From a4e96fd8f3f0b5416783237c1cb6ee87e7eff23d Mon Sep 17 00:00:00 2001 From: Mariusz Tkaczyk Date: Fri, 8 Feb 2019 11:07:10 +0100 Subject: [RHEL7.7 PATCH 12/24] imsm: finish recovery when drive with rebuild fails Commit d7a1fda2769b ("imsm: update metadata correctly while raid10 double degradation") resolves main Imsm double degradation problems but it omits one case. Now metadata hangs in the rebuilding state if the drive under rebuild is removed during recovery from double degradation. The root cause of this problem is comparing new map_state with current and if they both are degraded assuming that nothing new happens. Don't rely on map states, just check if device is failed. If the drive under rebuild fails then finish migration, in other cases update map state only (second fail means that destination map state can't be normal). To avoid problems with reassembling move end_migration (called after double degradation successful recovery) after check if recovery really finished, for details see (7ce057018 "imsm: fix: rebuild does not continue after reboot"). Remove redundant code responsible for finishing rebuild process. Function end_migration do exactly the same. Set last_checkpoint to 0, to prepare it for the next rebuild. Signed-off-by: Mariusz Tkaczyk Signed-off-by: Jes Sorensen --- super-intel.c | 26 +++++++++++--------------- 1 file changed, 11 insertions(+), 15 deletions(-) diff --git a/super-intel.c b/super-intel.c index d2035cc..38a1b6c 100644 --- a/super-intel.c +++ b/super-intel.c @@ -8560,26 +8560,22 @@ static void imsm_set_disk(struct active_array *a, int n, int state) } if (is_rebuilding(dev)) { dprintf_cont("while rebuilding "); - if (map->map_state != map_state) { - dprintf_cont("map state change "); + if (state & DS_FAULTY) { + dprintf_cont("removing failed drive "); if (n == map->failed_disk_num) { dprintf_cont("end migration"); end_migration(dev, super, map_state); + a->last_checkpoint = 0; } else { - dprintf_cont("raid10 double degradation, map state change"); + dprintf_cont("fail detected during rebuild, changing map state"); map->map_state = map_state; } super->updates_pending++; - } else if (!rebuild_done) - break; - else if (n == map->failed_disk_num) { - /* r10 double degraded to degraded transition */ - dprintf_cont("raid10 double degradation end migration"); - end_migration(dev, super, map_state); - a->last_checkpoint = 0; - super->updates_pending++; } + if (!rebuild_done) + break; + /* check if recovery is really finished */ for (mdi = a->info.devs; mdi ; mdi = mdi->next) if (mdi->recovery_start != MaxSector) { @@ -8588,7 +8584,7 @@ static void imsm_set_disk(struct active_array *a, int n, int state) } if (recovery_not_finished) { dprintf_cont("\n"); - dprintf_cont("Rebuild has not finished yet, map state changes only if raid10 double degradation happens"); + dprintf_cont("Rebuild has not finished yet"); if (a->last_checkpoint < mdi->recovery_start) { a->last_checkpoint = mdi->recovery_start; @@ -8598,9 +8594,9 @@ static void imsm_set_disk(struct active_array *a, int n, int state) } dprintf_cont(" Rebuild done, still degraded"); - dev->vol.migr_state = 0; - set_migr_type(dev, 0); - dev->vol.curr_migr_unit = 0; + end_migration(dev, super, map_state); + a->last_checkpoint = 0; + super->updates_pending++; for (i = 0; i < map->num_members; i++) { int idx = get_imsm_ord_tbl_ent(dev, i, MAP_0); -- 2.7.5