| What:		/sys/bus/iio/devices/iio:deviceX/in_count_count_mode_available
 | |
| What:		/sys/bus/iio/devices/iio:deviceX/in_count_noise_error_available
 | |
| What:		/sys/bus/iio/devices/iio:deviceX/in_count_quadrature_mode_available
 | |
| What:		/sys/bus/iio/devices/iio:deviceX/in_index_index_polarity_available
 | |
| What:		/sys/bus/iio/devices/iio:deviceX/in_index_synchronous_mode_available
 | |
| KernelVersion:	4.10
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Discrete set of available values for the respective counter
 | |
| 		configuration are listed in this file.
 | |
| 
 | |
| What:		/sys/bus/iio/devices/iio:deviceX/in_countY_count_mode
 | |
| KernelVersion:	4.10
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Count mode for channel Y. Four count modes are available:
 | |
| 		normal, range limit, non-recycle, and modulo-n. The preset value
 | |
| 		for channel Y is used by the count mode where required.
 | |
| 
 | |
| 		Normal:
 | |
| 			Counting is continuous in either direction.
 | |
| 
 | |
| 		Range Limit:
 | |
| 			An upper or lower limit is set, mimicking limit switches
 | |
| 			in the mechanical counterpart. The upper limit is set to
 | |
| 			the preset value, while the lower limit is set to 0. The
 | |
| 			counter freezes at count = preset when counting up, and
 | |
| 			at count = 0 when counting down. At either of these
 | |
| 			limits, the counting is resumed only when the count
 | |
| 			direction is reversed.
 | |
| 
 | |
| 		Non-recycle:
 | |
| 			Counter is disabled whenever a 24-bit count overflow or
 | |
| 			underflow takes place. The counter is re-enabled when a
 | |
| 			new count value is loaded to the counter via a preset
 | |
| 			operation or write to raw.
 | |
| 
 | |
| 		Modulo-N:
 | |
| 			A count boundary is set between 0 and the preset value.
 | |
| 			The counter is reset to 0 at count = preset when
 | |
| 			counting up, while the counter is set to the preset
 | |
| 			value at count = 0 when counting down; the counter does
 | |
| 			not freeze at the bundary points, but counts
 | |
| 			continuously throughout.
 | |
| 
 | |
| What:		/sys/bus/iio/devices/iio:deviceX/in_countY_noise_error
 | |
| KernelVersion:	4.10
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Read-only attribute that indicates whether excessive noise is
 | |
| 		present at the channel Y count inputs in quadrature clock mode;
 | |
| 		irrelevant in non-quadrature clock mode.
 | |
| 
 | |
| What:		/sys/bus/iio/devices/iio:deviceX/in_countY_preset
 | |
| KernelVersion:	4.10
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		If the counter device supports preset registers, the preset
 | |
| 		count for channel Y is provided by this attribute.
 | |
| 
 | |
| What:		/sys/bus/iio/devices/iio:deviceX/in_countY_quadrature_mode
 | |
| KernelVersion:	4.10
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Configure channel Y counter for non-quadrature or quadrature
 | |
| 		clock mode. Selecting non-quadrature clock mode will disable
 | |
| 		synchronous load mode. In quadrature clock mode, the channel Y
 | |
| 		scale attribute selects the encoder phase division (scale of 1
 | |
| 		selects full-cycle, scale of 0.5 selects half-cycle, scale of
 | |
| 		0.25 selects quarter-cycle) processed by the channel Y counter.
 | |
| 
 | |
| 		Non-quadrature:
 | |
| 			The filter and decoder circuit are bypassed. Encoder A
 | |
| 			input serves as the count input and B as the UP/DOWN
 | |
| 			direction control input, with B = 1 selecting UP Count
 | |
| 			mode and B = 0 selecting Down Count mode.
 | |
| 
 | |
| 		Quadrature:
 | |
| 			Encoder A and B inputs are digitally filtered and
 | |
| 			decoded for UP/DN clock.
 | |
| 
 | |
| What:		/sys/bus/iio/devices/iio:deviceX/in_countY_set_to_preset_on_index
 | |
| KernelVersion:	4.10
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Whether to set channel Y counter with channel Y preset value
 | |
| 		when channel Y index input is active, or continuously count.
 | |
| 		Valid attribute values are boolean.
 | |
| 
 | |
| What:		/sys/bus/iio/devices/iio:deviceX/in_indexY_index_polarity
 | |
| KernelVersion:	4.10
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Active level of channel Y index input; irrelevant in
 | |
| 		non-synchronous load mode.
 | |
| 
 | |
| What:		/sys/bus/iio/devices/iio:deviceX/in_indexY_synchronous_mode
 | |
| KernelVersion:	4.10
 | |
| Contact:	linux-iio@vger.kernel.org
 | |
| Description:
 | |
| 		Configure channel Y counter for non-synchronous or synchronous
 | |
| 		load mode. Synchronous load mode cannot be selected in
 | |
| 		non-quadrature clock mode.
 | |
| 
 | |
| 		Non-synchronous:
 | |
| 			A logic low level is the active level at this index
 | |
| 			input. The index function (as enabled via
 | |
| 			set_to_preset_on_index) is performed directly on the
 | |
| 			active level of the index input.
 | |
| 
 | |
| 		Synchronous:
 | |
| 			Intended for interfacing with encoder Index output in
 | |
| 			quadrature clock mode. The active level is configured
 | |
| 			via index_polarity. The index function (as enabled via
 | |
| 			set_to_preset_on_index) is performed synchronously with
 | |
| 			the quadrature clock on the active level of the index
 | |
| 			input.
 |