Modify 0021-RHBZ-548874-add-find-multipaths.patch Modify 0022-RHBZ-557845-RHEL5-style-partitions.patch Add 0025-RHBZ-508827-update-multipathd-manpage.patch through 0101-RHBZ-631009-disable-udev-disk-rules-on-reload.patch * sync with current state of RHEL6. Next release should include a updated source tarball with most of these fixes rolled in. Add 0102-RHBZ-690828-systemd-unit-file.patch * Add Jóhann B. Guðmundsson's unit file for systemd. * Add sub-package sysvinit for SysV init script. Resolves: bz #690828
52 lines
2.1 KiB
Diff
52 lines
2.1 KiB
Diff
---
|
|
multipath/multipath.conf.5 | 26 +++++++++++++++++++-------
|
|
1 file changed, 19 insertions(+), 7 deletions(-)
|
|
|
|
Index: multipath-tools/multipath/multipath.conf.5
|
|
===================================================================
|
|
--- multipath-tools.orig/multipath/multipath.conf.5
|
|
+++ multipath-tools/multipath/multipath.conf.5
|
|
@@ -39,9 +39,8 @@ section in which they occor.
|
|
The following \fIsection\fP keywords are recognized:
|
|
.TP 17
|
|
.B defaults
|
|
-This section defines default values for attributes which are used
|
|
-whenever no specific setting is given in the appropriate device or
|
|
-multipath sections.
|
|
+This section defines default settings for devices-mapper-multipath. These
|
|
+values can be overwritten by the devices and multipaths sections.
|
|
.TP
|
|
.B blacklist
|
|
This section defines which devices should be excluded from the
|
|
@@ -54,13 +53,26 @@ multipath topology discovery, despite be
|
|
section.
|
|
.TP
|
|
.B multipaths
|
|
-This section defines the multipath topologies. They are indexed by a
|
|
-\fIWorld Wide Identifier\fR(wwid), which is the result of the
|
|
-\fIgetuid_callout\fR program.
|
|
+This section defines the settings for individual multipath devices.
|
|
+These values overwrite what is specified in the defaults and devices
|
|
+section of the configuration file.
|
|
+The devices are identified by the \fIwwid\fR keyword, which is a regular
|
|
+expression that must match the result of the \fIgetuid_callout\fR program.
|
|
.TP
|
|
.B devices
|
|
-This section defines the device-specific settings.
|
|
+This section defines the settings for individual storage controller types.
|
|
+These value overwrite what is specified in the defaults section of the
|
|
+configuration file.
|
|
+These controller types are identified by the \fIvendor\fR, \fIproduct\fR, and
|
|
+\fIrevision\fR keywords, which are regular expressions that must match the
|
|
+sysfs information about this device.
|
|
+If you are using a storage array that is not supported by default, you may need
|
|
+to create a devices subsection for your array.
|
|
.RE
|
|
+.P
|
|
+The priority of configuration in multipath.conf is:
|
|
+.br
|
|
+\fImultipaths\fR is greater than \fIdevices\fR is greater that \fIdefaults\fR
|
|
.LP
|
|