import python-blivet-3.4.0-13.el8
This commit is contained in:
parent
d3748df227
commit
35ccb031bc
@ -0,0 +1,29 @@
|
||||
From a15c65a5e71f6fd53624bd657ab95b38d37c6f1b Mon Sep 17 00:00:00 2001
|
||||
From: Vojtech Trefny <vtrefny@redhat.com>
|
||||
Date: Mon, 16 Aug 2021 09:50:34 +0200
|
||||
Subject: [PATCH] Fix getting PV info in LVMPhysicalVolume from the cache
|
||||
|
||||
"self.device" is string for formats so accessing "self.device.path"
|
||||
results in an AttributeError.
|
||||
|
||||
Resolves: rhbz#2079220
|
||||
---
|
||||
blivet/formats/lvmpv.py | 2 +-
|
||||
1 file changed, 1 insertion(+), 1 deletion(-)
|
||||
|
||||
diff --git a/blivet/formats/lvmpv.py b/blivet/formats/lvmpv.py
|
||||
index e4182adb..8cfade9f 100644
|
||||
--- a/blivet/formats/lvmpv.py
|
||||
+++ b/blivet/formats/lvmpv.py
|
||||
@@ -170,7 +170,7 @@ class LVMPhysicalVolume(DeviceFormat):
|
||||
if self.exists:
|
||||
# we don't have any actual value, but the PV exists and is
|
||||
# active, we should try to determine it
|
||||
- pv_info = pvs_info.cache.get(self.device.path)
|
||||
+ pv_info = pvs_info.cache.get(self.device)
|
||||
if pv_info is None:
|
||||
log.error("Failed to get free space information for the PV '%s'", self.device)
|
||||
self._free = Size(0)
|
||||
--
|
||||
2.35.3
|
||||
|
@ -0,0 +1,41 @@
|
||||
From 78eda3d74110dbf9669c3271f7d2fddf962d0381 Mon Sep 17 00:00:00 2001
|
||||
From: Vojtech Trefny <vtrefny@redhat.com>
|
||||
Date: Thu, 28 Apr 2022 14:13:04 +0200
|
||||
Subject: [PATCH] Do not crash when changing disklabel on disks with active
|
||||
devices
|
||||
|
||||
The _find_active_devices_on_action_disks function originally
|
||||
prevented from making any changes on disks with active devices
|
||||
(active LVs, mounted partitions etc.) This was changed in
|
||||
b72e957d2b23444824316331ae21d1c594371e9c and the check currently
|
||||
prevents only reformatting the disklabel on such disks which
|
||||
should be already impossible on disks with an existing partition.
|
||||
|
||||
This change for the 3.4 stable branch keeps the current behaviour
|
||||
where the active devices are teared down when running in installer
|
||||
mode to avoid potential issues with the installer.
|
||||
|
||||
Resolves: rhbz#2078801
|
||||
---
|
||||
blivet/actionlist.py | 5 ++---
|
||||
1 file changed, 2 insertions(+), 3 deletions(-)
|
||||
|
||||
diff --git a/blivet/actionlist.py b/blivet/actionlist.py
|
||||
index d03e32b9..4ec2dbf8 100644
|
||||
--- a/blivet/actionlist.py
|
||||
+++ b/blivet/actionlist.py
|
||||
@@ -211,9 +211,8 @@ class ActionList(object):
|
||||
except StorageError as e:
|
||||
log.info("teardown of %s failed: %s", device.name, e)
|
||||
else:
|
||||
- raise RuntimeError("partitions in use on disks with changes "
|
||||
- "pending: %s" %
|
||||
- ",".join(problematic))
|
||||
+ log.debug("ignoring devices in use on disks with changes: %s",
|
||||
+ ",".join(problematic))
|
||||
|
||||
log.info("resetting parted disks...")
|
||||
for device in devices:
|
||||
--
|
||||
2.35.3
|
||||
|
@ -0,0 +1,65 @@
|
||||
From 950f51a4cc041fe1b8a98b17e4828857b7423e55 Mon Sep 17 00:00:00 2001
|
||||
From: Vojtech Trefny <vtrefny@redhat.com>
|
||||
Date: Wed, 13 Apr 2022 15:43:45 +0200
|
||||
Subject: [PATCH] ActionDestroyDevice should not obsolete ActionRemoveMember
|
||||
|
||||
If we want to remove a PV from a VG and then remove the PV device,
|
||||
the ActionDestroyDevice must not obsolete the ActionRemoveMember
|
||||
action. Eventhough we are going to remove the device, we still
|
||||
need to call "vgreduce" first.
|
||||
|
||||
Resolves: rhbz#2076958
|
||||
---
|
||||
blivet/deviceaction.py | 10 +++++-----
|
||||
tests/action_test.py | 7 +++++++
|
||||
2 files changed, 12 insertions(+), 5 deletions(-)
|
||||
|
||||
diff --git a/blivet/deviceaction.py b/blivet/deviceaction.py
|
||||
index 0458e4be..78e113bf 100644
|
||||
--- a/blivet/deviceaction.py
|
||||
+++ b/blivet/deviceaction.py
|
||||
@@ -463,8 +463,8 @@ class ActionDestroyDevice(DeviceAction):
|
||||
- obsoletes all actions w/ lower id that act on the same device,
|
||||
including self, if device does not exist
|
||||
|
||||
- - obsoletes all but ActionDestroyFormat actions w/ lower id on the
|
||||
- same device if device exists
|
||||
+ - obsoletes all but ActionDestroyFormat and ActionRemoveMember actions
|
||||
+ w/ lower id on the same device if device exists
|
||||
|
||||
- obsoletes all actions that add a member to this action's
|
||||
(container) device
|
||||
@@ -474,9 +474,9 @@ class ActionDestroyDevice(DeviceAction):
|
||||
if action.device.id == self.device.id:
|
||||
if self.id >= action.id and not self.device.exists:
|
||||
rc = True
|
||||
- elif self.id > action.id and \
|
||||
- self.device.exists and \
|
||||
- not (action.is_destroy and action.is_format):
|
||||
+ elif self.id > action.id and self.device.exists and \
|
||||
+ not ((action.is_destroy and action.is_format) or
|
||||
+ action.is_remove):
|
||||
rc = True
|
||||
elif action.is_add and (action.device == self.device):
|
||||
rc = True
|
||||
diff --git a/tests/action_test.py b/tests/action_test.py
|
||||
index 1e84c20b..b3608047 100644
|
||||
--- a/tests/action_test.py
|
||||
+++ b/tests/action_test.py
|
||||
@@ -1198,6 +1198,13 @@ class DeviceActionTestCase(StorageTestCase):
|
||||
self.assertEqual(create_sdc2.requires(remove_sdc1), False)
|
||||
self.assertEqual(remove_sdc1.requires(create_sdc2), False)
|
||||
|
||||
+ # destroy sdc1, the ActionRemoveMember should not be obsoleted
|
||||
+ sdc1.exists = True
|
||||
+ destroy_sdc1 = ActionDestroyDevice(sdc1)
|
||||
+ destroy_sdc1.apply()
|
||||
+ self.assertFalse(destroy_sdc1.obsoletes(remove_sdc1))
|
||||
+ self.assertTrue(destroy_sdc1.requires(remove_sdc1))
|
||||
+
|
||||
def test_action_sorting(self, *args, **kwargs):
|
||||
""" Verify correct functioning of action sorting. """
|
||||
|
||||
--
|
||||
2.35.3
|
||||
|
@ -0,0 +1,63 @@
|
||||
From a9cb01f948fa5371b3e6f9282e7af81aec5cb1a8 Mon Sep 17 00:00:00 2001
|
||||
From: Vojtech Trefny <vtrefny@redhat.com>
|
||||
Date: Mon, 2 May 2022 15:30:16 +0200
|
||||
Subject: [PATCH] Correctly set vg_name after adding/removing a PV from a VG
|
||||
|
||||
Without setting the LVMPhysicalVolume.vg_name argument to None
|
||||
after removing the PV from its VG, the PV is still considered
|
||||
active and cannot be removed.
|
||||
|
||||
Resolves: rhbz#2081276
|
||||
---
|
||||
blivet/devices/lvm.py | 3 +++
|
||||
tests/devices_test/lvm_test.py | 13 +++++++++++++
|
||||
2 files changed, 16 insertions(+)
|
||||
|
||||
diff --git a/blivet/devices/lvm.py b/blivet/devices/lvm.py
|
||||
index c61eeb4b..7c78c813 100644
|
||||
--- a/blivet/devices/lvm.py
|
||||
+++ b/blivet/devices/lvm.py
|
||||
@@ -385,6 +385,8 @@ class LVMVolumeGroupDevice(ContainerDevice):
|
||||
if not parent.format.exists:
|
||||
parent.format.free = self._get_pv_usable_space(parent)
|
||||
|
||||
+ parent.format.vg_name = self.name
|
||||
+
|
||||
def _remove_parent(self, parent):
|
||||
# XXX It would be nice to raise an exception if removing this member
|
||||
# would not leave enough space, but the devicefactory relies on it
|
||||
@@ -395,6 +397,7 @@ class LVMVolumeGroupDevice(ContainerDevice):
|
||||
super(LVMVolumeGroupDevice, self)._remove_parent(parent)
|
||||
parent.format.free = None
|
||||
parent.format.container_uuid = None
|
||||
+ parent.format.vg_name = None
|
||||
|
||||
# We can't rely on lvm to tell us about our size, free space, &c
|
||||
# since we could have modifications queued, unless the VG and all of
|
||||
diff --git a/tests/devices_test/lvm_test.py b/tests/devices_test/lvm_test.py
|
||||
index 336c5b99..c349f003 100644
|
||||
--- a/tests/devices_test/lvm_test.py
|
||||
+++ b/tests/devices_test/lvm_test.py
|
||||
@@ -453,6 +453,19 @@ class LVMDeviceTest(unittest.TestCase):
|
||||
pool.autoset_md_size(enforced=True)
|
||||
self.assertEqual(pool.chunk_size, Size("128 KiB"))
|
||||
|
||||
+ def test_add_remove_pv(self):
|
||||
+ pv1 = StorageDevice("pv1", fmt=blivet.formats.get_format("lvmpv"),
|
||||
+ size=Size("1024 MiB"))
|
||||
+ pv2 = StorageDevice("pv2", fmt=blivet.formats.get_format("lvmpv"),
|
||||
+ size=Size("1024 MiB"))
|
||||
+ vg = LVMVolumeGroupDevice("testvg", parents=[pv1])
|
||||
+
|
||||
+ vg._add_parent(pv2)
|
||||
+ self.assertEqual(pv2.format.vg_name, vg.name)
|
||||
+
|
||||
+ vg._remove_parent(pv2)
|
||||
+ self.assertEqual(pv2.format.vg_name, None)
|
||||
+
|
||||
|
||||
class TypeSpecificCallsTest(unittest.TestCase):
|
||||
def test_type_specific_calls(self):
|
||||
--
|
||||
2.35.3
|
||||
|
@ -0,0 +1,29 @@
|
||||
From 6d1bc8ae0cee4ee837d5dc8ad7f1a525208f3eec Mon Sep 17 00:00:00 2001
|
||||
From: Vojtech Trefny <vtrefny@redhat.com>
|
||||
Date: Thu, 5 May 2022 16:35:37 +0200
|
||||
Subject: [PATCH] Use LVM PV format current_size in
|
||||
LVMVolumeGroupDevice._remove
|
||||
|
||||
The member format size is 0 when target size is not set.
|
||||
|
||||
Related: rhbz#2081276
|
||||
---
|
||||
blivet/devices/lvm.py | 2 +-
|
||||
1 file changed, 1 insertion(+), 1 deletion(-)
|
||||
|
||||
diff --git a/blivet/devices/lvm.py b/blivet/devices/lvm.py
|
||||
index 7c78c813..4700d141 100644
|
||||
--- a/blivet/devices/lvm.py
|
||||
+++ b/blivet/devices/lvm.py
|
||||
@@ -293,7 +293,7 @@ class LVMVolumeGroupDevice(ContainerDevice):
|
||||
|
||||
# do not run pvmove on empty PVs
|
||||
member.format.update_size_info()
|
||||
- if member.format.free < member.format.size:
|
||||
+ if member.format.free < member.format.current_size:
|
||||
blockdev.lvm.pvmove(member.path)
|
||||
blockdev.lvm.vgreduce(self.name, member.path)
|
||||
|
||||
--
|
||||
2.35.3
|
||||
|
588
SOURCES/0018-Add-support-for-creating-LVM-cache-pools.patch
Normal file
588
SOURCES/0018-Add-support-for-creating-LVM-cache-pools.patch
Normal file
@ -0,0 +1,588 @@
|
||||
From 91e443af7b9f6b8d7f845f353a3897e3c91015b3 Mon Sep 17 00:00:00 2001
|
||||
From: Vojtech Trefny <vtrefny@redhat.com>
|
||||
Date: Thu, 30 Dec 2021 16:08:43 +0100
|
||||
Subject: [PATCH 1/4] Add support for creating LVM cache pools
|
||||
|
||||
Resolves: rhbz#2055198
|
||||
---
|
||||
blivet/blivet.py | 9 +-
|
||||
blivet/devicelibs/lvm.py | 9 ++
|
||||
blivet/devices/lvm.py | 160 +++++++++++++++++++++++++++++++--
|
||||
tests/devices_test/lvm_test.py | 26 ++++++
|
||||
4 files changed, 196 insertions(+), 8 deletions(-)
|
||||
|
||||
diff --git a/blivet/blivet.py b/blivet/blivet.py
|
||||
index c6908eb0..d29fadd0 100644
|
||||
--- a/blivet/blivet.py
|
||||
+++ b/blivet/blivet.py
|
||||
@@ -576,6 +576,8 @@ class Blivet(object):
|
||||
:type vdo_pool: bool
|
||||
:keyword vdo_lv: whether to create a vdo lv
|
||||
:type vdo_lv: bool
|
||||
+ :keyword cache_pool: whether to create a cache pool
|
||||
+ :type cache_pool: bool
|
||||
:returns: the new device
|
||||
:rtype: :class:`~.devices.LVMLogicalVolumeDevice`
|
||||
|
||||
@@ -594,6 +596,7 @@ class Blivet(object):
|
||||
thin_pool = kwargs.pop("thin_pool", False)
|
||||
vdo_pool = kwargs.pop("vdo_pool", False)
|
||||
vdo_lv = kwargs.pop("vdo_lv", False)
|
||||
+ cache_pool = kwargs.pop("cache_pool", False)
|
||||
parent = kwargs.get("parents", [None])[0]
|
||||
if (thin_volume or vdo_lv) and parent:
|
||||
# kwargs["parents"] will contain the pool device, so...
|
||||
@@ -609,6 +612,8 @@ class Blivet(object):
|
||||
kwargs["seg_type"] = "vdo-pool"
|
||||
if vdo_lv:
|
||||
kwargs["seg_type"] = "vdo"
|
||||
+ if cache_pool:
|
||||
+ kwargs["seg_type"] = "cache-pool"
|
||||
|
||||
mountpoint = kwargs.pop("mountpoint", None)
|
||||
if 'fmt_type' in kwargs:
|
||||
@@ -640,7 +645,7 @@ class Blivet(object):
|
||||
swap = False
|
||||
|
||||
prefix = ""
|
||||
- if thin_pool or vdo_pool:
|
||||
+ if thin_pool or vdo_pool or cache_pool:
|
||||
prefix = "pool"
|
||||
|
||||
name = self.suggest_device_name(parent=vg,
|
||||
@@ -651,7 +656,7 @@ class Blivet(object):
|
||||
if "%s-%s" % (vg.name, name) in self.names:
|
||||
raise ValueError("name '%s' is already in use" % name)
|
||||
|
||||
- if thin_pool or thin_volume or vdo_pool or vdo_lv:
|
||||
+ if thin_pool or thin_volume or vdo_pool or vdo_lv or cache_pool:
|
||||
cache_req = kwargs.pop("cache_request", None)
|
||||
if cache_req:
|
||||
raise ValueError("Creating cached thin and VDO volumes and pools is not supported")
|
||||
diff --git a/blivet/devicelibs/lvm.py b/blivet/devicelibs/lvm.py
|
||||
index cb6f655e..724aaff4 100644
|
||||
--- a/blivet/devicelibs/lvm.py
|
||||
+++ b/blivet/devicelibs/lvm.py
|
||||
@@ -54,6 +54,11 @@ LVM_THINP_MIN_CHUNK_SIZE = Size("64 KiB")
|
||||
LVM_THINP_MAX_CHUNK_SIZE = Size("1 GiB")
|
||||
LVM_THINP_ADDRESSABLE_CHUNK_SIZE = Size("17455015526400 B") # 15.88 TiB
|
||||
|
||||
+# cache constants
|
||||
+LVM_CACHE_MIN_METADATA_SIZE = Size("8 MiB")
|
||||
+LVM_CACHE_MAX_METADATA_SIZE = Size("16 GiB")
|
||||
+LVM_CACHE_DEFAULT_MODE = blockdev.LVMCacheMode.WRITETHROUGH
|
||||
+
|
||||
raid_levels = raid.RAIDLevels(["linear", "striped", "raid1", "raid4", "raid5", "raid6", "raid10"])
|
||||
raid_seg_types = list(itertools.chain.from_iterable([level.names for level in raid_levels if level.name != "linear"]))
|
||||
|
||||
@@ -236,3 +241,7 @@ def recommend_thpool_chunk_size(thpool_size):
|
||||
# for every ~15.88 TiB of thinpool data size
|
||||
return min(math.ceil(thpool_size / LVM_THINP_ADDRESSABLE_CHUNK_SIZE) * LVM_THINP_MIN_CHUNK_SIZE,
|
||||
LVM_THINP_MAX_CHUNK_SIZE)
|
||||
+
|
||||
+
|
||||
+def is_valid_cache_md_size(md_size):
|
||||
+ return md_size >= LVM_CACHE_MIN_METADATA_SIZE and md_size <= LVM_CACHE_MAX_METADATA_SIZE
|
||||
diff --git a/blivet/devices/lvm.py b/blivet/devices/lvm.py
|
||||
index 4700d141..7d374c3b 100644
|
||||
--- a/blivet/devices/lvm.py
|
||||
+++ b/blivet/devices/lvm.py
|
||||
@@ -43,6 +43,7 @@ from .. import util
|
||||
from ..storage_log import log_method_call
|
||||
from .. import udev
|
||||
from ..size import Size, KiB, MiB, ROUND_UP, ROUND_DOWN
|
||||
+from ..static_data.lvm_info import lvs_info
|
||||
from ..tasks import availability
|
||||
|
||||
import logging
|
||||
@@ -646,7 +647,7 @@ class LVMLogicalVolumeBase(DMDevice, RaidDevice):
|
||||
percent=None, cache_request=None, pvs=None, from_lvs=None):
|
||||
|
||||
if not exists:
|
||||
- if seg_type not in [None, "linear", "thin", "thin-pool", "cache", "vdo-pool", "vdo"] + lvm.raid_seg_types:
|
||||
+ if seg_type not in [None, "linear", "thin", "thin-pool", "cache", "vdo-pool", "vdo", "cache-pool"] + lvm.raid_seg_types:
|
||||
raise ValueError("Invalid or unsupported segment type: %s" % seg_type)
|
||||
if seg_type and seg_type in lvm.raid_seg_types and not pvs:
|
||||
raise ValueError("List of PVs has to be given for every non-linear LV")
|
||||
@@ -690,8 +691,8 @@ class LVMLogicalVolumeBase(DMDevice, RaidDevice):
|
||||
# we reserve space for it
|
||||
self._metadata_size = self.vg.pe_size
|
||||
self._size -= self._metadata_size
|
||||
- elif self.seg_type == "thin-pool":
|
||||
- # LVMThinPoolMixin sets self._metadata_size on its own
|
||||
+ elif self.seg_type in ("thin-pool", "cache_pool"):
|
||||
+ # LVMThinPoolMixin and LVMCachePoolMixin set self._metadata_size on their own
|
||||
if not self.exists and not from_lvs and not grow:
|
||||
# a thin pool we are not going to grow -> lets calculate metadata
|
||||
# size now if not given explicitly
|
||||
@@ -1619,7 +1620,6 @@ class LVMThinPoolMixin(object):
|
||||
""" A list of this pool's LVs """
|
||||
return self._lvs[:] # we don't want folks changing our list
|
||||
|
||||
- @util.requires_property("is_thin_pool")
|
||||
def autoset_md_size(self, enforced=False):
|
||||
""" If self._metadata_size not set already, it calculates the recommended value
|
||||
and sets it while subtracting the size from self.size.
|
||||
@@ -2032,9 +2032,142 @@ class LVMVDOLogicalVolumeMixin(object):
|
||||
self.pool._add_log_vol(self)
|
||||
|
||||
|
||||
+class LVMCachePoolMixin(object):
|
||||
+ def __init__(self, metadata_size, cache_mode=None):
|
||||
+ self._metadata_size = metadata_size or Size(0)
|
||||
+ self._cache_mode = cache_mode
|
||||
+
|
||||
+ def _init_check(self):
|
||||
+ if not self.is_cache_pool:
|
||||
+ return
|
||||
+
|
||||
+ if self._metadata_size and not lvm.is_valid_cache_md_size(self._metadata_size):
|
||||
+ raise ValueError("invalid metadatasize value")
|
||||
+
|
||||
+ if not self.exists and not self._pv_specs:
|
||||
+ raise ValueError("at least one fast PV must be specified to create a cache pool")
|
||||
+
|
||||
+ def _check_from_lvs(self):
|
||||
+ if self._from_lvs:
|
||||
+ if len(self._from_lvs) != 2:
|
||||
+ raise errors.DeviceError("two LVs required to create a cache pool")
|
||||
+
|
||||
+ def _convert_from_lvs(self):
|
||||
+ data_lv, metadata_lv = self._from_lvs
|
||||
+
|
||||
+ data_lv.parent_lv = self # also adds the LV to self._internal_lvs
|
||||
+ data_lv.int_lv_type = LVMInternalLVtype.data
|
||||
+ metadata_lv.parent_lv = self
|
||||
+ metadata_lv.int_lv_type = LVMInternalLVtype.meta
|
||||
+
|
||||
+ self.size = data_lv.size
|
||||
+
|
||||
+ @property
|
||||
+ def is_cache_pool(self):
|
||||
+ return self.seg_type == "cache-pool"
|
||||
+
|
||||
+ @property
|
||||
+ def profile(self):
|
||||
+ return self._profile
|
||||
+
|
||||
+ @property
|
||||
+ def type(self):
|
||||
+ return "lvmcachepool"
|
||||
+
|
||||
+ @property
|
||||
+ def resizable(self):
|
||||
+ return False
|
||||
+
|
||||
+ def read_current_size(self):
|
||||
+ log_method_call(self, exists=self.exists, path=self.path,
|
||||
+ sysfs_path=self.sysfs_path)
|
||||
+ if self.size != Size(0):
|
||||
+ return self.size
|
||||
+
|
||||
+ if self.exists:
|
||||
+ # cache pools are not active and don't have th device mapper mapping
|
||||
+ # so we can't get this from sysfs
|
||||
+ lv_info = lvs_info.cache.get(self.name)
|
||||
+ if lv_info is None:
|
||||
+ log.error("Failed to get size for existing cache pool '%s'", self.name)
|
||||
+ return Size(0)
|
||||
+ else:
|
||||
+ return Size(lv_info.size)
|
||||
+
|
||||
+ return Size(0)
|
||||
+
|
||||
+ def autoset_md_size(self, enforced=False):
|
||||
+ """ If self._metadata_size not set already, it calculates the recommended value
|
||||
+ and sets it while subtracting the size from self.size.
|
||||
+
|
||||
+ """
|
||||
+
|
||||
+ log.debug("Auto-setting cache pool metadata size")
|
||||
+
|
||||
+ if self._size <= Size(0):
|
||||
+ log.debug("Cache pool size not bigger than 0, just setting metadata size to 0")
|
||||
+ self._metadata_size = 0
|
||||
+ return
|
||||
+
|
||||
+ old_md_size = self._metadata_size
|
||||
+ if self._metadata_size == 0 or enforced:
|
||||
+ self._metadata_size = blockdev.lvm.cache_get_default_md_size(self._size)
|
||||
+ log.debug("Using recommended metadata size: %s", self._metadata_size)
|
||||
+
|
||||
+ self._metadata_size = self.vg.align(self._metadata_size, roundup=True)
|
||||
+ log.debug("Rounded metadata size to extents: %s MiB", self._metadata_size.convert_to("MiB"))
|
||||
+
|
||||
+ if self._metadata_size == old_md_size:
|
||||
+ log.debug("Rounded metadata size unchanged")
|
||||
+ else:
|
||||
+ new_size = self.size - (self._metadata_size - old_md_size)
|
||||
+ log.debug("Adjusting size from %s MiB to %s MiB",
|
||||
+ self.size.convert_to("MiB"), new_size.convert_to("MiB"))
|
||||
+ self.size = new_size
|
||||
+
|
||||
+ def _pre_create(self):
|
||||
+ # make sure all the LVs this LV should be created from exist (if any)
|
||||
+ if self._from_lvs and any(not lv.exists for lv in self._from_lvs):
|
||||
+ raise errors.DeviceError("Component LVs need to be created first")
|
||||
+
|
||||
+ def _create(self):
|
||||
+ """ Create the device. """
|
||||
+ log_method_call(self, self.name, status=self.status)
|
||||
+ if self._cache_mode:
|
||||
+ try:
|
||||
+ cache_mode = blockdev.lvm.cache_get_mode_from_str(self._cache_mode)
|
||||
+ except blockdev.LVMError as e:
|
||||
+ raise errors.DeviceError from e
|
||||
+ else:
|
||||
+ cache_mode = lvm.LVM_CACHE_DEFAULT_MODE
|
||||
+
|
||||
+ if self._from_lvs:
|
||||
+ extra = dict()
|
||||
+ if self.mode:
|
||||
+ # we need the string here, it will be passed directly to he lvm command
|
||||
+ extra["cachemode"] = self._cache_mode
|
||||
+ data_lv = six.next(lv for lv in self._internal_lvs if lv.int_lv_type == LVMInternalLVtype.data)
|
||||
+ meta_lv = six.next(lv for lv in self._internal_lvs if lv.int_lv_type == LVMInternalLVtype.meta)
|
||||
+ blockdev.lvm.cache_pool_convert(self.vg.name, data_lv.lvname, meta_lv.lvname, self.lvname, **extra)
|
||||
+ else:
|
||||
+ blockdev.lvm.cache_create_pool(self.vg.name, self.lvname, self.size,
|
||||
+ self.metadata_size,
|
||||
+ cache_mode,
|
||||
+ 0,
|
||||
+ [spec.pv.path for spec in self._pv_specs])
|
||||
+
|
||||
+ def dracut_setup_args(self):
|
||||
+ return set()
|
||||
+
|
||||
+ @property
|
||||
+ def direct(self):
|
||||
+ """ Is this device directly accessible? """
|
||||
+ return False
|
||||
+
|
||||
+
|
||||
class LVMLogicalVolumeDevice(LVMLogicalVolumeBase, LVMInternalLogicalVolumeMixin, LVMSnapshotMixin,
|
||||
LVMThinPoolMixin, LVMThinLogicalVolumeMixin, LVMVDOPoolMixin,
|
||||
- LVMVDOLogicalVolumeMixin):
|
||||
+ LVMVDOLogicalVolumeMixin, LVMCachePoolMixin):
|
||||
""" An LVM Logical Volume """
|
||||
|
||||
# generally resizable, see :property:`resizable` for details
|
||||
@@ -2046,7 +2179,7 @@ class LVMLogicalVolumeDevice(LVMLogicalVolumeBase, LVMInternalLogicalVolumeMixin
|
||||
parent_lv=None, int_type=None, origin=None, vorigin=False,
|
||||
metadata_size=None, chunk_size=None, profile=None, from_lvs=None,
|
||||
compression=False, deduplication=False, index_memory=0,
|
||||
- write_policy=None):
|
||||
+ write_policy=None, cache_mode=None):
|
||||
"""
|
||||
:param name: the device name (generally a device node's basename)
|
||||
:type name: str
|
||||
@@ -2116,6 +2249,13 @@ class LVMLogicalVolumeDevice(LVMLogicalVolumeBase, LVMInternalLogicalVolumeMixin
|
||||
:keyword write_policy: write policy for the volume or None for default
|
||||
:type write_policy: str
|
||||
|
||||
+ For cache pools only:
|
||||
+
|
||||
+ :keyword metadata_size: the size of the metadata LV
|
||||
+ :type metadata_size: :class:`~.size.Size`
|
||||
+ :keyword cache_mode: mode for the cache or None for default (writethrough)
|
||||
+ :type cache_mode: str
|
||||
+
|
||||
"""
|
||||
|
||||
if isinstance(parents, (list, ParentList)):
|
||||
@@ -2133,6 +2273,7 @@ class LVMLogicalVolumeDevice(LVMLogicalVolumeBase, LVMInternalLogicalVolumeMixin
|
||||
LVMSnapshotMixin.__init__(self, origin, vorigin)
|
||||
LVMThinPoolMixin.__init__(self, metadata_size, chunk_size, profile)
|
||||
LVMThinLogicalVolumeMixin.__init__(self)
|
||||
+ LVMCachePoolMixin.__init__(self, metadata_size, cache_mode)
|
||||
LVMLogicalVolumeBase.__init__(self, name, parents, size, uuid, seg_type,
|
||||
fmt, exists, sysfs_path, grow, maxsize,
|
||||
percent, cache_request, pvs, from_lvs)
|
||||
@@ -2144,6 +2285,7 @@ class LVMLogicalVolumeDevice(LVMLogicalVolumeBase, LVMInternalLogicalVolumeMixin
|
||||
LVMSnapshotMixin._init_check(self)
|
||||
LVMThinPoolMixin._init_check(self)
|
||||
LVMThinLogicalVolumeMixin._init_check(self)
|
||||
+ LVMCachePoolMixin._init_check(self)
|
||||
|
||||
if self._from_lvs:
|
||||
self._check_from_lvs()
|
||||
@@ -2169,6 +2311,8 @@ class LVMLogicalVolumeDevice(LVMLogicalVolumeBase, LVMInternalLogicalVolumeMixin
|
||||
ret.append(LVMVDOPoolMixin)
|
||||
if self.is_vdo_lv:
|
||||
ret.append(LVMVDOLogicalVolumeMixin)
|
||||
+ if self.is_cache_pool:
|
||||
+ ret.append(LVMCachePoolMixin)
|
||||
return ret
|
||||
|
||||
def _try_specific_call(self, name, *args, **kwargs):
|
||||
@@ -2552,6 +2696,10 @@ class LVMLogicalVolumeDevice(LVMLogicalVolumeBase, LVMInternalLogicalVolumeMixin
|
||||
|
||||
return True
|
||||
|
||||
+ @type_specific
|
||||
+ def autoset_md_size(self, enforced=False):
|
||||
+ pass
|
||||
+
|
||||
def attach_cache(self, cache_pool_lv):
|
||||
if self.is_thin_lv or self.is_snapshot_lv or self.is_internal_lv:
|
||||
raise errors.DeviceError("Cannot attach a cache pool to the '%s' LV" % self.name)
|
||||
diff --git a/tests/devices_test/lvm_test.py b/tests/devices_test/lvm_test.py
|
||||
index c349f003..a1ddaf2d 100644
|
||||
--- a/tests/devices_test/lvm_test.py
|
||||
+++ b/tests/devices_test/lvm_test.py
|
||||
@@ -867,3 +867,29 @@ class BlivetLVMVDODependenciesTest(unittest.TestCase):
|
||||
|
||||
vdo_supported = devicefactory.is_supported_device_type(devicefactory.DEVICE_TYPE_LVM_VDO)
|
||||
self.assertFalse(vdo_supported)
|
||||
+
|
||||
+
|
||||
+@unittest.skipUnless(not any(x.unavailable_type_dependencies() for x in DEVICE_CLASSES), "some unsupported device classes required for this test")
|
||||
+class BlivetNewLVMCachePoolDeviceTest(unittest.TestCase):
|
||||
+
|
||||
+ def test_new_cache_pool(self):
|
||||
+ b = blivet.Blivet()
|
||||
+ pv = StorageDevice("pv1", fmt=blivet.formats.get_format("lvmpv"),
|
||||
+ size=Size("10 GiB"), exists=True)
|
||||
+ vg = LVMVolumeGroupDevice("testvg", parents=[pv], exists=True)
|
||||
+
|
||||
+ for dev in (pv, vg):
|
||||
+ b.devicetree._add_device(dev)
|
||||
+
|
||||
+ # check that all the above devices are in the expected places
|
||||
+ self.assertEqual(set(b.devices), {pv, vg})
|
||||
+ self.assertEqual(set(b.vgs), {vg})
|
||||
+
|
||||
+ self.assertEqual(vg.size, Size("10236 MiB"))
|
||||
+
|
||||
+ cachepool = b.new_lv(name="cachepool", cache_pool=True,
|
||||
+ parents=[vg], pvs=[pv])
|
||||
+
|
||||
+ b.create_device(cachepool)
|
||||
+
|
||||
+ self.assertEqual(cachepool.type, "lvmcachepool")
|
||||
--
|
||||
2.35.3
|
||||
|
||||
|
||||
From d25d52e146559d226369afdb4b102e516bd9e332 Mon Sep 17 00:00:00 2001
|
||||
From: Vojtech Trefny <vtrefny@redhat.com>
|
||||
Date: Thu, 30 Dec 2021 16:09:04 +0100
|
||||
Subject: [PATCH 2/4] examples: Add LVM cache pool example
|
||||
|
||||
Related: rhbz#2055198
|
||||
---
|
||||
examples/lvm_cachepool.py | 59 +++++++++++++++++++++++++++++++++++++++
|
||||
1 file changed, 59 insertions(+)
|
||||
create mode 100644 examples/lvm_cachepool.py
|
||||
|
||||
diff --git a/examples/lvm_cachepool.py b/examples/lvm_cachepool.py
|
||||
new file mode 100644
|
||||
index 00000000..ab2e8a72
|
||||
--- /dev/null
|
||||
+++ b/examples/lvm_cachepool.py
|
||||
@@ -0,0 +1,59 @@
|
||||
+import os
|
||||
+
|
||||
+import blivet
|
||||
+from blivet.size import Size
|
||||
+from blivet.util import set_up_logging, create_sparse_tempfile
|
||||
+
|
||||
+
|
||||
+set_up_logging()
|
||||
+b = blivet.Blivet() # create an instance of Blivet (don't add system devices)
|
||||
+
|
||||
+# create a disk image file on which to create new devices
|
||||
+disk1_file = create_sparse_tempfile("disk1", Size("100GiB"))
|
||||
+b.disk_images["disk1"] = disk1_file
|
||||
+disk2_file = create_sparse_tempfile("disk2", Size("100GiB"))
|
||||
+b.disk_images["disk2"] = disk2_file
|
||||
+
|
||||
+b.reset()
|
||||
+
|
||||
+try:
|
||||
+ disk1 = b.devicetree.get_device_by_name("disk1")
|
||||
+ disk2 = b.devicetree.get_device_by_name("disk2")
|
||||
+
|
||||
+ b.initialize_disk(disk1)
|
||||
+ b.initialize_disk(disk2)
|
||||
+
|
||||
+ pv = b.new_partition(size=Size("50GiB"), fmt_type="lvmpv", parents=[disk1])
|
||||
+ b.create_device(pv)
|
||||
+ pv2 = b.new_partition(size=Size("50GiB"), fmt_type="lvmpv", parents=[disk2])
|
||||
+ b.create_device(pv2)
|
||||
+
|
||||
+ # allocate the partitions (decide where and on which disks they'll reside)
|
||||
+ blivet.partitioning.do_partitioning(b)
|
||||
+
|
||||
+ vg = b.new_vg(parents=[pv, pv2])
|
||||
+ b.create_device(vg)
|
||||
+
|
||||
+ # new lv with base size 5GiB and growth up to 15GiB and an ext4 filesystem
|
||||
+ lv = b.new_lv(fmt_type="ext4", size=Size("5GiB"), parents=[vg], name="cached")
|
||||
+ b.create_device(lv)
|
||||
+
|
||||
+ # new cache pool
|
||||
+ cpool = b.new_lv(size=Size("1 GiB"), parents=[vg], pvs=[pv2], cache_pool=True, name="fastlv")
|
||||
+ b.create_device(cpool)
|
||||
+
|
||||
+ # write the new partitions to disk and format them as specified
|
||||
+ b.do_it()
|
||||
+ print(b.devicetree)
|
||||
+
|
||||
+ # attach the newly created cache pool to the "slow" LV
|
||||
+ lv.attach_cache(cpool)
|
||||
+
|
||||
+ b.reset()
|
||||
+ print(b.devicetree)
|
||||
+
|
||||
+ input("Check the state and hit ENTER to trigger cleanup")
|
||||
+finally:
|
||||
+ b.devicetree.teardown_disk_images()
|
||||
+ os.unlink(disk1_file)
|
||||
+ os.unlink(disk2_file)
|
||||
--
|
||||
2.35.3
|
||||
|
||||
|
||||
From 2411d8aa082f6baf46f25d5f97455da983c0ee5f Mon Sep 17 00:00:00 2001
|
||||
From: Vojtech Trefny <vtrefny@redhat.com>
|
||||
Date: Thu, 30 Dec 2021 16:13:33 +0100
|
||||
Subject: [PATCH 3/4] lvm: Use blivet static data when checking if the VG is
|
||||
active
|
||||
|
||||
Instead of calling 'lvs' again in LVMVolumeGroupDevice.status
|
||||
|
||||
Related: rhbz#2055198
|
||||
---
|
||||
blivet/devices/lvm.py | 9 ++-------
|
||||
1 file changed, 2 insertions(+), 7 deletions(-)
|
||||
|
||||
diff --git a/blivet/devices/lvm.py b/blivet/devices/lvm.py
|
||||
index 7d374c3b..9f875e4e 100644
|
||||
--- a/blivet/devices/lvm.py
|
||||
+++ b/blivet/devices/lvm.py
|
||||
@@ -220,13 +220,8 @@ class LVMVolumeGroupDevice(ContainerDevice):
|
||||
|
||||
# special handling for incomplete VGs
|
||||
if not self.complete:
|
||||
- try:
|
||||
- lvs_info = blockdev.lvm.lvs(vg_name=self.name)
|
||||
- except blockdev.LVMError:
|
||||
- lvs_info = []
|
||||
-
|
||||
- for lv_info in lvs_info:
|
||||
- if lv_info.attr and lv_info.attr[4] == 'a':
|
||||
+ for lv_info in lvs_info.cache.values():
|
||||
+ if lv_info.vg_name == self.name and lv_info.attr and lv_info.attr[4] == 'a':
|
||||
return True
|
||||
|
||||
return False
|
||||
--
|
||||
2.35.3
|
||||
|
||||
|
||||
From c8fda78915f31f3d5011ada3c7463f85e181983b Mon Sep 17 00:00:00 2001
|
||||
From: Vojtech Trefny <vtrefny@redhat.com>
|
||||
Date: Mon, 30 May 2022 17:02:43 +0200
|
||||
Subject: [PATCH 4/4] Add option to attach a newly created cache pool to
|
||||
existing LV
|
||||
|
||||
Because we do not have action for attaching the cache pool, we
|
||||
cannot schedule both adding the fast PV to the VG and attaching
|
||||
the cache pool to existing LV. This hack allows to schedule the
|
||||
attach to happen after the cache pool is created.
|
||||
|
||||
Related: rhbz#2055198
|
||||
---
|
||||
blivet/devices/lvm.py | 38 +++++++++++++++++++++++++++++++++++---
|
||||
1 file changed, 35 insertions(+), 3 deletions(-)
|
||||
|
||||
diff --git a/blivet/devices/lvm.py b/blivet/devices/lvm.py
|
||||
index 9f875e4e..7e4fcf53 100644
|
||||
--- a/blivet/devices/lvm.py
|
||||
+++ b/blivet/devices/lvm.py
|
||||
@@ -2028,9 +2028,10 @@ class LVMVDOLogicalVolumeMixin(object):
|
||||
|
||||
|
||||
class LVMCachePoolMixin(object):
|
||||
- def __init__(self, metadata_size, cache_mode=None):
|
||||
+ def __init__(self, metadata_size, cache_mode=None, attach_to=None):
|
||||
self._metadata_size = metadata_size or Size(0)
|
||||
self._cache_mode = cache_mode
|
||||
+ self._attach_to = attach_to
|
||||
|
||||
def _init_check(self):
|
||||
if not self.is_cache_pool:
|
||||
@@ -2042,6 +2043,9 @@ class LVMCachePoolMixin(object):
|
||||
if not self.exists and not self._pv_specs:
|
||||
raise ValueError("at least one fast PV must be specified to create a cache pool")
|
||||
|
||||
+ if self._attach_to and not self._attach_to.exists:
|
||||
+ raise ValueError("cache pool can be attached only to an existing LV")
|
||||
+
|
||||
def _check_from_lvs(self):
|
||||
if self._from_lvs:
|
||||
if len(self._from_lvs) != 2:
|
||||
@@ -2150,6 +2154,31 @@ class LVMCachePoolMixin(object):
|
||||
cache_mode,
|
||||
0,
|
||||
[spec.pv.path for spec in self._pv_specs])
|
||||
+ if self._attach_to:
|
||||
+ self._attach_to.attach_cache(self)
|
||||
+
|
||||
+ def _post_create(self):
|
||||
+ if self._attach_to:
|
||||
+ # post_create tries to activate the LV and after attaching it no longer exists
|
||||
+ return
|
||||
+
|
||||
+ # pylint: disable=bad-super-call
|
||||
+ super(LVMLogicalVolumeBase, self)._post_create()
|
||||
+
|
||||
+ def add_hook(self, new=True):
|
||||
+ if self._attach_to:
|
||||
+ self._attach_to._cache = LVMCache(self._attach_to, size=self.size, exists=False,
|
||||
+ pvs=self._pv_specs, mode=self._cache_mode)
|
||||
+
|
||||
+ # pylint: disable=bad-super-call
|
||||
+ super(LVMLogicalVolumeBase, self).add_hook(new=new)
|
||||
+
|
||||
+ def remove_hook(self, modparent=True):
|
||||
+ if self._attach_to:
|
||||
+ self._attach_to._cache = None
|
||||
+
|
||||
+ # pylint: disable=bad-super-call
|
||||
+ super(LVMLogicalVolumeBase, self).remove_hook(modparent=modparent)
|
||||
|
||||
def dracut_setup_args(self):
|
||||
return set()
|
||||
@@ -2174,7 +2203,7 @@ class LVMLogicalVolumeDevice(LVMLogicalVolumeBase, LVMInternalLogicalVolumeMixin
|
||||
parent_lv=None, int_type=None, origin=None, vorigin=False,
|
||||
metadata_size=None, chunk_size=None, profile=None, from_lvs=None,
|
||||
compression=False, deduplication=False, index_memory=0,
|
||||
- write_policy=None, cache_mode=None):
|
||||
+ write_policy=None, cache_mode=None, attach_to=None):
|
||||
"""
|
||||
:param name: the device name (generally a device node's basename)
|
||||
:type name: str
|
||||
@@ -2250,6 +2279,9 @@ class LVMLogicalVolumeDevice(LVMLogicalVolumeBase, LVMInternalLogicalVolumeMixin
|
||||
:type metadata_size: :class:`~.size.Size`
|
||||
:keyword cache_mode: mode for the cache or None for default (writethrough)
|
||||
:type cache_mode: str
|
||||
+ :keyword attach_to: for non-existing cache pools a logical volume the pool should
|
||||
+ be attached to when created
|
||||
+ :type attach_to: :class:`LVMLogicalVolumeDevice`
|
||||
|
||||
"""
|
||||
|
||||
@@ -2268,7 +2300,7 @@ class LVMLogicalVolumeDevice(LVMLogicalVolumeBase, LVMInternalLogicalVolumeMixin
|
||||
LVMSnapshotMixin.__init__(self, origin, vorigin)
|
||||
LVMThinPoolMixin.__init__(self, metadata_size, chunk_size, profile)
|
||||
LVMThinLogicalVolumeMixin.__init__(self)
|
||||
- LVMCachePoolMixin.__init__(self, metadata_size, cache_mode)
|
||||
+ LVMCachePoolMixin.__init__(self, metadata_size, cache_mode, attach_to)
|
||||
LVMLogicalVolumeBase.__init__(self, name, parents, size, uuid, seg_type,
|
||||
fmt, exists, sysfs_path, grow, maxsize,
|
||||
percent, cache_request, pvs, from_lvs)
|
||||
--
|
||||
2.35.3
|
||||
|
23
SOURCES/0019-Fix-util.virt_detect-on-Xen.patch
Normal file
23
SOURCES/0019-Fix-util.virt_detect-on-Xen.patch
Normal file
@ -0,0 +1,23 @@
|
||||
From d609cebba48744c97ac7e0461f8827ab63198026 Mon Sep 17 00:00:00 2001
|
||||
From: Vojtech Trefny <vtrefny@redhat.com>
|
||||
Date: Thu, 10 Jun 2021 16:58:42 +0200
|
||||
Subject: [PATCH] Fix util.virt_detect on Xen
|
||||
|
||||
Xen is apparently still alive so we should return True for it too.
|
||||
---
|
||||
blivet/util.py | 2 +-
|
||||
1 file changed, 1 insertion(+), 1 deletion(-)
|
||||
|
||||
diff --git a/blivet/util.py b/blivet/util.py
|
||||
index 3bebb003..af60210b 100644
|
||||
--- a/blivet/util.py
|
||||
+++ b/blivet/util.py
|
||||
@@ -1130,4 +1130,4 @@ def detect_virt():
|
||||
except (safe_dbus.DBusCallError, safe_dbus.DBusPropertyError):
|
||||
return False
|
||||
else:
|
||||
- return vm[0] in ('qemu', 'kvm')
|
||||
+ return vm[0] in ('qemu', 'kvm', 'xen')
|
||||
--
|
||||
2.31.1
|
||||
|
776
SOURCES/0020-Add-support-for-NPIV-enabled-zFCP-devices.patch
Normal file
776
SOURCES/0020-Add-support-for-NPIV-enabled-zFCP-devices.patch
Normal file
@ -0,0 +1,776 @@
|
||||
From a03be3924318788e42bcdb3ed6a5334aed771c43 Mon Sep 17 00:00:00 2001
|
||||
From: Jan Stodola <jstodola@redhat.com>
|
||||
Date: Thu, 28 Oct 2021 21:17:25 +0200
|
||||
Subject: [PATCH 1/8] Fix removing zFCP SCSI devices
|
||||
|
||||
Values parsed from /proc/scsi/scsi were not correctly used to assemble
|
||||
paths to SCSI devices.
|
||||
|
||||
For example:
|
||||
/sys/bus/scsi/devices/0:0:00:00/
|
||||
was incorrectly accessed instead of:
|
||||
/sys/bus/scsi/devices/0:0:0:0/
|
||||
|
||||
Switch to a more reliable way of listing the available SCSI devices.
|
||||
---
|
||||
blivet/zfcp.py | 17 ++++-------------
|
||||
1 file changed, 4 insertions(+), 13 deletions(-)
|
||||
|
||||
diff --git a/blivet/zfcp.py b/blivet/zfcp.py
|
||||
index 93af5419..3747290e 100644
|
||||
--- a/blivet/zfcp.py
|
||||
+++ b/blivet/zfcp.py
|
||||
@@ -20,6 +20,7 @@
|
||||
#
|
||||
|
||||
import os
|
||||
+import re
|
||||
from . import udev
|
||||
from . import util
|
||||
from .i18n import _
|
||||
@@ -167,20 +168,10 @@ class ZFCPDevice:
|
||||
return True
|
||||
|
||||
def offline_scsi_device(self):
|
||||
- f = open("/proc/scsi/scsi", "r")
|
||||
- lines = f.readlines()
|
||||
- f.close()
|
||||
- # alternatively iterate over /sys/bus/scsi/devices/*:0:*:*/
|
||||
+ # A list of existing SCSI devices in format Host:Bus:Target:Lun
|
||||
+ scsi_devices = [f for f in os.listdir(scsidevsysfs) if re.search(r'^[0-9]+:[0-9]+:[0-9]+:[0-9]+$', f)]
|
||||
|
||||
- for line in lines:
|
||||
- if not line.startswith("Host"):
|
||||
- continue
|
||||
- scsihost = line.split()
|
||||
- host = scsihost[1]
|
||||
- channel = "0"
|
||||
- devid = scsihost[5]
|
||||
- lun = scsihost[7]
|
||||
- scsidev = "%s:%s:%s:%s" % (host[4:], channel, devid, lun)
|
||||
+ for scsidev in scsi_devices:
|
||||
fcpsysfs = "%s/%s" % (scsidevsysfs, scsidev)
|
||||
scsidel = "%s/%s/delete" % (scsidevsysfs, scsidev)
|
||||
|
||||
--
|
||||
2.36.1
|
||||
|
||||
|
||||
From 82bd018fdc47c64f30d8422eb90bc76564072a26 Mon Sep 17 00:00:00 2001
|
||||
From: Jan Stodola <jstodola@redhat.com>
|
||||
Date: Sun, 21 Nov 2021 02:47:45 +0100
|
||||
Subject: [PATCH 2/8] Refactor the ZFCPDevice class
|
||||
|
||||
Add a new base class for zFCP devices.
|
||||
Move code to the new base class.
|
||||
Improve documentation.
|
||||
---
|
||||
blivet/zfcp.py | 131 +++++++++++++++++++++++++++++++++++--------------
|
||||
1 file changed, 95 insertions(+), 36 deletions(-)
|
||||
|
||||
diff --git a/blivet/zfcp.py b/blivet/zfcp.py
|
||||
index 3747290e..4a50f65f 100644
|
||||
--- a/blivet/zfcp.py
|
||||
+++ b/blivet/zfcp.py
|
||||
@@ -21,6 +21,7 @@
|
||||
|
||||
import os
|
||||
import re
|
||||
+from abc import ABC
|
||||
from . import udev
|
||||
from . import util
|
||||
from .i18n import _
|
||||
@@ -46,29 +47,19 @@ zfcpsysfs = "/sys/bus/ccw/drivers/zfcp"
|
||||
scsidevsysfs = "/sys/bus/scsi/devices"
|
||||
zfcpconf = "/etc/zfcp.conf"
|
||||
|
||||
+class ZFCPDeviceBase(ABC):
|
||||
+ """An abstract base class for zFCP storage devices."""
|
||||
|
||||
-class ZFCPDevice:
|
||||
- """
|
||||
- .. warning::
|
||||
- Since this is a singleton class, calling deepcopy() on the instance
|
||||
- just returns ``self`` with no copy being created.
|
||||
- """
|
||||
-
|
||||
- def __init__(self, devnum, wwpn, fcplun):
|
||||
+ def __init__(self, devnum):
|
||||
self.devnum = blockdev.s390.sanitize_dev_input(devnum)
|
||||
- self.wwpn = blockdev.s390.zfcp_sanitize_wwpn_input(wwpn)
|
||||
- self.fcplun = blockdev.s390.zfcp_sanitize_lun_input(fcplun)
|
||||
-
|
||||
if not self.devnum:
|
||||
raise ValueError(_("You have not specified a device number or the number is invalid"))
|
||||
- if not self.wwpn:
|
||||
- raise ValueError(_("You have not specified a worldwide port name or the name is invalid."))
|
||||
- if not self.fcplun:
|
||||
- raise ValueError(_("You have not specified a FCP LUN or the number is invalid."))
|
||||
+
|
||||
+ self._device_online_path = os.path.join(zfcpsysfs, self.devnum, "online")
|
||||
|
||||
# Force str and unicode types in case any of the properties are unicode
|
||||
def _to_string(self):
|
||||
- return "%s %s %s" % (self.devnum, self.wwpn, self.fcplun)
|
||||
+ return str(self.devnum)
|
||||
|
||||
def __str__(self):
|
||||
return stringize(self._to_string())
|
||||
@@ -76,33 +67,97 @@ class ZFCPDevice:
|
||||
def __unicode__(self):
|
||||
return unicodeize(self._to_string())
|
||||
|
||||
- def online_device(self):
|
||||
- online = "%s/%s/online" % (zfcpsysfs, self.devnum)
|
||||
- portadd = "%s/%s/port_add" % (zfcpsysfs, self.devnum)
|
||||
- portdir = "%s/%s/%s" % (zfcpsysfs, self.devnum, self.wwpn)
|
||||
- unitadd = "%s/unit_add" % (portdir)
|
||||
- unitdir = "%s/%s" % (portdir, self.fcplun)
|
||||
- failed = "%s/failed" % (unitdir)
|
||||
+ def _free_device(self):
|
||||
+ """Remove the device from the I/O ignore list to make it visible to the system.
|
||||
+
|
||||
+ :raises: ValueError if the device cannot be removed from the I/O ignore list
|
||||
+ """
|
||||
|
||||
- if not os.path.exists(online):
|
||||
+ if not os.path.exists(self._device_online_path):
|
||||
log.info("Freeing zFCP device %s", self.devnum)
|
||||
util.run_program(["zfcp_cio_free", "-d", self.devnum])
|
||||
|
||||
- if not os.path.exists(online):
|
||||
+ if not os.path.exists(self._device_online_path):
|
||||
raise ValueError(_("zFCP device %s not found, not even in device ignore list.") %
|
||||
(self.devnum,))
|
||||
|
||||
+ def _set_zfcp_device_online(self):
|
||||
+ """Set the zFCP device online.
|
||||
+
|
||||
+ :raises: ValueError if the device cannot be set online
|
||||
+ """
|
||||
+
|
||||
try:
|
||||
- f = open(online, "r")
|
||||
- devonline = f.readline().strip()
|
||||
- f.close()
|
||||
+ with open(self._device_online_path) as f:
|
||||
+ devonline = f.readline().strip()
|
||||
if devonline != "1":
|
||||
- logged_write_line_to_file(online, "1")
|
||||
+ logged_write_line_to_file(self._device_online_path, "1")
|
||||
except OSError as e:
|
||||
raise ValueError(_("Could not set zFCP device %(devnum)s "
|
||||
"online (%(e)s).")
|
||||
% {'devnum': self.devnum, 'e': e})
|
||||
|
||||
+ def _set_zfcp_device_offline(self):
|
||||
+ """Set the zFCP device offline.
|
||||
+
|
||||
+ :raises: ValueError if the device cannot be set offline
|
||||
+ """
|
||||
+
|
||||
+ try:
|
||||
+ logged_write_line_to_file(self._device_online_path, "0")
|
||||
+ except OSError as e:
|
||||
+ raise ValueError(_("Could not set zFCP device %(devnum)s "
|
||||
+ "offline (%(e)s).")
|
||||
+ % {'devnum': self.devnum, 'e': e})
|
||||
+
|
||||
+ def online_device(self):
|
||||
+ """Initialize the device and make its storage block device(s) ready to use.
|
||||
+
|
||||
+ :returns: True if success
|
||||
+ :raises: ValueError if the device cannot be initialized
|
||||
+ """
|
||||
+
|
||||
+ self._free_device()
|
||||
+ self._set_zfcp_device_online()
|
||||
+ return True
|
||||
+
|
||||
+
|
||||
+class ZFCPDevice(ZFCPDeviceBase):
|
||||
+ """A class for zFCP devices that are not configured in NPIV mode. Such
|
||||
+ devices have to be specified by a device number, WWPN and LUN.
|
||||
+ """
|
||||
+
|
||||
+ def __init__(self, devnum, wwpn, fcplun):
|
||||
+ super().__init__(devnum)
|
||||
+
|
||||
+ self.wwpn = blockdev.s390.zfcp_sanitize_wwpn_input(wwpn)
|
||||
+ if not self.wwpn:
|
||||
+ raise ValueError(_("You have not specified a worldwide port name or the name is invalid."))
|
||||
+
|
||||
+ self.fcplun = blockdev.s390.zfcp_sanitize_lun_input(fcplun)
|
||||
+ if not self.fcplun:
|
||||
+ raise ValueError(_("You have not specified a FCP LUN or the number is invalid."))
|
||||
+
|
||||
+ # Force str and unicode types in case any of the properties are unicode
|
||||
+ def _to_string(self):
|
||||
+ return "{} {} {}".format(self.devnum, self.wwpn, self.fcplun)
|
||||
+
|
||||
+ def online_device(self):
|
||||
+ """Initialize the device and make its storage block device(s) ready to use.
|
||||
+
|
||||
+ :returns: True if success
|
||||
+ :raises: ValueError if the device cannot be initialized
|
||||
+ """
|
||||
+
|
||||
+ super().online_device()
|
||||
+
|
||||
+ portadd = "%s/%s/port_add" % (zfcpsysfs, self.devnum)
|
||||
+ portdir = "%s/%s/%s" % (zfcpsysfs, self.devnum, self.wwpn)
|
||||
+ unitadd = "%s/unit_add" % (portdir)
|
||||
+ unitdir = "%s/%s" % (portdir, self.fcplun)
|
||||
+ failed = "%s/failed" % (unitdir)
|
||||
+
|
||||
+ # create the sysfs directory for the WWPN/port
|
||||
if not os.path.exists(portdir):
|
||||
if os.path.exists(portadd):
|
||||
# older zfcp sysfs interface
|
||||
@@ -127,6 +182,7 @@ class ZFCPDevice:
|
||||
"there.", {'wwpn': self.wwpn,
|
||||
'devnum': self.devnum})
|
||||
|
||||
+ # create the sysfs directory for the LUN/unit
|
||||
if not os.path.exists(unitdir):
|
||||
try:
|
||||
logged_write_line_to_file(unitadd, self.fcplun)
|
||||
@@ -144,6 +200,7 @@ class ZFCPDevice:
|
||||
'wwpn': self.wwpn,
|
||||
'devnum': self.devnum})
|
||||
|
||||
+ # check the state of the LUN
|
||||
fail = "0"
|
||||
try:
|
||||
f = open(failed, "r")
|
||||
@@ -168,6 +225,8 @@ class ZFCPDevice:
|
||||
return True
|
||||
|
||||
def offline_scsi_device(self):
|
||||
+ """Find SCSI devices associated to the zFCP device and remove them from the system."""
|
||||
+
|
||||
# A list of existing SCSI devices in format Host:Bus:Target:Lun
|
||||
scsi_devices = [f for f in os.listdir(scsidevsysfs) if re.search(r'^[0-9]+:[0-9]+:[0-9]+:[0-9]+$', f)]
|
||||
|
||||
@@ -196,7 +255,8 @@ class ZFCPDevice:
|
||||
self.devnum, self.wwpn, self.fcplun)
|
||||
|
||||
def offline_device(self):
|
||||
- offline = "%s/%s/online" % (zfcpsysfs, self.devnum)
|
||||
+ """Remove the zFCP device from the system."""
|
||||
+
|
||||
portadd = "%s/%s/port_add" % (zfcpsysfs, self.devnum)
|
||||
portremove = "%s/%s/port_remove" % (zfcpsysfs, self.devnum)
|
||||
unitremove = "%s/%s/%s/unit_remove" % (zfcpsysfs, self.devnum, self.wwpn)
|
||||
@@ -212,6 +272,7 @@ class ZFCPDevice:
|
||||
% {'devnum': self.devnum, 'wwpn': self.wwpn,
|
||||
'fcplun': self.fcplun, 'e': e})
|
||||
|
||||
+ # remove the LUN
|
||||
try:
|
||||
logged_write_line_to_file(unitremove, self.fcplun)
|
||||
except OSError as e:
|
||||
@@ -221,6 +282,7 @@ class ZFCPDevice:
|
||||
% {'fcplun': self.fcplun, 'wwpn': self.wwpn,
|
||||
'devnum': self.devnum, 'e': e})
|
||||
|
||||
+ # remove the WWPN only if there are no other LUNs attached
|
||||
if os.path.exists(portadd):
|
||||
# only try to remove ports with older zfcp sysfs interface
|
||||
for lun in os.listdir(portdir):
|
||||
@@ -238,6 +300,7 @@ class ZFCPDevice:
|
||||
% {'wwpn': self.wwpn,
|
||||
'devnum': self.devnum, 'e': e})
|
||||
|
||||
+ # check if there are other WWPNs existing for the zFCP device number
|
||||
if os.path.exists(portadd):
|
||||
# older zfcp sysfs interface
|
||||
for port in os.listdir(devdir):
|
||||
@@ -256,12 +319,8 @@ class ZFCPDevice:
|
||||
self.devnum, luns[0])
|
||||
return True
|
||||
|
||||
- try:
|
||||
- logged_write_line_to_file(offline, "0")
|
||||
- except OSError as e:
|
||||
- raise ValueError(_("Could not set zFCP device %(devnum)s "
|
||||
- "offline (%(e)s).")
|
||||
- % {'devnum': self.devnum, 'e': e})
|
||||
+ # no other WWPNs/LUNs exists for this device number, it's safe to bring it offline
|
||||
+ self._set_zfcp_device_offline()
|
||||
|
||||
return True
|
||||
|
||||
--
|
||||
2.36.1
|
||||
|
||||
|
||||
From a9b9fe124dbc23104c0b60c8e0326cab3eb7a28d Mon Sep 17 00:00:00 2001
|
||||
From: Jan Stodola <jstodola@redhat.com>
|
||||
Date: Sun, 21 Nov 2021 02:35:05 +0100
|
||||
Subject: [PATCH 3/8] Move offline_scsi_device() to the base class
|
||||
|
||||
---
|
||||
blivet/zfcp.py | 74 ++++++++++++++++++++++++++++++--------------------
|
||||
1 file changed, 44 insertions(+), 30 deletions(-)
|
||||
|
||||
diff --git a/blivet/zfcp.py b/blivet/zfcp.py
|
||||
index 4a50f65f..af8f841d 100644
|
||||
--- a/blivet/zfcp.py
|
||||
+++ b/blivet/zfcp.py
|
||||
@@ -110,6 +110,15 @@ class ZFCPDeviceBase(ABC):
|
||||
"offline (%(e)s).")
|
||||
% {'devnum': self.devnum, 'e': e})
|
||||
|
||||
+ def _is_scsi_associated_with_fcp(self, fcphbasysfs, _fcpwwpnsysfs, _fcplunsysfs):
|
||||
+ """Decide if the SCSI device with the provided SCSI attributes
|
||||
+ corresponds to the zFCP device.
|
||||
+
|
||||
+ :returns: True or False
|
||||
+ """
|
||||
+
|
||||
+ return fcphbasysfs == self.devnum
|
||||
+
|
||||
def online_device(self):
|
||||
"""Initialize the device and make its storage block device(s) ready to use.
|
||||
|
||||
@@ -121,6 +130,30 @@ class ZFCPDeviceBase(ABC):
|
||||
self._set_zfcp_device_online()
|
||||
return True
|
||||
|
||||
+ def offline_scsi_device(self):
|
||||
+ """Find SCSI devices associated to the zFCP device and remove them from the system."""
|
||||
+
|
||||
+ # A list of existing SCSI devices in format Host:Bus:Target:Lun
|
||||
+ scsi_devices = [f for f in os.listdir(scsidevsysfs) if re.search(r'^[0-9]+:[0-9]+:[0-9]+:[0-9]+$', f)]
|
||||
+
|
||||
+ for scsidev in scsi_devices:
|
||||
+ fcpsysfs = os.path.join(scsidevsysfs, scsidev)
|
||||
+
|
||||
+ with open(os.path.join(fcpsysfs, "hba_id")) as f:
|
||||
+ fcphbasysfs = f.readline().strip()
|
||||
+ with open(os.path.join(fcpsysfs, "wwpn")) as f:
|
||||
+ fcpwwpnsysfs = f.readline().strip()
|
||||
+ with open(os.path.join(fcpsysfs, "fcp_lun")) as f:
|
||||
+ fcplunsysfs = f.readline().strip()
|
||||
+
|
||||
+ if self._is_scsi_associated_with_fcp(fcphbasysfs, fcpwwpnsysfs, fcplunsysfs):
|
||||
+ scsidel = os.path.join(scsidevsysfs, scsidev, "delete")
|
||||
+ logged_write_line_to_file(scsidel, "1")
|
||||
+ udev.settle()
|
||||
+ return
|
||||
+
|
||||
+ log.warning("No scsi device found to delete for zfcp %s", self)
|
||||
+
|
||||
|
||||
class ZFCPDevice(ZFCPDeviceBase):
|
||||
"""A class for zFCP devices that are not configured in NPIV mode. Such
|
||||
@@ -142,6 +175,17 @@ class ZFCPDevice(ZFCPDeviceBase):
|
||||
def _to_string(self):
|
||||
return "{} {} {}".format(self.devnum, self.wwpn, self.fcplun)
|
||||
|
||||
+ def _is_scsi_associated_with_fcp(self, fcphbasysfs, fcpwwpnsysfs, fcplunsysfs):
|
||||
+ """Decide if the SCSI device with the provided SCSI attributes
|
||||
+ corresponds to the zFCP device.
|
||||
+
|
||||
+ :returns: True or False
|
||||
+ """
|
||||
+
|
||||
+ return (fcphbasysfs == self.devnum and
|
||||
+ fcpwwpnsysfs == self.wwpn and
|
||||
+ fcplunsysfs == self.fcplun)
|
||||
+
|
||||
def online_device(self):
|
||||
"""Initialize the device and make its storage block device(s) ready to use.
|
||||
|
||||
@@ -224,36 +268,6 @@ class ZFCPDevice(ZFCPDeviceBase):
|
||||
|
||||
return True
|
||||
|
||||
- def offline_scsi_device(self):
|
||||
- """Find SCSI devices associated to the zFCP device and remove them from the system."""
|
||||
-
|
||||
- # A list of existing SCSI devices in format Host:Bus:Target:Lun
|
||||
- scsi_devices = [f for f in os.listdir(scsidevsysfs) if re.search(r'^[0-9]+:[0-9]+:[0-9]+:[0-9]+$', f)]
|
||||
-
|
||||
- for scsidev in scsi_devices:
|
||||
- fcpsysfs = "%s/%s" % (scsidevsysfs, scsidev)
|
||||
- scsidel = "%s/%s/delete" % (scsidevsysfs, scsidev)
|
||||
-
|
||||
- f = open("%s/hba_id" % (fcpsysfs), "r")
|
||||
- fcphbasysfs = f.readline().strip()
|
||||
- f.close()
|
||||
- f = open("%s/wwpn" % (fcpsysfs), "r")
|
||||
- fcpwwpnsysfs = f.readline().strip()
|
||||
- f.close()
|
||||
- f = open("%s/fcp_lun" % (fcpsysfs), "r")
|
||||
- fcplunsysfs = f.readline().strip()
|
||||
- f.close()
|
||||
-
|
||||
- if fcphbasysfs == self.devnum \
|
||||
- and fcpwwpnsysfs == self.wwpn \
|
||||
- and fcplunsysfs == self.fcplun:
|
||||
- logged_write_line_to_file(scsidel, "1")
|
||||
- udev.settle()
|
||||
- return
|
||||
-
|
||||
- log.warning("no scsi device found to delete for zfcp %s %s %s",
|
||||
- self.devnum, self.wwpn, self.fcplun)
|
||||
-
|
||||
def offline_device(self):
|
||||
"""Remove the zFCP device from the system."""
|
||||
|
||||
--
|
||||
2.36.1
|
||||
|
||||
|
||||
From 47997255cf12505d743d6e01a40a51b23ed64a6d Mon Sep 17 00:00:00 2001
|
||||
From: Jan Stodola <jstodola@redhat.com>
|
||||
Date: Sat, 6 Nov 2021 21:27:52 +0100
|
||||
Subject: [PATCH 4/8] Allow to delete more than one SCSI device
|
||||
|
||||
NPIV zFCP devices can attach more than one SCSI device, so allow to
|
||||
delete them all. For non-NPIV devices it means possible slowdown, since
|
||||
all SCSI devices would now be checked.
|
||||
---
|
||||
blivet/zfcp.py | 6 ++++--
|
||||
1 file changed, 4 insertions(+), 2 deletions(-)
|
||||
|
||||
diff --git a/blivet/zfcp.py b/blivet/zfcp.py
|
||||
index af8f841d..3b3f623b 100644
|
||||
--- a/blivet/zfcp.py
|
||||
+++ b/blivet/zfcp.py
|
||||
@@ -136,6 +136,7 @@ class ZFCPDeviceBase(ABC):
|
||||
# A list of existing SCSI devices in format Host:Bus:Target:Lun
|
||||
scsi_devices = [f for f in os.listdir(scsidevsysfs) if re.search(r'^[0-9]+:[0-9]+:[0-9]+:[0-9]+$', f)]
|
||||
|
||||
+ scsi_device_found = False
|
||||
for scsidev in scsi_devices:
|
||||
fcpsysfs = os.path.join(scsidevsysfs, scsidev)
|
||||
|
||||
@@ -147,12 +148,13 @@ class ZFCPDeviceBase(ABC):
|
||||
fcplunsysfs = f.readline().strip()
|
||||
|
||||
if self._is_scsi_associated_with_fcp(fcphbasysfs, fcpwwpnsysfs, fcplunsysfs):
|
||||
+ scsi_device_found = True
|
||||
scsidel = os.path.join(scsidevsysfs, scsidev, "delete")
|
||||
logged_write_line_to_file(scsidel, "1")
|
||||
udev.settle()
|
||||
- return
|
||||
|
||||
- log.warning("No scsi device found to delete for zfcp %s", self)
|
||||
+ if not scsi_device_found:
|
||||
+ log.warning("No scsi device found to delete for zfcp %s", self)
|
||||
|
||||
|
||||
class ZFCPDevice(ZFCPDeviceBase):
|
||||
--
|
||||
2.36.1
|
||||
|
||||
|
||||
From feace41093c97dc88aa20b07a5ff6049df4bd01d Mon Sep 17 00:00:00 2001
|
||||
From: Jan Stodola <jstodola@redhat.com>
|
||||
Date: Sun, 21 Nov 2021 03:01:02 +0100
|
||||
Subject: [PATCH 5/8] Add a function for reading the value of a kernel module
|
||||
parameter
|
||||
|
||||
---
|
||||
blivet/util.py | 33 +++++++++++++++++++++++++++++++++
|
||||
tests/util_test.py | 11 +++++++++++
|
||||
2 files changed, 44 insertions(+)
|
||||
|
||||
diff --git a/blivet/util.py b/blivet/util.py
|
||||
index af60210b..cbef65e0 100644
|
||||
--- a/blivet/util.py
|
||||
+++ b/blivet/util.py
|
||||
@@ -1131,3 +1131,36 @@ def detect_virt():
|
||||
return False
|
||||
else:
|
||||
return vm[0] in ('qemu', 'kvm', 'xen')
|
||||
+
|
||||
+
|
||||
+def natural_sort_key(device):
|
||||
+ """ Sorting key for devices which makes sure partitions are sorted in natural
|
||||
+ way, e.g. 'sda1, sda2, ..., sda10' and not like 'sda1, sda10, sda2, ...'
|
||||
+ """
|
||||
+ if device.type == "partition" and device.parted_partition and device.disk:
|
||||
+ part_num = getattr(device.parted_partition, "number", -1)
|
||||
+ return [device.disk.name, part_num]
|
||||
+ else:
|
||||
+ return [device.name, 0]
|
||||
+
|
||||
+
|
||||
+def get_kernel_module_parameter(module, parameter):
|
||||
+ """ Return the value of a given kernel module parameter
|
||||
+
|
||||
+ :param str module: a kernel module
|
||||
+ :param str parameter: a module parameter
|
||||
+ :returns: the value of the given kernel module parameter or None
|
||||
+ :rtype: str
|
||||
+ """
|
||||
+
|
||||
+ value = None
|
||||
+
|
||||
+ parameter_path = os.path.join("/sys/module", module, "parameters", parameter)
|
||||
+ try:
|
||||
+ with open(parameter_path) as f:
|
||||
+ value = f.read().strip()
|
||||
+ except IOError as e:
|
||||
+ log.warning("Couldn't get the value of the parameter '%s' from the kernel module '%s': %s",
|
||||
+ parameter, module, str(e))
|
||||
+
|
||||
+ return value
|
||||
diff --git a/tests/util_test.py b/tests/util_test.py
|
||||
index 853b6166..ed2549ad 100644
|
||||
--- a/tests/util_test.py
|
||||
+++ b/tests/util_test.py
|
||||
@@ -180,3 +180,14 @@ class GetSysfsAttrTestCase(unittest.TestCase):
|
||||
# the unicode replacement character (U+FFFD) should be used instead
|
||||
model = util.get_sysfs_attr(sysfs, "model")
|
||||
self.assertEqual(model, "test model\ufffd")
|
||||
+
|
||||
+
|
||||
+class GetKernelModuleParameterTestCase(unittest.TestCase):
|
||||
+
|
||||
+ def test_nonexisting_kernel_module(self):
|
||||
+ self.assertIsNone(util.get_kernel_module_parameter("unknown_module", "unknown_parameter"))
|
||||
+
|
||||
+ def test_get_kernel_module_parameter_value(self):
|
||||
+ with mock.patch('blivet.util.open', mock.mock_open(read_data='value\n')):
|
||||
+ value = util.get_kernel_module_parameter("module", "parameter")
|
||||
+ self.assertEqual(value, "value")
|
||||
--
|
||||
2.36.1
|
||||
|
||||
|
||||
From cea53c0f95793d8041391dd8e1edc58aa0f7868c Mon Sep 17 00:00:00 2001
|
||||
From: Jan Stodola <jstodola@redhat.com>
|
||||
Date: Sun, 21 Nov 2021 03:01:46 +0100
|
||||
Subject: [PATCH 6/8] LUN and WWPN should not be used for NPIV zFCP devices
|
||||
|
||||
Log a warning if activating a zFCP device in NPIV mode and WWPN or
|
||||
LUN have been provided. They are superfluous for NPIV devices.
|
||||
---
|
||||
blivet/zfcp.py | 58 +++++++++++++++++++++++++++++++++++++++++++++++++-
|
||||
1 file changed, 57 insertions(+), 1 deletion(-)
|
||||
|
||||
diff --git a/blivet/zfcp.py b/blivet/zfcp.py
|
||||
index 3b3f623b..726e9364 100644
|
||||
--- a/blivet/zfcp.py
|
||||
+++ b/blivet/zfcp.py
|
||||
@@ -22,6 +22,7 @@
|
||||
import os
|
||||
import re
|
||||
from abc import ABC
|
||||
+import glob
|
||||
from . import udev
|
||||
from . import util
|
||||
from .i18n import _
|
||||
@@ -47,6 +48,55 @@ zfcpsysfs = "/sys/bus/ccw/drivers/zfcp"
|
||||
scsidevsysfs = "/sys/bus/scsi/devices"
|
||||
zfcpconf = "/etc/zfcp.conf"
|
||||
|
||||
+
|
||||
+def _is_lun_scan_allowed():
|
||||
+ """Return True if automatic LUN scanning is enabled by the kernel."""
|
||||
+
|
||||
+ allow_lun_scan = util.get_kernel_module_parameter("zfcp", "allow_lun_scan")
|
||||
+ return allow_lun_scan == "Y"
|
||||
+
|
||||
+
|
||||
+def _is_port_in_npiv_mode(device_id):
|
||||
+ """Return True if the device ID is configured in NPIV mode. See
|
||||
+ https://www.ibm.com/docs/en/linux-on-systems?topic=devices-use-npiv
|
||||
+ """
|
||||
+
|
||||
+ port_in_npiv_mode = False
|
||||
+ port_type_path = "/sys/bus/ccw/devices/{}/host*/fc_host/host*/port_type".format(device_id)
|
||||
+ port_type_paths = glob.glob(port_type_path)
|
||||
+ try:
|
||||
+ for filename in port_type_paths:
|
||||
+ with open(filename) as f:
|
||||
+ port_type = f.read()
|
||||
+ if re.search(r"(^|\s)NPIV(\s|$)", port_type):
|
||||
+ port_in_npiv_mode = True
|
||||
+ except OSError as e:
|
||||
+ log.warning("Couldn't read the port_type attribute of the %s device: %s", device_id, str(e))
|
||||
+ port_in_npiv_mode = False
|
||||
+
|
||||
+ return port_in_npiv_mode
|
||||
+
|
||||
+
|
||||
+def is_npiv_enabled(device_id):
|
||||
+ """Return True if the given zFCP device ID is configured and usable in
|
||||
+ NPIV (N_Port ID Virtualization) mode.
|
||||
+
|
||||
+ :returns: True or False
|
||||
+ """
|
||||
+
|
||||
+ # LUN scanning disabled by the kernel module prevents using the device in NPIV mode
|
||||
+ if not _is_lun_scan_allowed():
|
||||
+ log.warning("Automatic LUN scanning is disabled by the zfcp kernel module.")
|
||||
+ return False
|
||||
+
|
||||
+ # The port itself has to be configured in NPIV mode
|
||||
+ if not _is_port_in_npiv_mode(device_id):
|
||||
+ log.warning("The zFCP device %s is not configured in NPIV mode.", device_id)
|
||||
+ return False
|
||||
+
|
||||
+ return True
|
||||
+
|
||||
+
|
||||
class ZFCPDeviceBase(ABC):
|
||||
"""An abstract base class for zFCP storage devices."""
|
||||
|
||||
@@ -203,6 +253,13 @@ class ZFCPDevice(ZFCPDeviceBase):
|
||||
unitdir = "%s/%s" % (portdir, self.fcplun)
|
||||
failed = "%s/failed" % (unitdir)
|
||||
|
||||
+ # Activating an NPIV enabled device using devnum, WWPN and LUN should still be possible
|
||||
+ # as this method was used as a workaround until the support for NPIV enabled devices has
|
||||
+ # been implemented. Just log a warning message and continue.
|
||||
+ if is_npiv_enabled(self.devnum):
|
||||
+ log.warning("zFCP device %s in NPIV mode brought online. All LUNs will be activated "
|
||||
+ "automatically although WWPN and LUN have been provided.", self.devnum)
|
||||
+
|
||||
# create the sysfs directory for the WWPN/port
|
||||
if not os.path.exists(portdir):
|
||||
if os.path.exists(portadd):
|
||||
@@ -327,7 +384,6 @@ class ZFCPDevice(ZFCPDeviceBase):
|
||||
return True
|
||||
else:
|
||||
# newer zfcp sysfs interface with auto port scan
|
||||
- import glob
|
||||
luns = glob.glob("%s/0x????????????????/0x????????????????"
|
||||
% (devdir,))
|
||||
if len(luns) != 0:
|
||||
--
|
||||
2.36.1
|
||||
|
||||
|
||||
From ff01832941a62fc3113983a51a22369566b3f900 Mon Sep 17 00:00:00 2001
|
||||
From: Jan Stodola <jstodola@redhat.com>
|
||||
Date: Sat, 6 Nov 2021 21:27:52 +0100
|
||||
Subject: [PATCH 7/8] Add new class for NPIV-enabled devices
|
||||
|
||||
---
|
||||
blivet/zfcp.py | 53 +++++++++++++++++++++++++++++++++++++++++++++++---
|
||||
1 file changed, 50 insertions(+), 3 deletions(-)
|
||||
|
||||
diff --git a/blivet/zfcp.py b/blivet/zfcp.py
|
||||
index 726e9364..e6c0e48a 100644
|
||||
--- a/blivet/zfcp.py
|
||||
+++ b/blivet/zfcp.py
|
||||
@@ -397,6 +397,44 @@ class ZFCPDevice(ZFCPDeviceBase):
|
||||
return True
|
||||
|
||||
|
||||
+class ZFCPNPIVDevice(ZFCPDeviceBase):
|
||||
+ """Class for zFCP devices configured in NPIV mode. Only a zFCP device number is
|
||||
+ needed for such devices.
|
||||
+ """
|
||||
+
|
||||
+ def online_device(self):
|
||||
+ """Initialize the device and make its storage block device(s) ready to use.
|
||||
+
|
||||
+ :returns: True if success
|
||||
+ :raises: ValueError if the device cannot be initialized
|
||||
+ """
|
||||
+
|
||||
+ super().online_device()
|
||||
+
|
||||
+ if not is_npiv_enabled(self.devnum):
|
||||
+ raise ValueError(_("zFCP device %s cannot be used in NPIV mode.") % self)
|
||||
+
|
||||
+ return True
|
||||
+
|
||||
+ def offline_device(self):
|
||||
+ """Remove the zFCP device from the system.
|
||||
+
|
||||
+ :returns: True if success
|
||||
+ :raises: ValueError if the device cannot be brought offline
|
||||
+ """
|
||||
+
|
||||
+ try:
|
||||
+ self.offline_scsi_device()
|
||||
+ except OSError as e:
|
||||
+ raise ValueError(_("Could not correctly delete SCSI device of "
|
||||
+ "zFCP %(zfcpdev)s (%(e)s).")
|
||||
+ % {'zfcpdev': self, 'e': e})
|
||||
+
|
||||
+ self._set_zfcp_device_offline()
|
||||
+
|
||||
+ return True
|
||||
+
|
||||
+
|
||||
class zFCP:
|
||||
|
||||
""" ZFCP utility class.
|
||||
@@ -439,7 +477,12 @@ class zFCP:
|
||||
|
||||
fields = line.split()
|
||||
|
||||
- if len(fields) == 3:
|
||||
+ # NPIV enabled device
|
||||
+ if len(fields) == 1:
|
||||
+ devnum = fields[0]
|
||||
+ wwpn = None
|
||||
+ fcplun = None
|
||||
+ elif len(fields) == 3:
|
||||
devnum = fields[0]
|
||||
wwpn = fields[1]
|
||||
fcplun = fields[2]
|
||||
@@ -458,8 +501,12 @@ class zFCP:
|
||||
except ValueError as e:
|
||||
log.warning("%s", str(e))
|
||||
|
||||
- def add_fcp(self, devnum, wwpn, fcplun):
|
||||
- d = ZFCPDevice(devnum, wwpn, fcplun)
|
||||
+ def add_fcp(self, devnum, wwpn=None, fcplun=None):
|
||||
+ if wwpn and fcplun:
|
||||
+ d = ZFCPDevice(devnum, wwpn, fcplun)
|
||||
+ else:
|
||||
+ d = ZFCPNPIVDevice(devnum)
|
||||
+
|
||||
if d.online_device():
|
||||
self.fcpdevs.add(d)
|
||||
|
||||
--
|
||||
2.36.1
|
||||
|
||||
|
||||
From ee5b0cdc2393775925fbd9d32caed16eee33fcb0 Mon Sep 17 00:00:00 2001
|
||||
From: Jan Stodola <jstodola@redhat.com>
|
||||
Date: Sat, 20 Nov 2021 23:12:43 +0100
|
||||
Subject: [PATCH 8/8] Generate correct dracut boot arguments for NPIV devices
|
||||
|
||||
NPIV enabled devices need only the device ID. WWPNs/LUNs are discovered
|
||||
automatically by the kernel module.
|
||||
---
|
||||
blivet/devices/disk.py | 10 +++++++++-
|
||||
1 file changed, 9 insertions(+), 1 deletion(-)
|
||||
|
||||
diff --git a/blivet/devices/disk.py b/blivet/devices/disk.py
|
||||
index 67a01ba6..36278507 100644
|
||||
--- a/blivet/devices/disk.py
|
||||
+++ b/blivet/devices/disk.py
|
||||
@@ -577,7 +577,15 @@ class ZFCPDiskDevice(DiskDevice):
|
||||
'lun': self.fcp_lun}
|
||||
|
||||
def dracut_setup_args(self):
|
||||
- return set(["rd.zfcp=%s,%s,%s" % (self.hba_id, self.wwpn, self.fcp_lun,)])
|
||||
+ from ..zfcp import is_npiv_enabled
|
||||
+
|
||||
+ # zFCP devices in NPIV mode need only the device ID
|
||||
+ if is_npiv_enabled(self.hba_id):
|
||||
+ dracut_args = set(["rd.zfcp=%s" % self.hba_id])
|
||||
+ else:
|
||||
+ dracut_args = set(["rd.zfcp=%s,%s,%s" % (self.hba_id, self.wwpn, self.fcp_lun,)])
|
||||
+
|
||||
+ return dracut_args
|
||||
|
||||
|
||||
class DASDDevice(DiskDevice):
|
||||
--
|
||||
2.36.1
|
||||
|
107
SOURCES/0021-DDF-RAID-support-using-mdadm.patch
Normal file
107
SOURCES/0021-DDF-RAID-support-using-mdadm.patch
Normal file
@ -0,0 +1,107 @@
|
||||
From 898178047ac4bc97ddccb193cb0e11f7fdf18196 Mon Sep 17 00:00:00 2001
|
||||
From: Vojtech Trefny <vtrefny@redhat.com>
|
||||
Date: Wed, 17 Aug 2022 14:24:21 +0200
|
||||
Subject: [PATCH 1/3] Use MD populator instead of DM to handle DDF RAID format
|
||||
|
||||
---
|
||||
blivet/formats/dmraid.py | 2 +-
|
||||
blivet/formats/mdraid.py | 2 +-
|
||||
2 files changed, 2 insertions(+), 2 deletions(-)
|
||||
|
||||
diff --git a/blivet/formats/dmraid.py b/blivet/formats/dmraid.py
|
||||
index 2ba9dcfe5..ce15905dc 100644
|
||||
--- a/blivet/formats/dmraid.py
|
||||
+++ b/blivet/formats/dmraid.py
|
||||
@@ -43,7 +43,7 @@ class DMRaidMember(DeviceFormat):
|
||||
#
|
||||
# One problem that presents is the possibility of someone passing
|
||||
# a dmraid member to the MDRaidArrayDevice constructor.
|
||||
- _udev_types = ["adaptec_raid_member", "ddf_raid_member",
|
||||
+ _udev_types = ["adaptec_raid_member",
|
||||
"hpt37x_raid_member", "hpt45x_raid_member",
|
||||
"isw_raid_member",
|
||||
"jmicron_raid_member", "lsi_mega_raid_member",
|
||||
diff --git a/blivet/formats/mdraid.py b/blivet/formats/mdraid.py
|
||||
index 41ddef810..4aa3f3b07 100644
|
||||
--- a/blivet/formats/mdraid.py
|
||||
+++ b/blivet/formats/mdraid.py
|
||||
@@ -41,7 +41,7 @@ class MDRaidMember(DeviceFormat):
|
||||
""" An mdraid member disk. """
|
||||
_type = "mdmember"
|
||||
_name = N_("software RAID")
|
||||
- _udev_types = ["linux_raid_member"]
|
||||
+ _udev_types = ["linux_raid_member", "ddf_raid_member"]
|
||||
parted_flag = PARTITION_RAID
|
||||
_formattable = True # can be formatted
|
||||
_supported = True # is supported
|
||||
|
||||
From c487c6178ee9859163379946c1bdc3b2df1857b1 Mon Sep 17 00:00:00 2001
|
||||
From: Vojtech Trefny <vtrefny@redhat.com>
|
||||
Date: Wed, 17 Aug 2022 14:24:58 +0200
|
||||
Subject: [PATCH 2/3] Do not read DDF RAID UUID from udev
|
||||
|
||||
The UUID we get from udev isn't the array UUID, we need to get
|
||||
that using libblockdev.
|
||||
---
|
||||
blivet/populator/helpers/mdraid.py | 16 ++++++++++------
|
||||
1 file changed, 10 insertions(+), 6 deletions(-)
|
||||
|
||||
diff --git a/blivet/populator/helpers/mdraid.py b/blivet/populator/helpers/mdraid.py
|
||||
index 76aebf250..9bec11efb 100644
|
||||
--- a/blivet/populator/helpers/mdraid.py
|
||||
+++ b/blivet/populator/helpers/mdraid.py
|
||||
@@ -98,17 +98,21 @@ class MDFormatPopulator(FormatPopulator):
|
||||
|
||||
def _get_kwargs(self):
|
||||
kwargs = super(MDFormatPopulator, self)._get_kwargs()
|
||||
- try:
|
||||
- # ID_FS_UUID contains the array UUID
|
||||
- kwargs["md_uuid"] = udev.device_get_uuid(self.data)
|
||||
- except KeyError:
|
||||
- log.warning("mdraid member %s has no md uuid", udev.device_get_name(self.data))
|
||||
+ kwargs["biosraid"] = udev.device_is_biosraid_member(self.data)
|
||||
+ if not kwargs["biosraid"]:
|
||||
+ try:
|
||||
+ # ID_FS_UUID contains the array UUID
|
||||
+ kwargs["md_uuid"] = udev.device_get_uuid(self.data)
|
||||
+ except KeyError:
|
||||
+ log.warning("mdraid member %s has no md uuid", udev.device_get_name(self.data))
|
||||
+ else:
|
||||
+ # for BIOS RAIDs we can't get the UUID from udev, we'll get it from mdadm in `run` below
|
||||
+ kwargs["md_uuid"] = None
|
||||
|
||||
# reset the uuid to the member-specific value
|
||||
# this will be None for members of v0 metadata arrays
|
||||
kwargs["uuid"] = udev.device_get_md_device_uuid(self.data)
|
||||
|
||||
- kwargs["biosraid"] = udev.device_is_biosraid_member(self.data)
|
||||
return kwargs
|
||||
|
||||
def run(self):
|
||||
|
||||
From 325681bcd40fc4f0e13a4d23c889e1f7cc043cc1 Mon Sep 17 00:00:00 2001
|
||||
From: Vojtech Trefny <vtrefny@redhat.com>
|
||||
Date: Thu, 17 Mar 2022 15:48:25 +0100
|
||||
Subject: [PATCH 3/3] Do not crash when a disk populator doesn't return kwargs
|
||||
|
||||
This happens when trying to use Blivet on a system with a BIOS
|
||||
RAID without dmraid installed. Because we don't fully support
|
||||
BIOS RAIDs using MD the MDBiosRaidDevicePopulator helper fails
|
||||
to get kwargs for the BIOS RAID "disk" and populate fails.
|
||||
---
|
||||
blivet/populator/helpers/disk.py | 2 ++
|
||||
1 file changed, 2 insertions(+)
|
||||
|
||||
diff --git a/blivet/populator/helpers/disk.py b/blivet/populator/helpers/disk.py
|
||||
index 2e5026f7e..9db7b810d 100644
|
||||
--- a/blivet/populator/helpers/disk.py
|
||||
+++ b/blivet/populator/helpers/disk.py
|
||||
@@ -68,6 +68,8 @@ def run(self):
|
||||
log_method_call(self, name=name)
|
||||
|
||||
kwargs = self._get_kwargs()
|
||||
+ if not kwargs:
|
||||
+ return
|
||||
device = self._device_class(name, **kwargs)
|
||||
self._devicetree._add_device(device)
|
||||
return device
|
@ -23,7 +23,7 @@ Version: 3.4.0
|
||||
|
||||
#%%global prerelease .b2
|
||||
# prerelease, if defined, should be something like .a1, .b1, .b2.dev1, or .c2
|
||||
Release: 9%{?prerelease}%{?dist}
|
||||
Release: 13%{?prerelease}%{?dist}
|
||||
Epoch: 1
|
||||
License: LGPLv2+
|
||||
%global realname blivet
|
||||
@ -42,6 +42,15 @@ Patch8: 0009-Improve-error-message-printed-for-missing-dependecie.patch
|
||||
Patch9: 0010-Use-bigger-chunk-size-for-thinpools-bigger-than-15.8.patch
|
||||
Patch10: 0011-iscsi-Replace-all-log_exception_info-calls-with-log.patch
|
||||
Patch11: 0012-PO-update.patch
|
||||
Patch12: 0013-Fix-getting-PV-info-in-LVMPhysicalVolume-from-the-ca.patch
|
||||
Patch13: 0014-Do-not-crash-when-changing-disklabel-on-disks-with-a.patch
|
||||
Patch14: 0015-ActionDestroyDevice-should-not-obsolete-ActionRemove.patch
|
||||
Patch15: 0016-Correctly-set-vg_name-after-adding-removing-a-PV-fro.patch
|
||||
Patch16: 0017-Use-LVM-PV-format-current_size-in-LVMVolumeGroupDevi.patch
|
||||
Patch17: 0018-Add-support-for-creating-LVM-cache-pools.patch
|
||||
Patch18: 0019-Fix-util.virt_detect-on-Xen.patch
|
||||
Patch19: 0020-Add-support-for-NPIV-enabled-zFCP-devices.patch
|
||||
Patch20: 0021-DDF-RAID-support-using-mdadm.patch
|
||||
|
||||
# Versions of required components (done so we make sure the buildrequires
|
||||
# match the requires versions of things).
|
||||
@ -204,6 +213,32 @@ configuration.
|
||||
%endif
|
||||
|
||||
%changelog
|
||||
* Thu Aug 18 2022 Vojtech Trefny <vtrefny@redhat.com> - 3.4.0-13
|
||||
- DDF RAID support using mdadm
|
||||
Resolves: rhbz#2063791
|
||||
|
||||
* Mon Jun 20 2022 Vojtech Trefny <vtrefny@redhat.com> - 3.4.0-12
|
||||
- Add support for NPIV-enabled zFCP devices
|
||||
Resolves: rhbz#1497087
|
||||
|
||||
* Thu Jun 02 2022 Vojtech Trefny <vtrefny@redhat.com> - 3.4.0-11
|
||||
- Fix running gating tests on AWS/Xen machines
|
||||
Resolves: rhbz#2093207
|
||||
|
||||
* Thu Jun 02 2022 Vojtech Trefny <vtrefny@redhat.com> - 3.4.0-10
|
||||
- Fix getting PV info in LVMPhysicalVolume from the cache
|
||||
Resolves: rhbz#2079220
|
||||
- Do not crash when changing disklabel on disks with active devices
|
||||
Resolves: rhbz#2078801
|
||||
- ActionDestroyDevice should not obsolete ActionRemoveMember
|
||||
Resolves: rhbz#2076958
|
||||
- Correctly set vg_name after adding/removing a PV from a VG
|
||||
Resolves: rhbz#2081276
|
||||
- Use LVM PV format current_size in LVMVolumeGroupDevice._remove
|
||||
Related: rhbz#2081276
|
||||
- Add support for creating LVM cache pools
|
||||
Resolves: rhbz#2055198
|
||||
|
||||
* Thu Jan 10 2022 Vojtech Trefny <vtrefny@redhat.com> - 3.4.0-9
|
||||
- Translation update
|
||||
Resolves: rhbz#2003050
|
||||
|
Loading…
Reference in New Issue
Block a user