+ DIMM_C1: 2.0.0; DIMM_C2: 2.1.0; DIMM_C3: 2.2.0; DIMM_C4: 2.3.0;
|
||||||
|
+ DIMM_C5: 2.0.1; DIMM_C6: 2.1.1; DIMM_C7: 2.2.1; DIMM_C8: 2.3.1;
|
||||||
|
+ DIMM_C9: 2.0.2; DIMM_C10: 2.1.2; DIMM_C11: 2.2.2; DIMM_C12: 2.3.2;
|
||||||
|
+
|
||||||
|
+ DIMM_D1: 3.0.0; DIMM_D2: 3.1.0; DIMM_D3: 3.2.0; DIMM_D4: 3.3.0;
|
||||||
|
+ DIMM_D5: 3.0.1; DIMM_D6: 3.1.1; DIMM_D7: 3.2.1; DIMM_D8: 3.3.1;
|
||||||
|
+ DIMM_D9: 3.0.2; DIMM_D10: 3.1.2; DIMM_D11: 3.2.2; DIMM_D12: 3.3.2;
|
||||||
|
+
|
||||||
|
+ Product: PowerEdge FM120x4
|
||||||
|
+ DIMM_A_A1: 0.1.0; DIMM_A_A2: 0.2.0;
|
||||||
|
+
|
||||||
|
+ DIMM_B_A1: 1.1.0; DIMM_B_A2: 1.2.0;
|
||||||
|
+
|
||||||
|
+ DIMM_C_A1: 2.1.0; DIMM_C_A2: 2.2.0;
|
||||||
|
+
|
||||||
|
+ DIMM_D_A1: 3.1.0; DIMM_D_A2: 3.2.0;
|
||||||
|
+
|
||||||
|
+ Product: PowerEdge R940
|
||||||
|
+ A1: 0.0.0; A2: 0.1.0; A3: 0.2.0; A4: 1.0.0; A5: 1.1.0; A6: 1.2.0;
|
||||||
|
+ A7: 0.0.1; A8: 0.1.1; A9: 0.2.1; A10: 1.0.1; A11: 1.1.1; A12: 1.2.1;
|
||||||
|
+
|
||||||
|
+ B1: 2.0.0; B2: 2.1.0; B3: 2.2.0; B4: 3.0.0; B5: 3.1.0; B6: 3.2.0;
|
||||||
|
+ B7: 2.0.1; B8: 2.1.1; B9: 2.2.1; B10: 3.0.1; B11: 3.1.1; B12: 3.2.1;
|
||||||
|
+
|
||||||
|
+ C1: 4.0.0; C2: 4.1.0; C3: 4.2.0; C4: 5.0.0; C5: 5.1.0; C6: 5.2.0;
|
||||||
|
+ C7: 4.0.1; C8: 4.1.1; C9: 4.2.1; C10: 5.0.1; C11: 5.1.1; C12: 5.2.1;
|
||||||
|
+
|
||||||
|
+ D1: 6.0.0; D2: 6.1.0; D3: 6.2.0; D4: 7.0.0; D5: 7.1.0; D6: 7.2.0;
|
||||||
|
+ D7: 6.0.1; D8: 6.1.1; D9: 6.2.1; D10: 7.0.1; D11: 7.1.1; D12: 7.2.1;
|
||||||
|
+
|
||||||
|
+ Product: PowerEdge R440, PowerEdge R540
|
||||||
|
+ A1: 0.0.0; A2: 0.1.0; A3: 0.2.0; A4: 1.0.0; A5: 1.1.0; A6: 1.2.0;
|
||||||
|
+ A7: 0.0.1; A8: 0.1.1; A9: 1.0.1; A10: 1.1.1;
|
||||||
|
+
|
||||||
|
+ B1: 2.0.0; B2: 2.1.0; B3: 2.2.0; B4: 3.0.0; B5: 3.1.0; B6: 3.2.0;
|
||||||
|
+
|
||||||
|
+ Product: PowerEdge M640, PowerEdge FC640
|
||||||
|
+ A1: 0.0.0; A2: 0.1.0; A3: 0.2.0; A4: 1.0.0; A5: 1.1.0; A6: 1.2.0;
|
||||||
|
+ A7: 0.0.1; A8: 1.0.1;
|
||||||
|
+
|
||||||
|
+ B1: 2.0.0; B2: 2.1.0; B3: 2.2.0; B4: 3.0.0; B5: 3.1.0; B6: 3.2.0;
|
||||||
|
+ B7: 2.0.1; B8: 3.0.1;
|
37
SOURCES/b22be68453b2497e86cbd273b9cd56fadc5859e3.patch
Normal file
37
SOURCES/b22be68453b2497e86cbd273b9cd56fadc5859e3.patch
Normal file
@ -0,0 +1,37 @@
|
|||||||
|
commit b22be68453b2497e86cbd273b9cd56fadc5859e3
|
||||||
|
Author: Ying Lv <lvying6@huawei.com>
|
||||||
|
Date: Wed May 15 11:15:42 2019 +0800
|
||||||
|
|
||||||
|
fix rasdaemon high CPU usage when part of CPUs offline
|
||||||
|
|
||||||
|
When we set part of CPU core offline, such as by setting the kernel cmdline
|
||||||
|
maxcpus = N(N is less than the total number of system CPU cores).
|
||||||
|
And then, we will observe that the CPU usage of some rasdaemon threads
|
||||||
|
is very close to 100.
|
||||||
|
|
||||||
|
This is because when part of CPU offline, poll in read_ras_event_all_cpus func
|
||||||
|
will fallback to pthread way.
|
||||||
|
Offlined CPU thread will return negative value when read trace_pipe_raw,
|
||||||
|
negative return value will covert to positive value because of 'unsigned size'.
|
||||||
|
So code will always go into 'size > 0' branch, and the CPU usage is too high.
|
||||||
|
|
||||||
|
Here, variable size uses int type will go to the right branch.
|
||||||
|
|
||||||
|
Fiexs: eff7c9e0("ras-events: Only use pthreads for collect if poll() not available")
|
||||||
|
Reported-by: Zhipeng Xie <xiezhipeng1@huawei.com>
|
||||||
|
Signed-off-by: Ying Lv <lvying6@huawei.com>
|
||||||
|
Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@kernel.org>
|
||||||
|
|
||||||
|
diff --git a/ras-events.c b/ras-events.c
|
||||||
|
index 4e7b815..38ebe1e 100644
|
||||||
|
--- a/ras-events.c
|
||||||
|
+++ b/ras-events.c
|
||||||
|
@@ -426,7 +426,7 @@ static int read_ras_event(int fd,
|
||||||
|
struct kbuffer *kbuf,
|
||||||
|
void *page)
|
||||||
|
{
|
||||||
|
- unsigned size;
|
||||||
|
+ int size;
|
||||||
|
unsigned long long time_stamp;
|
||||||
|
void *data;
|
||||||
|
|
@ -1,6 +1,6 @@
|
|||||||
Name: rasdaemon
|
Name: rasdaemon
|
||||||
Version: 0.6.1
|
Version: 0.6.1
|
||||||
Release: 3%{?dist}
|
Release: 5%{?dist}
|
||||||
Summary: Utility to receive RAS error tracings
|
Summary: Utility to receive RAS error tracings
|
||||||
Group: Applications/System
|
Group: Applications/System
|
||||||
License: GPLv2
|
License: GPLv2
|
||||||
@ -25,6 +25,8 @@ Requires(postun): systemd
|
|||||||
|
|
||||||
Patch1: 60a91e4da4f2daf2b10143fc148a8043312b61e5.patch
|
Patch1: 60a91e4da4f2daf2b10143fc148a8043312b61e5.patch
|
||||||
Patch2: a16ca0711001957ee98f2c124abce0fa1f801529.patch
|
Patch2: a16ca0711001957ee98f2c124abce0fa1f801529.patch
|
||||||
|
Patch3: add_upstream_labels.patch
|
||||||
|
Patch4: b22be68453b2497e86cbd273b9cd56fadc5859e3.patch
|
||||||
|
|
||||||
%description
|
%description
|
||||||
%{name} is a RAS (Reliability, Availability and Serviceability) logging tool.
|
%{name} is a RAS (Reliability, Availability and Serviceability) logging tool.
|
||||||
@ -40,6 +42,8 @@ an utility for reporting current error counts from the EDAC sysfs files.
|
|||||||
%setup -q
|
%setup -q
|
||||||
%patch1 -p1
|
%patch1 -p1
|
||||||
%patch2 -p1
|
%patch2 -p1
|
||||||
|
%patch3 -p1
|
||||||
|
%patch4 -p1
|
||||||
|
|
||||||
%build
|
%build
|
||||||
%ifarch %{arm} aarch64
|
%ifarch %{arm} aarch64
|
||||||
@ -53,6 +57,7 @@ make %{?_smp_mflags}
|
|||||||
make install DESTDIR=%{buildroot}
|
make install DESTDIR=%{buildroot}
|
||||||
install -D -p -m 0644 misc/rasdaemon.service %{buildroot}/%{_unitdir}/rasdaemon.service
|
install -D -p -m 0644 misc/rasdaemon.service %{buildroot}/%{_unitdir}/rasdaemon.service
|
||||||
install -D -p -m 0644 misc/ras-mc-ctl.service %{buildroot}%{_unitdir}/ras-mc-ctl.service
|
install -D -p -m 0644 misc/ras-mc-ctl.service %{buildroot}%{_unitdir}/ras-mc-ctl.service
|
||||||
|
install -D -p -m 0655 labels/* %{buildroot}%{_sysconfdir}/ras/dimm_labels.d
|
||||||
rm INSTALL %{buildroot}/usr/include/*.h
|
rm INSTALL %{buildroot}/usr/include/*.h
|
||||||
|
|
||||||
%files
|
%files
|
||||||
@ -65,6 +70,12 @@ rm INSTALL %{buildroot}/usr/include/*.h
|
|||||||
%{_sysconfdir}/ras/dimm_labels.d
|
%{_sysconfdir}/ras/dimm_labels.d
|
||||||
|
|
||||||
%changelog
|
%changelog
|
||||||
|
* Wed Apr 08 2020 Aristeu Rozanski <aris@redhat.com> 0.6.1-5
|
||||||
|
- Fix high CPU usage when CPUs are offline [1683420]
|
||||||
|
|
||||||
|
* Wed Apr 08 2020 Aristeu Rozanski <aris@redhat.com> 0.6.1-4
|
||||||
|
- Include upstream labels [1665418]
|
||||||
|
|
||||||
* Thu Jul 11 2019 Aristeu Rozanski <aris@redhat.com> 0.6.1-3
|
* Thu Jul 11 2019 Aristeu Rozanski <aris@redhat.com> 0.6.1-3
|
||||||
- Add support for AMD scalable MCA [1725488]
|
- Add support for AMD scalable MCA [1725488]
|
||||||
|
|
||||||
|
Loading…
Reference in New Issue
Block a user