76 lines
		
	
	
		
			2.2 KiB
		
	
	
	
		
			ReStructuredText
		
	
	
	
	
	
			
		
		
	
	
			76 lines
		
	
	
		
			2.2 KiB
		
	
	
	
		
			ReStructuredText
		
	
	
	
	
	
.. SPDX-License-Identifier: GPL-2.0
 | 
						|
 | 
						|
Kernel driver pli1209bc
 | 
						|
=======================
 | 
						|
 | 
						|
Supported chips:
 | 
						|
 | 
						|
  * Digital Supervisor PLI1209BC
 | 
						|
 | 
						|
    Prefix: 'pli1209bc'
 | 
						|
 | 
						|
    Addresses scanned: 0x50 - 0x5F
 | 
						|
 | 
						|
    Datasheet: https://www.vicorpower.com/documents/datasheets/ds-PLI1209BCxyzz-VICOR.pdf
 | 
						|
 | 
						|
Authors:
 | 
						|
    - Marcello Sylvester Bauer <sylv@sylv.io>
 | 
						|
 | 
						|
Description
 | 
						|
-----------
 | 
						|
 | 
						|
The Vicor PLI1209BC is an isolated digital power system supervisor that provides
 | 
						|
a communication interface between a host processor and one Bus Converter Module
 | 
						|
(BCM). The PLI communicates with a system controller via a PMBus compatible
 | 
						|
interface over an isolated UART interface. Through the PLI, the host processor
 | 
						|
can configure, set protection limits, and monitor the BCM.
 | 
						|
 | 
						|
Sysfs entries
 | 
						|
-------------
 | 
						|
 | 
						|
======================= ========================================================
 | 
						|
in1_label		"vin2"
 | 
						|
in1_input		Input voltage.
 | 
						|
in1_rated_min		Minimum rated input voltage.
 | 
						|
in1_rated_max		Maximum rated input voltage.
 | 
						|
in1_max			Maximum input voltage.
 | 
						|
in1_max_alarm		Input voltage high alarm.
 | 
						|
in1_crit		Critical input voltage.
 | 
						|
in1_crit_alarm		Input voltage critical alarm.
 | 
						|
 | 
						|
in2_label		"vout2"
 | 
						|
in2_input		Output voltage.
 | 
						|
in2_rated_min		Minimum rated output voltage.
 | 
						|
in2_rated_max		Maximum rated output voltage.
 | 
						|
in2_alarm		Output voltage alarm
 | 
						|
 | 
						|
curr1_label		"iin2"
 | 
						|
curr1_input		Input current.
 | 
						|
curr1_max		Maximum input current.
 | 
						|
curr1_max_alarm		Maximum input current high alarm.
 | 
						|
curr1_crit		Critical input current.
 | 
						|
curr1_crit_alarm	Input current critical alarm.
 | 
						|
 | 
						|
curr2_label		"iout2"
 | 
						|
curr2_input		Output current.
 | 
						|
curr2_crit		Critical output current.
 | 
						|
curr2_crit_alarm	Output current critical alarm.
 | 
						|
curr2_max		Maximum output current.
 | 
						|
curr2_max_alarm		Output current high alarm.
 | 
						|
 | 
						|
power1_label		"pin2"
 | 
						|
power1_input		Input power.
 | 
						|
power1_alarm		Input power alarm.
 | 
						|
 | 
						|
power2_label		"pout2"
 | 
						|
power2_input		Output power.
 | 
						|
power2_rated_max	Maximum rated output power.
 | 
						|
 | 
						|
temp1_input		Die temperature.
 | 
						|
temp1_alarm		Die temperature alarm.
 | 
						|
temp1_max		Maximum die temperature.
 | 
						|
temp1_max_alarm		Die temperature high alarm.
 | 
						|
temp1_crit		Critical die temperature.
 | 
						|
temp1_crit_alarm	Die temperature critical alarm.
 | 
						|
======================= ========================================================
 |