| .. SPDX-License-Identifier: GPL-2.0
 | ||
| 
 | ||
| ===============================================================
 | ||
| Intel(R) Dynamic Platform and Thermal Framework Sysfs Interface
 | ||
| ===============================================================
 | ||
| 
 | ||
| :Copyright: © 2022 Intel Corporation
 | ||
| 
 | ||
| :Author: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
 | ||
| 
 | ||
| Introduction
 | ||
| ------------
 | ||
| 
 | ||
| Intel(R) Dynamic Platform and Thermal Framework (DPTF) is a platform
 | ||
| level hardware/software solution for power and thermal management.
 | ||
| 
 | ||
| As a container for multiple power/thermal technologies, DPTF provides
 | ||
| a coordinated approach for different policies to effect the hardware
 | ||
| state of a system.
 | ||
| 
 | ||
| Since it is a platform level framework, this has several components.
 | ||
| Some parts of the technology is implemented in the firmware and uses
 | ||
| ACPI and PCI devices to expose various features for monitoring and
 | ||
| control. Linux has a set of kernel drivers exposing hardware interface
 | ||
| to user space. This allows user space thermal solutions like
 | ||
| "Linux Thermal Daemon" to read platform specific thermal and power
 | ||
| tables to deliver adequate performance while keeping the system under
 | ||
| thermal limits.
 | ||
| 
 | ||
| DPTF ACPI Drivers interface
 | ||
| ----------------------------
 | ||
| 
 | ||
| :file:`/sys/bus/platform/devices/<N>/uuids`, where <N>
 | ||
| =INT3400|INTC1040|INTC1041|INTC10A0
 | ||
| 
 | ||
| ``available_uuids`` (RO)
 | ||
| 	A set of UUIDs strings presenting available policies
 | ||
| 	which should be notified to the firmware when the
 | ||
| 	user space can support those policies.
 | ||
| 
 | ||
| 	UUID strings:
 | ||
| 
 | ||
| 	"42A441D6-AE6A-462b-A84B-4A8CE79027D3" : Passive 1
 | ||
| 
 | ||
| 	"3A95C389-E4B8-4629-A526-C52C88626BAE" : Active
 | ||
| 
 | ||
| 	"97C68AE7-15FA-499c-B8C9-5DA81D606E0A" : Critical
 | ||
| 
 | ||
| 	"63BE270F-1C11-48FD-A6F7-3AF253FF3E2D" : Adaptive performance
 | ||
| 
 | ||
| 	"5349962F-71E6-431D-9AE8-0A635B710AEE" : Emergency call
 | ||
| 
 | ||
| 	"9E04115A-AE87-4D1C-9500-0F3E340BFE75" : Passive 2
 | ||
| 
 | ||
| 	"F5A35014-C209-46A4-993A-EB56DE7530A1" : Power Boss
 | ||
| 
 | ||
| 	"6ED722A7-9240-48A5-B479-31EEF723D7CF" : Virtual Sensor
 | ||
| 
 | ||
| 	"16CAF1B7-DD38-40ED-B1C1-1B8A1913D531" : Cooling mode
 | ||
| 
 | ||
| 	"BE84BABF-C4D4-403D-B495-3128FD44dAC1" : HDC
 | ||
| 
 | ||
| ``current_uuid`` (RW)
 | ||
| 	User space can write strings from available UUIDs, one at a
 | ||
| 	time.
 | ||
| 
 | ||
| :file:`/sys/bus/platform/devices/<N>/`, where <N>
 | ||
| =INT3400|INTC1040|INTC1041|INTC10A0
 | ||
| 
 | ||
| ``imok`` (WO)
 | ||
| 	User space daemon write 1 to respond to firmware event
 | ||
| 	for sending keep alive notification. User space receives
 | ||
| 	THERMAL_EVENT_KEEP_ALIVE kobject uevent notification when
 | ||
| 	firmware calls for user space to respond with imok ACPI
 | ||
| 	method.
 | ||
| 
 | ||
| ``odvp*`` (RO)
 | ||
| 	Firmware thermal status variable values. Thermal tables
 | ||
| 	calls for different processing based on these variable
 | ||
| 	values.
 | ||
| 
 | ||
| ``data_vault`` (RO)
 | ||
| 	Binary thermal table. Refer to
 | ||
| 	https:/github.com/intel/thermal_daemon for decoding
 | ||
| 	thermal table.
 | ||
| 
 | ||
| ``production_mode`` (RO)
 | ||
| 	When different from zero, manufacturer locked thermal configuration
 | ||
| 	from further changes.
 | ||
| 
 | ||
| ACPI Thermal Relationship table interface
 | ||
| ------------------------------------------
 | ||
| 
 | ||
| :file:`/dev/acpi_thermal_rel`
 | ||
| 
 | ||
| 	This device provides IOCTL interface to read standard ACPI
 | ||
| 	thermal relationship tables via ACPI methods _TRT and _ART.
 | ||
| 	These IOCTLs are defined in
 | ||
| 	drivers/thermal/intel/int340x_thermal/acpi_thermal_rel.h
 | ||
| 
 | ||
| 	IOCTLs:
 | ||
| 
 | ||
| 	ACPI_THERMAL_GET_TRT_LEN: Get length of TRT table
 | ||
| 
 | ||
| 	ACPI_THERMAL_GET_ART_LEN: Get length of ART table
 | ||
| 
 | ||
| 	ACPI_THERMAL_GET_TRT_COUNT: Number of records in TRT table
 | ||
| 
 | ||
| 	ACPI_THERMAL_GET_ART_COUNT: Number of records in ART table
 | ||
| 
 | ||
| 	ACPI_THERMAL_GET_TRT: Read binary TRT table, length to read is
 | ||
| 	provided via argument to ioctl().
 | ||
| 
 | ||
| 	ACPI_THERMAL_GET_ART: Read binary ART table, length to read is
 | ||
| 	provided via argument to ioctl().
 | ||
| 
 | ||
| DPTF ACPI Sensor drivers
 | ||
| -------------------------
 | ||
| 
 | ||
| DPTF Sensor drivers are presented as standard thermal sysfs thermal_zone.
 | ||
| 
 | ||
| 
 | ||
| DPTF ACPI Cooling drivers
 | ||
| --------------------------
 | ||
| 
 | ||
| DPTF cooling drivers are presented as standard thermal sysfs cooling_device.
 | ||
| 
 | ||
| 
 | ||
| DPTF Processor thermal PCI Driver interface
 | ||
| --------------------------------------------
 | ||
| 
 | ||
| :file:`/sys/bus/pci/devices/0000\:00\:04.0/power_limits/`
 | ||
| 
 | ||
| Refer to Documentation/power/powercap/powercap.rst for powercap
 | ||
| ABI.
 | ||
| 
 | ||
| ``power_limit_0_max_uw`` (RO)
 | ||
| 	Maximum powercap sysfs constraint_0_power_limit_uw for Intel RAPL
 | ||
| 
 | ||
| ``power_limit_0_step_uw`` (RO)
 | ||
| 	Power limit increment/decrements for Intel RAPL constraint 0 power limit
 | ||
| 
 | ||
| ``power_limit_0_min_uw`` (RO)
 | ||
| 	Minimum powercap sysfs constraint_0_power_limit_uw for Intel RAPL
 | ||
| 
 | ||
| ``power_limit_0_tmin_us`` (RO)
 | ||
| 	Minimum powercap sysfs constraint_0_time_window_us for Intel RAPL
 | ||
| 
 | ||
| ``power_limit_0_tmax_us`` (RO)
 | ||
| 	Maximum powercap sysfs constraint_0_time_window_us for Intel RAPL
 | ||
| 
 | ||
| ``power_limit_1_max_uw`` (RO)
 | ||
| 	Maximum powercap sysfs constraint_1_power_limit_uw for Intel RAPL
 | ||
| 
 | ||
| ``power_limit_1_step_uw`` (RO)
 | ||
| 	Power limit increment/decrements for Intel RAPL constraint 1 power limit
 | ||
| 
 | ||
| ``power_limit_1_min_uw`` (RO)
 | ||
| 	Minimum powercap sysfs constraint_1_power_limit_uw for Intel RAPL
 | ||
| 
 | ||
| ``power_limit_1_tmin_us`` (RO)
 | ||
| 	Minimum powercap sysfs constraint_1_time_window_us for Intel RAPL
 | ||
| 
 | ||
| ``power_limit_1_tmax_us`` (RO)
 | ||
| 	Maximum powercap sysfs constraint_1_time_window_us for Intel RAPL
 | ||
| 
 | ||
| ``power_floor_status`` (RO)
 | ||
| 	When set to 1, the power floor of the system in the current
 | ||
| 	configuration has been reached.  It needs to be reconfigured to allow
 | ||
| 	power to be reduced any further.
 | ||
| 
 | ||
| ``power_floor_enable`` (RW)
 | ||
| 	When set to 1, enable reading and notification of the power floor
 | ||
| 	status. Notifications are triggered for the power_floor_status
 | ||
| 	attribute value changes.
 | ||
| 
 | ||
| :file:`/sys/bus/pci/devices/0000\:00\:04.0/`
 | ||
| 
 | ||
| ``tcc_offset_degree_celsius`` (RW)
 | ||
| 	TCC offset from the critical temperature where hardware will throttle
 | ||
| 	CPU.
 | ||
| 
 | ||
| :file:`/sys/bus/pci/devices/0000\:00\:04.0/workload_request`
 | ||
| 
 | ||
| ``workload_available_types`` (RO)
 | ||
| 	Available workload types. User space can specify one of the workload type
 | ||
| 	it is currently executing via workload_type. For example: idle, bursty,
 | ||
| 	sustained etc.
 | ||
| 
 | ||
| ``workload_type`` (RW)
 | ||
| 	User space can specify any one of the available workload type using
 | ||
| 	this interface.
 | ||
| 
 | ||
| DPTF Processor thermal RFIM interface
 | ||
| --------------------------------------------
 | ||
| 
 | ||
| RFIM interface allows adjustment of FIVR (Fully Integrated Voltage Regulator),
 | ||
| DDR (Double Data Rate) and DLVR (Digital Linear Voltage Regulator)
 | ||
| frequencies to avoid RF interference with WiFi and 5G.
 | ||
| 
 | ||
| Switching voltage regulators (VR) generate radiated EMI or RFI at the
 | ||
| fundamental frequency and its harmonics. Some harmonics may interfere
 | ||
| with very sensitive wireless receivers such as Wi-Fi and cellular that
 | ||
| are integrated into host systems like notebook PCs.  One of mitigation
 | ||
| methods is requesting SOC integrated VR (IVR) switching frequency to a
 | ||
| small % and shift away the switching noise harmonic interference from
 | ||
| radio channels.  OEM or ODMs can use the driver to control SOC IVR
 | ||
| operation within the range where it does not impact IVR performance.
 | ||
| 
 | ||
| Some products use DLVR instead of FIVR as switching voltage regulator.
 | ||
| In this case attributes of DLVR must be adjusted instead of FIVR.
 | ||
| 
 | ||
| While shifting the frequencies additional clock noise can be introduced,
 | ||
| which is compensated by adjusting Spread spectrum percent. This helps
 | ||
| to reduce the clock noise to meet regulatory compliance. This spreading
 | ||
| % increases bandwidth of signal transmission and hence reduces the
 | ||
| effects of interference, noise and signal fading.
 | ||
| 
 | ||
| DRAM devices of DDR IO interface and their power plane can generate EMI
 | ||
| at the data rates. Similar to IVR control mechanism, Intel offers a
 | ||
| mechanism by which DDR data rates can be changed if several conditions
 | ||
| are met: there is strong RFI interference because of DDR; CPU power
 | ||
| management has no other restriction in changing DDR data rates;
 | ||
| PC ODMs enable this feature (real time DDR RFI Mitigation referred to as
 | ||
| DDR-RFIM) for Wi-Fi from BIOS.
 | ||
| 
 | ||
| 
 | ||
| FIVR attributes
 | ||
| 
 | ||
| :file:`/sys/bus/pci/devices/0000\:00\:04.0/fivr/`
 | ||
| 
 | ||
| ``vco_ref_code_lo`` (RW)
 | ||
| 	The VCO reference code is an 11-bit field and controls the FIVR
 | ||
| 	switching frequency. This is the 3-bit LSB field.
 | ||
| 
 | ||
| ``vco_ref_code_hi`` (RW)
 | ||
| 	The VCO reference code is an 11-bit field and controls the FIVR
 | ||
| 	switching frequency. This is the 8-bit MSB field.
 | ||
| 
 | ||
| ``spread_spectrum_pct`` (RW)
 | ||
| 	Set the FIVR spread spectrum clocking percentage
 | ||
| 
 | ||
| ``spread_spectrum_clk_enable`` (RW)
 | ||
| 	Enable/disable of the FIVR spread spectrum clocking feature
 | ||
| 
 | ||
| ``rfi_vco_ref_code`` (RW)
 | ||
| 	This field is a read only status register which reflects the
 | ||
| 	current FIVR switching frequency
 | ||
| 
 | ||
| ``fivr_fffc_rev`` (RW)
 | ||
| 	This field indicated the revision of the FIVR HW.
 | ||
| 
 | ||
| 
 | ||
| DVFS attributes
 | ||
| 
 | ||
| :file:`/sys/bus/pci/devices/0000\:00\:04.0/dvfs/`
 | ||
| 
 | ||
| ``rfi_restriction_run_busy`` (RW)
 | ||
| 	Request the restriction of specific DDR data rate and set this
 | ||
| 	value 1. Self reset to 0 after operation.
 | ||
| 
 | ||
| ``rfi_restriction_err_code`` (RW)
 | ||
| 	0 :Request is accepted, 1:Feature disabled,
 | ||
| 	2: the request restricts more points than it is allowed
 | ||
| 
 | ||
| ``rfi_restriction_data_rate_Delta`` (RW)
 | ||
| 	Restricted DDR data rate for RFI protection: Lower Limit
 | ||
| 
 | ||
| ``rfi_restriction_data_rate_Base`` (RW)
 | ||
| 	Restricted DDR data rate for RFI protection: Upper Limit
 | ||
| 
 | ||
| ``ddr_data_rate_point_0`` (RO)
 | ||
| 	DDR data rate selection 1st point
 | ||
| 
 | ||
| ``ddr_data_rate_point_1`` (RO)
 | ||
| 	DDR data rate selection 2nd point
 | ||
| 
 | ||
| ``ddr_data_rate_point_2`` (RO)
 | ||
| 	DDR data rate selection 3rd point
 | ||
| 
 | ||
| ``ddr_data_rate_point_3`` (RO)
 | ||
| 	DDR data rate selection 4th point
 | ||
| 
 | ||
| ``rfi_disable (RW)``
 | ||
| 	Disable DDR rate change feature
 | ||
| 
 | ||
| DLVR attributes
 | ||
| 
 | ||
| :file:`/sys/bus/pci/devices/0000\:00\:04.0/dlvr/`
 | ||
| 
 | ||
| ``dlvr_hardware_rev`` (RO)
 | ||
| 	DLVR hardware revision.
 | ||
| 
 | ||
| ``dlvr_freq_mhz`` (RO)
 | ||
| 	Current DLVR PLL frequency in MHz.
 | ||
| 
 | ||
| ``dlvr_freq_select`` (RW)
 | ||
| 	Sets DLVR PLL clock frequency. Once set, and enabled via
 | ||
| 	dlvr_rfim_enable, the dlvr_freq_mhz will show the current
 | ||
| 	DLVR PLL frequency.
 | ||
| 
 | ||
| ``dlvr_pll_busy`` (RO)
 | ||
| 	PLL can't accept frequency change when set.
 | ||
| 
 | ||
| ``dlvr_rfim_enable`` (RW)
 | ||
| 	0: Disable RF frequency hopping, 1: Enable RF frequency hopping.
 | ||
| 
 | ||
| ``dlvr_spread_spectrum_pct`` (RW)
 | ||
| 	Sets DLVR spread spectrum percent value.
 | ||
| 
 | ||
| ``dlvr_control_mode`` (RW)
 | ||
|         Specifies how frequencies are spread using spread spectrum.
 | ||
|         0: Down spread,
 | ||
|         1: Spread in the Center.
 | ||
| 
 | ||
| ``dlvr_control_lock`` (RW)
 | ||
|     1: future writes are ignored.
 | ||
| 
 | ||
| DPTF Power supply and Battery Interface
 | ||
| ----------------------------------------
 | ||
| 
 | ||
| Refer to Documentation/ABI/testing/sysfs-platform-dptf
 | ||
| 
 | ||
| DPTF Fan Control
 | ||
| ----------------------------------------
 | ||
| 
 | ||
| Refer to Documentation/admin-guide/acpi/fan_performance_states.rst
 | ||
| 
 | ||
| Workload Type Hints
 | ||
| ----------------------------------------
 | ||
| 
 | ||
| The firmware in Meteor Lake processor generation is capable of identifying
 | ||
| workload type and passing hints regarding it to the OS. A special sysfs
 | ||
| interface is provided to allow user space to obtain workload type hints from
 | ||
| the firmware and control the rate at which they are provided.
 | ||
| 
 | ||
| User space can poll attribute "workload_type_index" for the current hint or
 | ||
| can receive a notification whenever the value of this attribute is updated.
 | ||
| 
 | ||
| file:`/sys/bus/pci/devices/0000:00:04.0/workload_hint/`
 | ||
| Segment 0, bus 0, device 4, function 0 is reserved for the processor thermal
 | ||
| device on all Intel client processors. So, the above path doesn't change
 | ||
| based on the processor generation.
 | ||
| 
 | ||
| ``workload_hint_enable`` (RW)
 | ||
| 	Enable firmware to send workload type hints to user space.
 | ||
| 
 | ||
| ``notification_delay_ms`` (RW)
 | ||
| 	Minimum delay in milliseconds before firmware will notify OS. This is
 | ||
| 	for the rate control of notifications. This delay is between changing
 | ||
| 	the workload type prediction in the firmware and notifying the OS about
 | ||
| 	the change. The default delay is 1024 ms. The delay of 0 is invalid.
 | ||
| 	The delay is rounded up to the nearest power of 2 to simplify firmware
 | ||
| 	programming of the delay value. The read of notification_delay_ms
 | ||
| 	attribute shows the effective value used.
 | ||
| 
 | ||
| ``workload_type_index`` (RO)
 | ||
| 	Predicted workload type index. User space can get notification of
 | ||
| 	change via existing sysfs attribute change notification mechanism.
 | ||
| 
 | ||
| 	The supported index values and their meaning for the Meteor Lake
 | ||
| 	processor generation are as follows:
 | ||
| 
 | ||
| 	0 -  Idle: System performs no tasks, power and idle residency are
 | ||
| 		consistently low for long periods of time.
 | ||
| 
 | ||
| 	1 – Battery Life: Power is relatively low, but the processor may
 | ||
| 		still be actively performing a task, such as video playback for
 | ||
| 		a long period of time.
 | ||
| 
 | ||
| 	2 – Sustained: Power level that is relatively high for a long period
 | ||
| 		of time, with very few to no periods of idleness, which will
 | ||
| 		eventually exhaust RAPL Power Limit 1 and 2.
 | ||
| 
 | ||
| 	3 – Bursty: Consumes a relatively constant average amount of power, but
 | ||
| 		periods of relative idleness are interrupted by bursts of
 | ||
| 		activity. The bursts are relatively short and the periods of
 | ||
| 		relative idleness between them typically prevent RAPL Power
 | ||
| 		Limit 1 from being exhausted.
 | ||
| 
 | ||
| 	4 – Unknown: Can't classify.
 |