1639 lines
		
	
	
		
			46 KiB
		
	
	
	
		
			C
		
	
	
	
	
	
			
		
		
	
	
			1639 lines
		
	
	
		
			46 KiB
		
	
	
	
		
			C
		
	
	
	
	
	
| // SPDX-License-Identifier: GPL-2.0-only
 | |
| /*
 | |
|  *  Universal power supply monitor class
 | |
|  *
 | |
|  *  Copyright © 2007  Anton Vorontsov <cbou@mail.ru>
 | |
|  *  Copyright © 2004  Szabolcs Gyurko
 | |
|  *  Copyright © 2003  Ian Molton <spyro@f2s.com>
 | |
|  *
 | |
|  *  Modified: 2004, Oct     Szabolcs Gyurko
 | |
|  */
 | |
| 
 | |
| #include <linux/module.h>
 | |
| #include <linux/types.h>
 | |
| #include <linux/init.h>
 | |
| #include <linux/slab.h>
 | |
| #include <linux/delay.h>
 | |
| #include <linux/device.h>
 | |
| #include <linux/notifier.h>
 | |
| #include <linux/err.h>
 | |
| #include <linux/of.h>
 | |
| #include <linux/power_supply.h>
 | |
| #include <linux/property.h>
 | |
| #include <linux/thermal.h>
 | |
| #include <linux/fixp-arith.h>
 | |
| #include "power_supply.h"
 | |
| #include "samsung-sdi-battery.h"
 | |
| 
 | |
| /* exported for the APM Power driver, APM emulation */
 | |
| struct class *power_supply_class;
 | |
| EXPORT_SYMBOL_GPL(power_supply_class);
 | |
| 
 | |
| ATOMIC_NOTIFIER_HEAD(power_supply_notifier);
 | |
| EXPORT_SYMBOL_GPL(power_supply_notifier);
 | |
| 
 | |
| static struct device_type power_supply_dev_type;
 | |
| 
 | |
| #define POWER_SUPPLY_DEFERRED_REGISTER_TIME	msecs_to_jiffies(10)
 | |
| 
 | |
| static bool __power_supply_is_supplied_by(struct power_supply *supplier,
 | |
| 					 struct power_supply *supply)
 | |
| {
 | |
| 	int i;
 | |
| 
 | |
| 	if (!supply->supplied_from && !supplier->supplied_to)
 | |
| 		return false;
 | |
| 
 | |
| 	/* Support both supplied_to and supplied_from modes */
 | |
| 	if (supply->supplied_from) {
 | |
| 		if (!supplier->desc->name)
 | |
| 			return false;
 | |
| 		for (i = 0; i < supply->num_supplies; i++)
 | |
| 			if (!strcmp(supplier->desc->name, supply->supplied_from[i]))
 | |
| 				return true;
 | |
| 	} else {
 | |
| 		if (!supply->desc->name)
 | |
| 			return false;
 | |
| 		for (i = 0; i < supplier->num_supplicants; i++)
 | |
| 			if (!strcmp(supplier->supplied_to[i], supply->desc->name))
 | |
| 				return true;
 | |
| 	}
 | |
| 
 | |
| 	return false;
 | |
| }
 | |
| 
 | |
| static int __power_supply_changed_work(struct device *dev, void *data)
 | |
| {
 | |
| 	struct power_supply *psy = data;
 | |
| 	struct power_supply *pst = dev_get_drvdata(dev);
 | |
| 
 | |
| 	if (__power_supply_is_supplied_by(psy, pst)) {
 | |
| 		if (pst->desc->external_power_changed)
 | |
| 			pst->desc->external_power_changed(pst);
 | |
| 	}
 | |
| 
 | |
| 	return 0;
 | |
| }
 | |
| 
 | |
| static void power_supply_changed_work(struct work_struct *work)
 | |
| {
 | |
| 	unsigned long flags;
 | |
| 	struct power_supply *psy = container_of(work, struct power_supply,
 | |
| 						changed_work);
 | |
| 
 | |
| 	dev_dbg(&psy->dev, "%s\n", __func__);
 | |
| 
 | |
| 	spin_lock_irqsave(&psy->changed_lock, flags);
 | |
| 	/*
 | |
| 	 * Check 'changed' here to avoid issues due to race between
 | |
| 	 * power_supply_changed() and this routine. In worst case
 | |
| 	 * power_supply_changed() can be called again just before we take above
 | |
| 	 * lock. During the first call of this routine we will mark 'changed' as
 | |
| 	 * false and it will stay false for the next call as well.
 | |
| 	 */
 | |
| 	if (likely(psy->changed)) {
 | |
| 		psy->changed = false;
 | |
| 		spin_unlock_irqrestore(&psy->changed_lock, flags);
 | |
| 		class_for_each_device(power_supply_class, NULL, psy,
 | |
| 				      __power_supply_changed_work);
 | |
| 		power_supply_update_leds(psy);
 | |
| 		atomic_notifier_call_chain(&power_supply_notifier,
 | |
| 				PSY_EVENT_PROP_CHANGED, psy);
 | |
| 		kobject_uevent(&psy->dev.kobj, KOBJ_CHANGE);
 | |
| 		spin_lock_irqsave(&psy->changed_lock, flags);
 | |
| 	}
 | |
| 
 | |
| 	/*
 | |
| 	 * Hold the wakeup_source until all events are processed.
 | |
| 	 * power_supply_changed() might have called again and have set 'changed'
 | |
| 	 * to true.
 | |
| 	 */
 | |
| 	if (likely(!psy->changed))
 | |
| 		pm_relax(&psy->dev);
 | |
| 	spin_unlock_irqrestore(&psy->changed_lock, flags);
 | |
| }
 | |
| 
 | |
| void power_supply_changed(struct power_supply *psy)
 | |
| {
 | |
| 	unsigned long flags;
 | |
| 
 | |
| 	dev_dbg(&psy->dev, "%s\n", __func__);
 | |
| 
 | |
| 	spin_lock_irqsave(&psy->changed_lock, flags);
 | |
| 	psy->changed = true;
 | |
| 	pm_stay_awake(&psy->dev);
 | |
| 	spin_unlock_irqrestore(&psy->changed_lock, flags);
 | |
| 	schedule_work(&psy->changed_work);
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(power_supply_changed);
 | |
| 
 | |
| /*
 | |
|  * Notify that power supply was registered after parent finished the probing.
 | |
|  *
 | |
|  * Often power supply is registered from driver's probe function. However
 | |
|  * calling power_supply_changed() directly from power_supply_register()
 | |
|  * would lead to execution of get_property() function provided by the driver
 | |
|  * too early - before the probe ends.
 | |
|  *
 | |
|  * Avoid that by waiting on parent's mutex.
 | |
|  */
 | |
| static void power_supply_deferred_register_work(struct work_struct *work)
 | |
| {
 | |
| 	struct power_supply *psy = container_of(work, struct power_supply,
 | |
| 						deferred_register_work.work);
 | |
| 
 | |
| 	if (psy->dev.parent) {
 | |
| 		while (!mutex_trylock(&psy->dev.parent->mutex)) {
 | |
| 			if (psy->removing)
 | |
| 				return;
 | |
| 			msleep(10);
 | |
| 		}
 | |
| 	}
 | |
| 
 | |
| 	power_supply_changed(psy);
 | |
| 
 | |
| 	if (psy->dev.parent)
 | |
| 		mutex_unlock(&psy->dev.parent->mutex);
 | |
| }
 | |
| 
 | |
| #ifdef CONFIG_OF
 | |
| static int __power_supply_populate_supplied_from(struct device *dev,
 | |
| 						 void *data)
 | |
| {
 | |
| 	struct power_supply *psy = data;
 | |
| 	struct power_supply *epsy = dev_get_drvdata(dev);
 | |
| 	struct device_node *np;
 | |
| 	int i = 0;
 | |
| 
 | |
| 	do {
 | |
| 		np = of_parse_phandle(psy->of_node, "power-supplies", i++);
 | |
| 		if (!np)
 | |
| 			break;
 | |
| 
 | |
| 		if (np == epsy->of_node) {
 | |
| 			dev_dbg(&psy->dev, "%s: Found supply : %s\n",
 | |
| 				psy->desc->name, epsy->desc->name);
 | |
| 			psy->supplied_from[i-1] = (char *)epsy->desc->name;
 | |
| 			psy->num_supplies++;
 | |
| 			of_node_put(np);
 | |
| 			break;
 | |
| 		}
 | |
| 		of_node_put(np);
 | |
| 	} while (np);
 | |
| 
 | |
| 	return 0;
 | |
| }
 | |
| 
 | |
| static int power_supply_populate_supplied_from(struct power_supply *psy)
 | |
| {
 | |
| 	int error;
 | |
| 
 | |
| 	error = class_for_each_device(power_supply_class, NULL, psy,
 | |
| 				      __power_supply_populate_supplied_from);
 | |
| 
 | |
| 	dev_dbg(&psy->dev, "%s %d\n", __func__, error);
 | |
| 
 | |
| 	return error;
 | |
| }
 | |
| 
 | |
| static int  __power_supply_find_supply_from_node(struct device *dev,
 | |
| 						 void *data)
 | |
| {
 | |
| 	struct device_node *np = data;
 | |
| 	struct power_supply *epsy = dev_get_drvdata(dev);
 | |
| 
 | |
| 	/* returning non-zero breaks out of class_for_each_device loop */
 | |
| 	if (epsy->of_node == np)
 | |
| 		return 1;
 | |
| 
 | |
| 	return 0;
 | |
| }
 | |
| 
 | |
| static int power_supply_find_supply_from_node(struct device_node *supply_node)
 | |
| {
 | |
| 	int error;
 | |
| 
 | |
| 	/*
 | |
| 	 * class_for_each_device() either returns its own errors or values
 | |
| 	 * returned by __power_supply_find_supply_from_node().
 | |
| 	 *
 | |
| 	 * __power_supply_find_supply_from_node() will return 0 (no match)
 | |
| 	 * or 1 (match).
 | |
| 	 *
 | |
| 	 * We return 0 if class_for_each_device() returned 1, -EPROBE_DEFER if
 | |
| 	 * it returned 0, or error as returned by it.
 | |
| 	 */
 | |
| 	error = class_for_each_device(power_supply_class, NULL, supply_node,
 | |
| 				       __power_supply_find_supply_from_node);
 | |
| 
 | |
| 	return error ? (error == 1 ? 0 : error) : -EPROBE_DEFER;
 | |
| }
 | |
| 
 | |
| static int power_supply_check_supplies(struct power_supply *psy)
 | |
| {
 | |
| 	struct device_node *np;
 | |
| 	int cnt = 0;
 | |
| 
 | |
| 	/* If there is already a list honor it */
 | |
| 	if (psy->supplied_from && psy->num_supplies > 0)
 | |
| 		return 0;
 | |
| 
 | |
| 	/* No device node found, nothing to do */
 | |
| 	if (!psy->of_node)
 | |
| 		return 0;
 | |
| 
 | |
| 	do {
 | |
| 		int ret;
 | |
| 
 | |
| 		np = of_parse_phandle(psy->of_node, "power-supplies", cnt++);
 | |
| 		if (!np)
 | |
| 			break;
 | |
| 
 | |
| 		ret = power_supply_find_supply_from_node(np);
 | |
| 		of_node_put(np);
 | |
| 
 | |
| 		if (ret) {
 | |
| 			dev_dbg(&psy->dev, "Failed to find supply!\n");
 | |
| 			return ret;
 | |
| 		}
 | |
| 	} while (np);
 | |
| 
 | |
| 	/* Missing valid "power-supplies" entries */
 | |
| 	if (cnt == 1)
 | |
| 		return 0;
 | |
| 
 | |
| 	/* All supplies found, allocate char ** array for filling */
 | |
| 	psy->supplied_from = devm_kzalloc(&psy->dev, sizeof(*psy->supplied_from),
 | |
| 					  GFP_KERNEL);
 | |
| 	if (!psy->supplied_from)
 | |
| 		return -ENOMEM;
 | |
| 
 | |
| 	*psy->supplied_from = devm_kcalloc(&psy->dev,
 | |
| 					   cnt - 1, sizeof(**psy->supplied_from),
 | |
| 					   GFP_KERNEL);
 | |
| 	if (!*psy->supplied_from)
 | |
| 		return -ENOMEM;
 | |
| 
 | |
| 	return power_supply_populate_supplied_from(psy);
 | |
| }
 | |
| #else
 | |
| static int power_supply_check_supplies(struct power_supply *psy)
 | |
| {
 | |
| 	int nval, ret;
 | |
| 
 | |
| 	if (!psy->dev.parent)
 | |
| 		return 0;
 | |
| 
 | |
| 	nval = device_property_string_array_count(psy->dev.parent, "supplied-from");
 | |
| 	if (nval <= 0)
 | |
| 		return 0;
 | |
| 
 | |
| 	psy->supplied_from = devm_kmalloc_array(&psy->dev, nval,
 | |
| 						sizeof(char *), GFP_KERNEL);
 | |
| 	if (!psy->supplied_from)
 | |
| 		return -ENOMEM;
 | |
| 
 | |
| 	ret = device_property_read_string_array(psy->dev.parent,
 | |
| 		"supplied-from", (const char **)psy->supplied_from, nval);
 | |
| 	if (ret < 0)
 | |
| 		return ret;
 | |
| 
 | |
| 	psy->num_supplies = nval;
 | |
| 
 | |
| 	return 0;
 | |
| }
 | |
| #endif
 | |
| 
 | |
| struct psy_am_i_supplied_data {
 | |
| 	struct power_supply *psy;
 | |
| 	unsigned int count;
 | |
| };
 | |
| 
 | |
| static int __power_supply_am_i_supplied(struct device *dev, void *_data)
 | |
| {
 | |
| 	union power_supply_propval ret = {0,};
 | |
| 	struct power_supply *epsy = dev_get_drvdata(dev);
 | |
| 	struct psy_am_i_supplied_data *data = _data;
 | |
| 
 | |
| 	if (__power_supply_is_supplied_by(epsy, data->psy)) {
 | |
| 		data->count++;
 | |
| 		if (!epsy->desc->get_property(epsy, POWER_SUPPLY_PROP_ONLINE,
 | |
| 					&ret))
 | |
| 			return ret.intval;
 | |
| 	}
 | |
| 
 | |
| 	return 0;
 | |
| }
 | |
| 
 | |
| int power_supply_am_i_supplied(struct power_supply *psy)
 | |
| {
 | |
| 	struct psy_am_i_supplied_data data = { psy, 0 };
 | |
| 	int error;
 | |
| 
 | |
| 	error = class_for_each_device(power_supply_class, NULL, &data,
 | |
| 				      __power_supply_am_i_supplied);
 | |
| 
 | |
| 	dev_dbg(&psy->dev, "%s count %u err %d\n", __func__, data.count, error);
 | |
| 
 | |
| 	if (data.count == 0)
 | |
| 		return -ENODEV;
 | |
| 
 | |
| 	return error;
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(power_supply_am_i_supplied);
 | |
| 
 | |
| static int __power_supply_is_system_supplied(struct device *dev, void *data)
 | |
| {
 | |
| 	union power_supply_propval ret = {0,};
 | |
| 	struct power_supply *psy = dev_get_drvdata(dev);
 | |
| 	unsigned int *count = data;
 | |
| 
 | |
| 	if (!psy->desc->get_property(psy, POWER_SUPPLY_PROP_SCOPE, &ret))
 | |
| 		if (ret.intval == POWER_SUPPLY_SCOPE_DEVICE)
 | |
| 			return 0;
 | |
| 
 | |
| 	(*count)++;
 | |
| 	if (psy->desc->type != POWER_SUPPLY_TYPE_BATTERY)
 | |
| 		if (!psy->desc->get_property(psy, POWER_SUPPLY_PROP_ONLINE,
 | |
| 					&ret))
 | |
| 			return ret.intval;
 | |
| 
 | |
| 	return 0;
 | |
| }
 | |
| 
 | |
| int power_supply_is_system_supplied(void)
 | |
| {
 | |
| 	int error;
 | |
| 	unsigned int count = 0;
 | |
| 
 | |
| 	error = class_for_each_device(power_supply_class, NULL, &count,
 | |
| 				      __power_supply_is_system_supplied);
 | |
| 
 | |
| 	/*
 | |
| 	 * If no system scope power class device was found at all, most probably we
 | |
| 	 * are running on a desktop system, so assume we are on mains power.
 | |
| 	 */
 | |
| 	if (count == 0)
 | |
| 		return 1;
 | |
| 
 | |
| 	return error;
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(power_supply_is_system_supplied);
 | |
| 
 | |
| struct psy_get_supplier_prop_data {
 | |
| 	struct power_supply *psy;
 | |
| 	enum power_supply_property psp;
 | |
| 	union power_supply_propval *val;
 | |
| };
 | |
| 
 | |
| static int __power_supply_get_supplier_property(struct device *dev, void *_data)
 | |
| {
 | |
| 	struct power_supply *epsy = dev_get_drvdata(dev);
 | |
| 	struct psy_get_supplier_prop_data *data = _data;
 | |
| 
 | |
| 	if (__power_supply_is_supplied_by(epsy, data->psy))
 | |
| 		if (!power_supply_get_property(epsy, data->psp, data->val))
 | |
| 			return 1; /* Success */
 | |
| 
 | |
| 	return 0; /* Continue iterating */
 | |
| }
 | |
| 
 | |
| int power_supply_get_property_from_supplier(struct power_supply *psy,
 | |
| 					    enum power_supply_property psp,
 | |
| 					    union power_supply_propval *val)
 | |
| {
 | |
| 	struct psy_get_supplier_prop_data data = {
 | |
| 		.psy = psy,
 | |
| 		.psp = psp,
 | |
| 		.val = val,
 | |
| 	};
 | |
| 	int ret;
 | |
| 
 | |
| 	/*
 | |
| 	 * This function is not intended for use with a supply with multiple
 | |
| 	 * suppliers, we simply pick the first supply to report the psp.
 | |
| 	 */
 | |
| 	ret = class_for_each_device(power_supply_class, NULL, &data,
 | |
| 				    __power_supply_get_supplier_property);
 | |
| 	if (ret < 0)
 | |
| 		return ret;
 | |
| 	if (ret == 0)
 | |
| 		return -ENODEV;
 | |
| 
 | |
| 	return 0;
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(power_supply_get_property_from_supplier);
 | |
| 
 | |
| int power_supply_set_battery_charged(struct power_supply *psy)
 | |
| {
 | |
| 	if (atomic_read(&psy->use_cnt) >= 0 &&
 | |
| 			psy->desc->type == POWER_SUPPLY_TYPE_BATTERY &&
 | |
| 			psy->desc->set_charged) {
 | |
| 		psy->desc->set_charged(psy);
 | |
| 		return 0;
 | |
| 	}
 | |
| 
 | |
| 	return -EINVAL;
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(power_supply_set_battery_charged);
 | |
| 
 | |
| static int power_supply_match_device_by_name(struct device *dev, const void *data)
 | |
| {
 | |
| 	const char *name = data;
 | |
| 	struct power_supply *psy = dev_get_drvdata(dev);
 | |
| 
 | |
| 	return strcmp(psy->desc->name, name) == 0;
 | |
| }
 | |
| 
 | |
| /**
 | |
|  * power_supply_get_by_name() - Search for a power supply and returns its ref
 | |
|  * @name: Power supply name to fetch
 | |
|  *
 | |
|  * If power supply was found, it increases reference count for the
 | |
|  * internal power supply's device. The user should power_supply_put()
 | |
|  * after usage.
 | |
|  *
 | |
|  * Return: On success returns a reference to a power supply with
 | |
|  * matching name equals to @name, a NULL otherwise.
 | |
|  */
 | |
| struct power_supply *power_supply_get_by_name(const char *name)
 | |
| {
 | |
| 	struct power_supply *psy = NULL;
 | |
| 	struct device *dev = class_find_device(power_supply_class, NULL, name,
 | |
| 					power_supply_match_device_by_name);
 | |
| 
 | |
| 	if (dev) {
 | |
| 		psy = dev_get_drvdata(dev);
 | |
| 		atomic_inc(&psy->use_cnt);
 | |
| 	}
 | |
| 
 | |
| 	return psy;
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(power_supply_get_by_name);
 | |
| 
 | |
| /**
 | |
|  * power_supply_put() - Drop reference obtained with power_supply_get_by_name
 | |
|  * @psy: Reference to put
 | |
|  *
 | |
|  * The reference to power supply should be put before unregistering
 | |
|  * the power supply.
 | |
|  */
 | |
| void power_supply_put(struct power_supply *psy)
 | |
| {
 | |
| 	might_sleep();
 | |
| 
 | |
| 	atomic_dec(&psy->use_cnt);
 | |
| 	put_device(&psy->dev);
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(power_supply_put);
 | |
| 
 | |
| #ifdef CONFIG_OF
 | |
| static int power_supply_match_device_node(struct device *dev, const void *data)
 | |
| {
 | |
| 	return dev->parent && dev->parent->of_node == data;
 | |
| }
 | |
| 
 | |
| /**
 | |
|  * power_supply_get_by_phandle() - Search for a power supply and returns its ref
 | |
|  * @np: Pointer to device node holding phandle property
 | |
|  * @property: Name of property holding a power supply name
 | |
|  *
 | |
|  * If power supply was found, it increases reference count for the
 | |
|  * internal power supply's device. The user should power_supply_put()
 | |
|  * after usage.
 | |
|  *
 | |
|  * Return: On success returns a reference to a power supply with
 | |
|  * matching name equals to value under @property, NULL or ERR_PTR otherwise.
 | |
|  */
 | |
| struct power_supply *power_supply_get_by_phandle(struct device_node *np,
 | |
| 							const char *property)
 | |
| {
 | |
| 	struct device_node *power_supply_np;
 | |
| 	struct power_supply *psy = NULL;
 | |
| 	struct device *dev;
 | |
| 
 | |
| 	power_supply_np = of_parse_phandle(np, property, 0);
 | |
| 	if (!power_supply_np)
 | |
| 		return ERR_PTR(-ENODEV);
 | |
| 
 | |
| 	dev = class_find_device(power_supply_class, NULL, power_supply_np,
 | |
| 						power_supply_match_device_node);
 | |
| 
 | |
| 	of_node_put(power_supply_np);
 | |
| 
 | |
| 	if (dev) {
 | |
| 		psy = dev_get_drvdata(dev);
 | |
| 		atomic_inc(&psy->use_cnt);
 | |
| 	}
 | |
| 
 | |
| 	return psy;
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(power_supply_get_by_phandle);
 | |
| 
 | |
| static void devm_power_supply_put(struct device *dev, void *res)
 | |
| {
 | |
| 	struct power_supply **psy = res;
 | |
| 
 | |
| 	power_supply_put(*psy);
 | |
| }
 | |
| 
 | |
| /**
 | |
|  * devm_power_supply_get_by_phandle() - Resource managed version of
 | |
|  *  power_supply_get_by_phandle()
 | |
|  * @dev: Pointer to device holding phandle property
 | |
|  * @property: Name of property holding a power supply phandle
 | |
|  *
 | |
|  * Return: On success returns a reference to a power supply with
 | |
|  * matching name equals to value under @property, NULL or ERR_PTR otherwise.
 | |
|  */
 | |
| struct power_supply *devm_power_supply_get_by_phandle(struct device *dev,
 | |
| 						      const char *property)
 | |
| {
 | |
| 	struct power_supply **ptr, *psy;
 | |
| 
 | |
| 	if (!dev->of_node)
 | |
| 		return ERR_PTR(-ENODEV);
 | |
| 
 | |
| 	ptr = devres_alloc(devm_power_supply_put, sizeof(*ptr), GFP_KERNEL);
 | |
| 	if (!ptr)
 | |
| 		return ERR_PTR(-ENOMEM);
 | |
| 
 | |
| 	psy = power_supply_get_by_phandle(dev->of_node, property);
 | |
| 	if (IS_ERR_OR_NULL(psy)) {
 | |
| 		devres_free(ptr);
 | |
| 	} else {
 | |
| 		*ptr = psy;
 | |
| 		devres_add(dev, ptr);
 | |
| 	}
 | |
| 	return psy;
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(devm_power_supply_get_by_phandle);
 | |
| #endif /* CONFIG_OF */
 | |
| 
 | |
| int power_supply_get_battery_info(struct power_supply *psy,
 | |
| 				  struct power_supply_battery_info **info_out)
 | |
| {
 | |
| 	struct power_supply_resistance_temp_table *resist_table;
 | |
| 	struct power_supply_battery_info *info;
 | |
| 	struct device_node *battery_np = NULL;
 | |
| 	struct fwnode_reference_args args;
 | |
| 	struct fwnode_handle *fwnode = NULL;
 | |
| 	const char *value;
 | |
| 	int err, len, index;
 | |
| 	const __be32 *list;
 | |
| 	u32 min_max[2];
 | |
| 
 | |
| 	if (psy->of_node) {
 | |
| 		battery_np = of_parse_phandle(psy->of_node, "monitored-battery", 0);
 | |
| 		if (!battery_np)
 | |
| 			return -ENODEV;
 | |
| 
 | |
| 		fwnode = fwnode_handle_get(of_fwnode_handle(battery_np));
 | |
| 	} else if (psy->dev.parent) {
 | |
| 		err = fwnode_property_get_reference_args(
 | |
| 					dev_fwnode(psy->dev.parent),
 | |
| 					"monitored-battery", NULL, 0, 0, &args);
 | |
| 		if (err)
 | |
| 			return err;
 | |
| 
 | |
| 		fwnode = args.fwnode;
 | |
| 	}
 | |
| 
 | |
| 	if (!fwnode)
 | |
| 		return -ENOENT;
 | |
| 
 | |
| 	err = fwnode_property_read_string(fwnode, "compatible", &value);
 | |
| 	if (err)
 | |
| 		goto out_put_node;
 | |
| 
 | |
| 
 | |
| 	/* Try static batteries first */
 | |
| 	err = samsung_sdi_battery_get_info(&psy->dev, value, &info);
 | |
| 	if (!err)
 | |
| 		goto out_ret_pointer;
 | |
| 	else if (err == -ENODEV)
 | |
| 		/*
 | |
| 		 * Device does not have a static battery.
 | |
| 		 * Proceed to look for a simple battery.
 | |
| 		 */
 | |
| 		err = 0;
 | |
| 
 | |
| 	if (strcmp("simple-battery", value)) {
 | |
| 		err = -ENODEV;
 | |
| 		goto out_put_node;
 | |
| 	}
 | |
| 
 | |
| 	info = devm_kzalloc(&psy->dev, sizeof(*info), GFP_KERNEL);
 | |
| 	if (!info) {
 | |
| 		err = -ENOMEM;
 | |
| 		goto out_put_node;
 | |
| 	}
 | |
| 
 | |
| 	info->technology                     = POWER_SUPPLY_TECHNOLOGY_UNKNOWN;
 | |
| 	info->energy_full_design_uwh         = -EINVAL;
 | |
| 	info->charge_full_design_uah         = -EINVAL;
 | |
| 	info->voltage_min_design_uv          = -EINVAL;
 | |
| 	info->voltage_max_design_uv          = -EINVAL;
 | |
| 	info->precharge_current_ua           = -EINVAL;
 | |
| 	info->charge_term_current_ua         = -EINVAL;
 | |
| 	info->constant_charge_current_max_ua = -EINVAL;
 | |
| 	info->constant_charge_voltage_max_uv = -EINVAL;
 | |
| 	info->tricklecharge_current_ua       = -EINVAL;
 | |
| 	info->precharge_voltage_max_uv       = -EINVAL;
 | |
| 	info->charge_restart_voltage_uv      = -EINVAL;
 | |
| 	info->overvoltage_limit_uv           = -EINVAL;
 | |
| 	info->maintenance_charge             = NULL;
 | |
| 	info->alert_low_temp_charge_current_ua = -EINVAL;
 | |
| 	info->alert_low_temp_charge_voltage_uv = -EINVAL;
 | |
| 	info->alert_high_temp_charge_current_ua = -EINVAL;
 | |
| 	info->alert_high_temp_charge_voltage_uv = -EINVAL;
 | |
| 	info->temp_ambient_alert_min         = INT_MIN;
 | |
| 	info->temp_ambient_alert_max         = INT_MAX;
 | |
| 	info->temp_alert_min                 = INT_MIN;
 | |
| 	info->temp_alert_max                 = INT_MAX;
 | |
| 	info->temp_min                       = INT_MIN;
 | |
| 	info->temp_max                       = INT_MAX;
 | |
| 	info->factory_internal_resistance_uohm  = -EINVAL;
 | |
| 	info->resist_table                   = NULL;
 | |
| 	info->bti_resistance_ohm             = -EINVAL;
 | |
| 	info->bti_resistance_tolerance       = -EINVAL;
 | |
| 
 | |
| 	for (index = 0; index < POWER_SUPPLY_OCV_TEMP_MAX; index++) {
 | |
| 		info->ocv_table[index]       = NULL;
 | |
| 		info->ocv_temp[index]        = -EINVAL;
 | |
| 		info->ocv_table_size[index]  = -EINVAL;
 | |
| 	}
 | |
| 
 | |
| 	/* The property and field names below must correspond to elements
 | |
| 	 * in enum power_supply_property. For reasoning, see
 | |
| 	 * Documentation/power/power_supply_class.rst.
 | |
| 	 */
 | |
| 
 | |
| 	if (!fwnode_property_read_string(fwnode, "device-chemistry", &value)) {
 | |
| 		if (!strcmp("nickel-cadmium", value))
 | |
| 			info->technology = POWER_SUPPLY_TECHNOLOGY_NiCd;
 | |
| 		else if (!strcmp("nickel-metal-hydride", value))
 | |
| 			info->technology = POWER_SUPPLY_TECHNOLOGY_NiMH;
 | |
| 		else if (!strcmp("lithium-ion", value))
 | |
| 			/* Imprecise lithium-ion type */
 | |
| 			info->technology = POWER_SUPPLY_TECHNOLOGY_LION;
 | |
| 		else if (!strcmp("lithium-ion-polymer", value))
 | |
| 			info->technology = POWER_SUPPLY_TECHNOLOGY_LIPO;
 | |
| 		else if (!strcmp("lithium-ion-iron-phosphate", value))
 | |
| 			info->technology = POWER_SUPPLY_TECHNOLOGY_LiFe;
 | |
| 		else if (!strcmp("lithium-ion-manganese-oxide", value))
 | |
| 			info->technology = POWER_SUPPLY_TECHNOLOGY_LiMn;
 | |
| 		else
 | |
| 			dev_warn(&psy->dev, "%s unknown battery type\n", value);
 | |
| 	}
 | |
| 
 | |
| 	fwnode_property_read_u32(fwnode, "energy-full-design-microwatt-hours",
 | |
| 			     &info->energy_full_design_uwh);
 | |
| 	fwnode_property_read_u32(fwnode, "charge-full-design-microamp-hours",
 | |
| 			     &info->charge_full_design_uah);
 | |
| 	fwnode_property_read_u32(fwnode, "voltage-min-design-microvolt",
 | |
| 			     &info->voltage_min_design_uv);
 | |
| 	fwnode_property_read_u32(fwnode, "voltage-max-design-microvolt",
 | |
| 			     &info->voltage_max_design_uv);
 | |
| 	fwnode_property_read_u32(fwnode, "trickle-charge-current-microamp",
 | |
| 			     &info->tricklecharge_current_ua);
 | |
| 	fwnode_property_read_u32(fwnode, "precharge-current-microamp",
 | |
| 			     &info->precharge_current_ua);
 | |
| 	fwnode_property_read_u32(fwnode, "precharge-upper-limit-microvolt",
 | |
| 			     &info->precharge_voltage_max_uv);
 | |
| 	fwnode_property_read_u32(fwnode, "charge-term-current-microamp",
 | |
| 			     &info->charge_term_current_ua);
 | |
| 	fwnode_property_read_u32(fwnode, "re-charge-voltage-microvolt",
 | |
| 			     &info->charge_restart_voltage_uv);
 | |
| 	fwnode_property_read_u32(fwnode, "over-voltage-threshold-microvolt",
 | |
| 			     &info->overvoltage_limit_uv);
 | |
| 	fwnode_property_read_u32(fwnode, "constant-charge-current-max-microamp",
 | |
| 			     &info->constant_charge_current_max_ua);
 | |
| 	fwnode_property_read_u32(fwnode, "constant-charge-voltage-max-microvolt",
 | |
| 			     &info->constant_charge_voltage_max_uv);
 | |
| 	fwnode_property_read_u32(fwnode, "factory-internal-resistance-micro-ohms",
 | |
| 			     &info->factory_internal_resistance_uohm);
 | |
| 
 | |
| 	if (!fwnode_property_read_u32_array(fwnode, "ambient-celsius",
 | |
| 					    min_max, ARRAY_SIZE(min_max))) {
 | |
| 		info->temp_ambient_alert_min = min_max[0];
 | |
| 		info->temp_ambient_alert_max = min_max[1];
 | |
| 	}
 | |
| 	if (!fwnode_property_read_u32_array(fwnode, "alert-celsius",
 | |
| 					    min_max, ARRAY_SIZE(min_max))) {
 | |
| 		info->temp_alert_min = min_max[0];
 | |
| 		info->temp_alert_max = min_max[1];
 | |
| 	}
 | |
| 	if (!fwnode_property_read_u32_array(fwnode, "operating-range-celsius",
 | |
| 					    min_max, ARRAY_SIZE(min_max))) {
 | |
| 		info->temp_min = min_max[0];
 | |
| 		info->temp_max = min_max[1];
 | |
| 	}
 | |
| 
 | |
| 	/*
 | |
| 	 * The below code uses raw of-data parsing to parse
 | |
| 	 * /schemas/types.yaml#/definitions/uint32-matrix
 | |
| 	 * data, so for now this is only support with of.
 | |
| 	 */
 | |
| 	if (!battery_np)
 | |
| 		goto out_ret_pointer;
 | |
| 
 | |
| 	len = of_property_count_u32_elems(battery_np, "ocv-capacity-celsius");
 | |
| 	if (len < 0 && len != -EINVAL) {
 | |
| 		err = len;
 | |
| 		goto out_put_node;
 | |
| 	} else if (len > POWER_SUPPLY_OCV_TEMP_MAX) {
 | |
| 		dev_err(&psy->dev, "Too many temperature values\n");
 | |
| 		err = -EINVAL;
 | |
| 		goto out_put_node;
 | |
| 	} else if (len > 0) {
 | |
| 		of_property_read_u32_array(battery_np, "ocv-capacity-celsius",
 | |
| 					   info->ocv_temp, len);
 | |
| 	}
 | |
| 
 | |
| 	for (index = 0; index < len; index++) {
 | |
| 		struct power_supply_battery_ocv_table *table;
 | |
| 		char *propname;
 | |
| 		int i, tab_len, size;
 | |
| 
 | |
| 		propname = kasprintf(GFP_KERNEL, "ocv-capacity-table-%d", index);
 | |
| 		if (!propname) {
 | |
| 			power_supply_put_battery_info(psy, info);
 | |
| 			err = -ENOMEM;
 | |
| 			goto out_put_node;
 | |
| 		}
 | |
| 		list = of_get_property(battery_np, propname, &size);
 | |
| 		if (!list || !size) {
 | |
| 			dev_err(&psy->dev, "failed to get %s\n", propname);
 | |
| 			kfree(propname);
 | |
| 			power_supply_put_battery_info(psy, info);
 | |
| 			err = -EINVAL;
 | |
| 			goto out_put_node;
 | |
| 		}
 | |
| 
 | |
| 		kfree(propname);
 | |
| 		tab_len = size / (2 * sizeof(__be32));
 | |
| 		info->ocv_table_size[index] = tab_len;
 | |
| 
 | |
| 		table = info->ocv_table[index] =
 | |
| 			devm_kcalloc(&psy->dev, tab_len, sizeof(*table), GFP_KERNEL);
 | |
| 		if (!info->ocv_table[index]) {
 | |
| 			power_supply_put_battery_info(psy, info);
 | |
| 			err = -ENOMEM;
 | |
| 			goto out_put_node;
 | |
| 		}
 | |
| 
 | |
| 		for (i = 0; i < tab_len; i++) {
 | |
| 			table[i].ocv = be32_to_cpu(*list);
 | |
| 			list++;
 | |
| 			table[i].capacity = be32_to_cpu(*list);
 | |
| 			list++;
 | |
| 		}
 | |
| 	}
 | |
| 
 | |
| 	list = of_get_property(battery_np, "resistance-temp-table", &len);
 | |
| 	if (!list || !len)
 | |
| 		goto out_ret_pointer;
 | |
| 
 | |
| 	info->resist_table_size = len / (2 * sizeof(__be32));
 | |
| 	resist_table = info->resist_table = devm_kcalloc(&psy->dev,
 | |
| 							 info->resist_table_size,
 | |
| 							 sizeof(*resist_table),
 | |
| 							 GFP_KERNEL);
 | |
| 	if (!info->resist_table) {
 | |
| 		power_supply_put_battery_info(psy, info);
 | |
| 		err = -ENOMEM;
 | |
| 		goto out_put_node;
 | |
| 	}
 | |
| 
 | |
| 	for (index = 0; index < info->resist_table_size; index++) {
 | |
| 		resist_table[index].temp = be32_to_cpu(*list++);
 | |
| 		resist_table[index].resistance = be32_to_cpu(*list++);
 | |
| 	}
 | |
| 
 | |
| out_ret_pointer:
 | |
| 	/* Finally return the whole thing */
 | |
| 	*info_out = info;
 | |
| 
 | |
| out_put_node:
 | |
| 	fwnode_handle_put(fwnode);
 | |
| 	of_node_put(battery_np);
 | |
| 	return err;
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(power_supply_get_battery_info);
 | |
| 
 | |
| void power_supply_put_battery_info(struct power_supply *psy,
 | |
| 				   struct power_supply_battery_info *info)
 | |
| {
 | |
| 	int i;
 | |
| 
 | |
| 	for (i = 0; i < POWER_SUPPLY_OCV_TEMP_MAX; i++) {
 | |
| 		if (info->ocv_table[i])
 | |
| 			devm_kfree(&psy->dev, info->ocv_table[i]);
 | |
| 	}
 | |
| 
 | |
| 	if (info->resist_table)
 | |
| 		devm_kfree(&psy->dev, info->resist_table);
 | |
| 
 | |
| 	devm_kfree(&psy->dev, info);
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(power_supply_put_battery_info);
 | |
| 
 | |
| const enum power_supply_property power_supply_battery_info_properties[] = {
 | |
| 	POWER_SUPPLY_PROP_TECHNOLOGY,
 | |
| 	POWER_SUPPLY_PROP_ENERGY_FULL_DESIGN,
 | |
| 	POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN,
 | |
| 	POWER_SUPPLY_PROP_VOLTAGE_MIN_DESIGN,
 | |
| 	POWER_SUPPLY_PROP_VOLTAGE_MAX_DESIGN,
 | |
| 	POWER_SUPPLY_PROP_PRECHARGE_CURRENT,
 | |
| 	POWER_SUPPLY_PROP_CHARGE_TERM_CURRENT,
 | |
| 	POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT_MAX,
 | |
| 	POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE_MAX,
 | |
| 	POWER_SUPPLY_PROP_TEMP_AMBIENT_ALERT_MIN,
 | |
| 	POWER_SUPPLY_PROP_TEMP_AMBIENT_ALERT_MAX,
 | |
| 	POWER_SUPPLY_PROP_TEMP_ALERT_MIN,
 | |
| 	POWER_SUPPLY_PROP_TEMP_ALERT_MAX,
 | |
| 	POWER_SUPPLY_PROP_TEMP_MIN,
 | |
| 	POWER_SUPPLY_PROP_TEMP_MAX,
 | |
| };
 | |
| EXPORT_SYMBOL_GPL(power_supply_battery_info_properties);
 | |
| 
 | |
| const size_t power_supply_battery_info_properties_size = ARRAY_SIZE(power_supply_battery_info_properties);
 | |
| EXPORT_SYMBOL_GPL(power_supply_battery_info_properties_size);
 | |
| 
 | |
| bool power_supply_battery_info_has_prop(struct power_supply_battery_info *info,
 | |
| 				        enum power_supply_property psp)
 | |
| {
 | |
| 	if (!info)
 | |
| 		return false;
 | |
| 
 | |
| 	switch (psp) {
 | |
| 		case POWER_SUPPLY_PROP_TECHNOLOGY:
 | |
| 			return info->technology != POWER_SUPPLY_TECHNOLOGY_UNKNOWN;
 | |
| 		case POWER_SUPPLY_PROP_ENERGY_FULL_DESIGN:
 | |
| 			return info->energy_full_design_uwh >= 0;
 | |
| 		case POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN:
 | |
| 			return info->charge_full_design_uah >= 0;
 | |
| 		case POWER_SUPPLY_PROP_VOLTAGE_MIN_DESIGN:
 | |
| 			return info->voltage_min_design_uv >= 0;
 | |
| 		case POWER_SUPPLY_PROP_VOLTAGE_MAX_DESIGN:
 | |
| 			return info->voltage_max_design_uv >= 0;
 | |
| 		case POWER_SUPPLY_PROP_PRECHARGE_CURRENT:
 | |
| 			return info->precharge_current_ua >= 0;
 | |
| 		case POWER_SUPPLY_PROP_CHARGE_TERM_CURRENT:
 | |
| 			return info->charge_term_current_ua >= 0;
 | |
| 		case POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT_MAX:
 | |
| 			return info->constant_charge_current_max_ua >= 0;
 | |
| 		case POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE_MAX:
 | |
| 			return info->constant_charge_voltage_max_uv >= 0;
 | |
| 		case POWER_SUPPLY_PROP_TEMP_AMBIENT_ALERT_MIN:
 | |
| 			return info->temp_ambient_alert_min > INT_MIN;
 | |
| 		case POWER_SUPPLY_PROP_TEMP_AMBIENT_ALERT_MAX:
 | |
| 			return info->temp_ambient_alert_max < INT_MAX;
 | |
| 		case POWER_SUPPLY_PROP_TEMP_ALERT_MIN:
 | |
| 			return info->temp_alert_min > INT_MIN;
 | |
| 		case POWER_SUPPLY_PROP_TEMP_ALERT_MAX:
 | |
| 			return info->temp_alert_max < INT_MAX;
 | |
| 		case POWER_SUPPLY_PROP_TEMP_MIN:
 | |
| 			return info->temp_min > INT_MIN;
 | |
| 		case POWER_SUPPLY_PROP_TEMP_MAX:
 | |
| 			return info->temp_max < INT_MAX;
 | |
| 		default:
 | |
| 			return false;
 | |
| 	}
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(power_supply_battery_info_has_prop);
 | |
| 
 | |
| int power_supply_battery_info_get_prop(struct power_supply_battery_info *info,
 | |
| 				       enum power_supply_property psp,
 | |
| 				       union power_supply_propval *val)
 | |
| {
 | |
| 	if (!info)
 | |
| 		return -EINVAL;
 | |
| 
 | |
| 	if (!power_supply_battery_info_has_prop(info, psp))
 | |
| 		return -EINVAL;
 | |
| 
 | |
| 	switch (psp) {
 | |
| 		case POWER_SUPPLY_PROP_TECHNOLOGY:
 | |
| 			val->intval = info->technology;
 | |
| 			return 0;
 | |
| 		case POWER_SUPPLY_PROP_ENERGY_FULL_DESIGN:
 | |
| 			val->intval = info->energy_full_design_uwh;
 | |
| 			return 0;
 | |
| 		case POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN:
 | |
| 			val->intval = info->charge_full_design_uah;
 | |
| 			return 0;
 | |
| 		case POWER_SUPPLY_PROP_VOLTAGE_MIN_DESIGN:
 | |
| 			val->intval = info->voltage_min_design_uv;
 | |
| 			return 0;
 | |
| 		case POWER_SUPPLY_PROP_VOLTAGE_MAX_DESIGN:
 | |
| 			val->intval = info->voltage_max_design_uv;
 | |
| 			return 0;
 | |
| 		case POWER_SUPPLY_PROP_PRECHARGE_CURRENT:
 | |
| 			val->intval = info->precharge_current_ua;
 | |
| 			return 0;
 | |
| 		case POWER_SUPPLY_PROP_CHARGE_TERM_CURRENT:
 | |
| 			val->intval = info->charge_term_current_ua;
 | |
| 			return 0;
 | |
| 		case POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT_MAX:
 | |
| 			val->intval = info->constant_charge_current_max_ua;
 | |
| 			return 0;
 | |
| 		case POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE_MAX:
 | |
| 			val->intval = info->constant_charge_voltage_max_uv;
 | |
| 			return 0;
 | |
| 		case POWER_SUPPLY_PROP_TEMP_AMBIENT_ALERT_MIN:
 | |
| 			val->intval = info->temp_ambient_alert_min;
 | |
| 			return 0;
 | |
| 		case POWER_SUPPLY_PROP_TEMP_AMBIENT_ALERT_MAX:
 | |
| 			val->intval = info->temp_ambient_alert_max;
 | |
| 			return 0;
 | |
| 		case POWER_SUPPLY_PROP_TEMP_ALERT_MIN:
 | |
| 			val->intval = info->temp_alert_min;
 | |
| 			return 0;
 | |
| 		case POWER_SUPPLY_PROP_TEMP_ALERT_MAX:
 | |
| 			val->intval = info->temp_alert_max;
 | |
| 			return 0;
 | |
| 		case POWER_SUPPLY_PROP_TEMP_MIN:
 | |
| 			val->intval = info->temp_min;
 | |
| 			return 0;
 | |
| 		case POWER_SUPPLY_PROP_TEMP_MAX:
 | |
| 			val->intval = info->temp_max;
 | |
| 			return 0;
 | |
| 		default:
 | |
| 			return -EINVAL;
 | |
| 	}
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(power_supply_battery_info_get_prop);
 | |
| 
 | |
| /**
 | |
|  * power_supply_temp2resist_simple() - find the battery internal resistance
 | |
|  * percent from temperature
 | |
|  * @table: Pointer to battery resistance temperature table
 | |
|  * @table_len: The table length
 | |
|  * @temp: Current temperature
 | |
|  *
 | |
|  * This helper function is used to look up battery internal resistance percent
 | |
|  * according to current temperature value from the resistance temperature table,
 | |
|  * and the table must be ordered descending. Then the actual battery internal
 | |
|  * resistance = the ideal battery internal resistance * percent / 100.
 | |
|  *
 | |
|  * Return: the battery internal resistance percent
 | |
|  */
 | |
| int power_supply_temp2resist_simple(struct power_supply_resistance_temp_table *table,
 | |
| 				    int table_len, int temp)
 | |
| {
 | |
| 	int i, high, low;
 | |
| 
 | |
| 	for (i = 0; i < table_len; i++)
 | |
| 		if (temp > table[i].temp)
 | |
| 			break;
 | |
| 
 | |
| 	/* The library function will deal with high == low */
 | |
| 	if (i == 0)
 | |
| 		high = low = i;
 | |
| 	else if (i == table_len)
 | |
| 		high = low = i - 1;
 | |
| 	else
 | |
| 		high = (low = i) - 1;
 | |
| 
 | |
| 	return fixp_linear_interpolate(table[low].temp,
 | |
| 				       table[low].resistance,
 | |
| 				       table[high].temp,
 | |
| 				       table[high].resistance,
 | |
| 				       temp);
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(power_supply_temp2resist_simple);
 | |
| 
 | |
| /**
 | |
|  * power_supply_vbat2ri() - find the battery internal resistance
 | |
|  * from the battery voltage
 | |
|  * @info: The battery information container
 | |
|  * @vbat_uv: The battery voltage in microvolt
 | |
|  * @charging: If we are charging (true) or not (false)
 | |
|  *
 | |
|  * This helper function is used to look up battery internal resistance
 | |
|  * according to current battery voltage. Depending on whether the battery
 | |
|  * is currently charging or not, different resistance will be returned.
 | |
|  *
 | |
|  * Returns the internal resistance in microohm or negative error code.
 | |
|  */
 | |
| int power_supply_vbat2ri(struct power_supply_battery_info *info,
 | |
| 			 int vbat_uv, bool charging)
 | |
| {
 | |
| 	struct power_supply_vbat_ri_table *vbat2ri;
 | |
| 	int table_len;
 | |
| 	int i, high, low;
 | |
| 
 | |
| 	/*
 | |
| 	 * If we are charging, and the battery supplies a separate table
 | |
| 	 * for this state, we use that in order to compensate for the
 | |
| 	 * charging voltage. Otherwise we use the main table.
 | |
| 	 */
 | |
| 	if (charging && info->vbat2ri_charging) {
 | |
| 		vbat2ri = info->vbat2ri_charging;
 | |
| 		table_len = info->vbat2ri_charging_size;
 | |
| 	} else {
 | |
| 		vbat2ri = info->vbat2ri_discharging;
 | |
| 		table_len = info->vbat2ri_discharging_size;
 | |
| 	}
 | |
| 
 | |
| 	/*
 | |
| 	 * If no tables are specified, or if we are above the highest voltage in
 | |
| 	 * the voltage table, just return the factory specified internal resistance.
 | |
| 	 */
 | |
| 	if (!vbat2ri || (table_len <= 0) || (vbat_uv > vbat2ri[0].vbat_uv)) {
 | |
| 		if (charging && (info->factory_internal_resistance_charging_uohm > 0))
 | |
| 			return info->factory_internal_resistance_charging_uohm;
 | |
| 		else
 | |
| 			return info->factory_internal_resistance_uohm;
 | |
| 	}
 | |
| 
 | |
| 	/* Break loop at table_len - 1 because that is the highest index */
 | |
| 	for (i = 0; i < table_len - 1; i++)
 | |
| 		if (vbat_uv > vbat2ri[i].vbat_uv)
 | |
| 			break;
 | |
| 
 | |
| 	/* The library function will deal with high == low */
 | |
| 	if ((i == 0) || (i == (table_len - 1)))
 | |
| 		high = i;
 | |
| 	else
 | |
| 		high = i - 1;
 | |
| 	low = i;
 | |
| 
 | |
| 	return fixp_linear_interpolate(vbat2ri[low].vbat_uv,
 | |
| 				       vbat2ri[low].ri_uohm,
 | |
| 				       vbat2ri[high].vbat_uv,
 | |
| 				       vbat2ri[high].ri_uohm,
 | |
| 				       vbat_uv);
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(power_supply_vbat2ri);
 | |
| 
 | |
| struct power_supply_maintenance_charge_table *
 | |
| power_supply_get_maintenance_charging_setting(struct power_supply_battery_info *info,
 | |
| 					      int index)
 | |
| {
 | |
| 	if (index >= info->maintenance_charge_size)
 | |
| 		return NULL;
 | |
| 	return &info->maintenance_charge[index];
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(power_supply_get_maintenance_charging_setting);
 | |
| 
 | |
| /**
 | |
|  * power_supply_ocv2cap_simple() - find the battery capacity
 | |
|  * @table: Pointer to battery OCV lookup table
 | |
|  * @table_len: OCV table length
 | |
|  * @ocv: Current OCV value
 | |
|  *
 | |
|  * This helper function is used to look up battery capacity according to
 | |
|  * current OCV value from one OCV table, and the OCV table must be ordered
 | |
|  * descending.
 | |
|  *
 | |
|  * Return: the battery capacity.
 | |
|  */
 | |
| int power_supply_ocv2cap_simple(struct power_supply_battery_ocv_table *table,
 | |
| 				int table_len, int ocv)
 | |
| {
 | |
| 	int i, high, low;
 | |
| 
 | |
| 	for (i = 0; i < table_len; i++)
 | |
| 		if (ocv > table[i].ocv)
 | |
| 			break;
 | |
| 
 | |
| 	/* The library function will deal with high == low */
 | |
| 	if (i == 0)
 | |
| 		high = low = i;
 | |
| 	else if (i == table_len)
 | |
| 		high = low = i - 1;
 | |
| 	else
 | |
| 		high = (low = i) - 1;
 | |
| 
 | |
| 	return fixp_linear_interpolate(table[low].ocv,
 | |
| 				       table[low].capacity,
 | |
| 				       table[high].ocv,
 | |
| 				       table[high].capacity,
 | |
| 				       ocv);
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(power_supply_ocv2cap_simple);
 | |
| 
 | |
| struct power_supply_battery_ocv_table *
 | |
| power_supply_find_ocv2cap_table(struct power_supply_battery_info *info,
 | |
| 				int temp, int *table_len)
 | |
| {
 | |
| 	int best_temp_diff = INT_MAX, temp_diff;
 | |
| 	u8 i, best_index = 0;
 | |
| 
 | |
| 	if (!info->ocv_table[0])
 | |
| 		return NULL;
 | |
| 
 | |
| 	for (i = 0; i < POWER_SUPPLY_OCV_TEMP_MAX; i++) {
 | |
| 		/* Out of capacity tables */
 | |
| 		if (!info->ocv_table[i])
 | |
| 			break;
 | |
| 
 | |
| 		temp_diff = abs(info->ocv_temp[i] - temp);
 | |
| 
 | |
| 		if (temp_diff < best_temp_diff) {
 | |
| 			best_temp_diff = temp_diff;
 | |
| 			best_index = i;
 | |
| 		}
 | |
| 	}
 | |
| 
 | |
| 	*table_len = info->ocv_table_size[best_index];
 | |
| 	return info->ocv_table[best_index];
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(power_supply_find_ocv2cap_table);
 | |
| 
 | |
| int power_supply_batinfo_ocv2cap(struct power_supply_battery_info *info,
 | |
| 				 int ocv, int temp)
 | |
| {
 | |
| 	struct power_supply_battery_ocv_table *table;
 | |
| 	int table_len;
 | |
| 
 | |
| 	table = power_supply_find_ocv2cap_table(info, temp, &table_len);
 | |
| 	if (!table)
 | |
| 		return -EINVAL;
 | |
| 
 | |
| 	return power_supply_ocv2cap_simple(table, table_len, ocv);
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(power_supply_batinfo_ocv2cap);
 | |
| 
 | |
| bool power_supply_battery_bti_in_range(struct power_supply_battery_info *info,
 | |
| 				       int resistance)
 | |
| {
 | |
| 	int low, high;
 | |
| 
 | |
| 	/* Nothing like this can be checked */
 | |
| 	if (info->bti_resistance_ohm <= 0)
 | |
| 		return false;
 | |
| 
 | |
| 	/* This will be extremely strict and unlikely to work */
 | |
| 	if (info->bti_resistance_tolerance <= 0)
 | |
| 		return (info->bti_resistance_ohm == resistance);
 | |
| 
 | |
| 	low = info->bti_resistance_ohm -
 | |
| 		(info->bti_resistance_ohm * info->bti_resistance_tolerance) / 100;
 | |
| 	high = info->bti_resistance_ohm +
 | |
| 		(info->bti_resistance_ohm * info->bti_resistance_tolerance) / 100;
 | |
| 
 | |
| 	return ((resistance >= low) && (resistance <= high));
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(power_supply_battery_bti_in_range);
 | |
| 
 | |
| static bool psy_has_property(const struct power_supply_desc *psy_desc,
 | |
| 			     enum power_supply_property psp)
 | |
| {
 | |
| 	bool found = false;
 | |
| 	int i;
 | |
| 
 | |
| 	for (i = 0; i < psy_desc->num_properties; i++) {
 | |
| 		if (psy_desc->properties[i] == psp) {
 | |
| 			found = true;
 | |
| 			break;
 | |
| 		}
 | |
| 	}
 | |
| 
 | |
| 	return found;
 | |
| }
 | |
| 
 | |
| int power_supply_get_property(struct power_supply *psy,
 | |
| 			    enum power_supply_property psp,
 | |
| 			    union power_supply_propval *val)
 | |
| {
 | |
| 	if (atomic_read(&psy->use_cnt) <= 0) {
 | |
| 		if (!psy->initialized)
 | |
| 			return -EAGAIN;
 | |
| 		return -ENODEV;
 | |
| 	}
 | |
| 
 | |
| 	if (psy_has_property(psy->desc, psp))
 | |
| 		return psy->desc->get_property(psy, psp, val);
 | |
| 	else if (power_supply_battery_info_has_prop(psy->battery_info, psp))
 | |
| 		return power_supply_battery_info_get_prop(psy->battery_info, psp, val);
 | |
| 	else
 | |
| 		return -EINVAL;
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(power_supply_get_property);
 | |
| 
 | |
| int power_supply_set_property(struct power_supply *psy,
 | |
| 			    enum power_supply_property psp,
 | |
| 			    const union power_supply_propval *val)
 | |
| {
 | |
| 	if (atomic_read(&psy->use_cnt) <= 0 || !psy->desc->set_property)
 | |
| 		return -ENODEV;
 | |
| 
 | |
| 	return psy->desc->set_property(psy, psp, val);
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(power_supply_set_property);
 | |
| 
 | |
| int power_supply_property_is_writeable(struct power_supply *psy,
 | |
| 					enum power_supply_property psp)
 | |
| {
 | |
| 	if (atomic_read(&psy->use_cnt) <= 0 ||
 | |
| 			!psy->desc->property_is_writeable)
 | |
| 		return -ENODEV;
 | |
| 
 | |
| 	return psy->desc->property_is_writeable(psy, psp);
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(power_supply_property_is_writeable);
 | |
| 
 | |
| void power_supply_external_power_changed(struct power_supply *psy)
 | |
| {
 | |
| 	if (atomic_read(&psy->use_cnt) <= 0 ||
 | |
| 			!psy->desc->external_power_changed)
 | |
| 		return;
 | |
| 
 | |
| 	psy->desc->external_power_changed(psy);
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(power_supply_external_power_changed);
 | |
| 
 | |
| int power_supply_powers(struct power_supply *psy, struct device *dev)
 | |
| {
 | |
| 	return sysfs_create_link(&psy->dev.kobj, &dev->kobj, "powers");
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(power_supply_powers);
 | |
| 
 | |
| static void power_supply_dev_release(struct device *dev)
 | |
| {
 | |
| 	struct power_supply *psy = to_power_supply(dev);
 | |
| 	dev_dbg(dev, "%s\n", __func__);
 | |
| 	kfree(psy);
 | |
| }
 | |
| 
 | |
| int power_supply_reg_notifier(struct notifier_block *nb)
 | |
| {
 | |
| 	return atomic_notifier_chain_register(&power_supply_notifier, nb);
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(power_supply_reg_notifier);
 | |
| 
 | |
| void power_supply_unreg_notifier(struct notifier_block *nb)
 | |
| {
 | |
| 	atomic_notifier_chain_unregister(&power_supply_notifier, nb);
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(power_supply_unreg_notifier);
 | |
| 
 | |
| #ifdef CONFIG_THERMAL
 | |
| static int power_supply_read_temp(struct thermal_zone_device *tzd,
 | |
| 		int *temp)
 | |
| {
 | |
| 	struct power_supply *psy;
 | |
| 	union power_supply_propval val;
 | |
| 	int ret;
 | |
| 
 | |
| 	WARN_ON(tzd == NULL);
 | |
| 	psy = thermal_zone_device_priv(tzd);
 | |
| 	ret = power_supply_get_property(psy, POWER_SUPPLY_PROP_TEMP, &val);
 | |
| 	if (ret)
 | |
| 		return ret;
 | |
| 
 | |
| 	/* Convert tenths of degree Celsius to milli degree Celsius. */
 | |
| 	*temp = val.intval * 100;
 | |
| 
 | |
| 	return ret;
 | |
| }
 | |
| 
 | |
| static struct thermal_zone_device_ops psy_tzd_ops = {
 | |
| 	.get_temp = power_supply_read_temp,
 | |
| };
 | |
| 
 | |
| static int psy_register_thermal(struct power_supply *psy)
 | |
| {
 | |
| 	int ret;
 | |
| 
 | |
| 	if (psy->desc->no_thermal)
 | |
| 		return 0;
 | |
| 
 | |
| 	/* Register battery zone device psy reports temperature */
 | |
| 	if (psy_has_property(psy->desc, POWER_SUPPLY_PROP_TEMP)) {
 | |
| 		/* Prefer our hwmon device and avoid duplicates */
 | |
| 		struct thermal_zone_params tzp = {
 | |
| 			.no_hwmon = IS_ENABLED(CONFIG_POWER_SUPPLY_HWMON)
 | |
| 		};
 | |
| 		psy->tzd = thermal_tripless_zone_device_register(psy->desc->name,
 | |
| 				psy, &psy_tzd_ops, &tzp);
 | |
| 		if (IS_ERR(psy->tzd))
 | |
| 			return PTR_ERR(psy->tzd);
 | |
| 		ret = thermal_zone_device_enable(psy->tzd);
 | |
| 		if (ret)
 | |
| 			thermal_zone_device_unregister(psy->tzd);
 | |
| 		return ret;
 | |
| 	}
 | |
| 
 | |
| 	return 0;
 | |
| }
 | |
| 
 | |
| static void psy_unregister_thermal(struct power_supply *psy)
 | |
| {
 | |
| 	if (IS_ERR_OR_NULL(psy->tzd))
 | |
| 		return;
 | |
| 	thermal_zone_device_unregister(psy->tzd);
 | |
| }
 | |
| 
 | |
| #else
 | |
| static int psy_register_thermal(struct power_supply *psy)
 | |
| {
 | |
| 	return 0;
 | |
| }
 | |
| 
 | |
| static void psy_unregister_thermal(struct power_supply *psy)
 | |
| {
 | |
| }
 | |
| #endif
 | |
| 
 | |
| static struct power_supply *__must_check
 | |
| __power_supply_register(struct device *parent,
 | |
| 				   const struct power_supply_desc *desc,
 | |
| 				   const struct power_supply_config *cfg,
 | |
| 				   bool ws)
 | |
| {
 | |
| 	struct device *dev;
 | |
| 	struct power_supply *psy;
 | |
| 	int rc;
 | |
| 
 | |
| 	if (!desc || !desc->name || !desc->properties || !desc->num_properties)
 | |
| 		return ERR_PTR(-EINVAL);
 | |
| 
 | |
| 	if (!parent)
 | |
| 		pr_warn("%s: Expected proper parent device for '%s'\n",
 | |
| 			__func__, desc->name);
 | |
| 
 | |
| 	psy = kzalloc(sizeof(*psy), GFP_KERNEL);
 | |
| 	if (!psy)
 | |
| 		return ERR_PTR(-ENOMEM);
 | |
| 
 | |
| 	dev = &psy->dev;
 | |
| 
 | |
| 	device_initialize(dev);
 | |
| 
 | |
| 	dev->class = power_supply_class;
 | |
| 	dev->type = &power_supply_dev_type;
 | |
| 	dev->parent = parent;
 | |
| 	dev->release = power_supply_dev_release;
 | |
| 	dev_set_drvdata(dev, psy);
 | |
| 	psy->desc = desc;
 | |
| 	if (cfg) {
 | |
| 		dev->groups = cfg->attr_grp;
 | |
| 		psy->drv_data = cfg->drv_data;
 | |
| 		psy->of_node =
 | |
| 			cfg->fwnode ? to_of_node(cfg->fwnode) : cfg->of_node;
 | |
| 		psy->supplied_to = cfg->supplied_to;
 | |
| 		psy->num_supplicants = cfg->num_supplicants;
 | |
| 	}
 | |
| 
 | |
| 	rc = dev_set_name(dev, "%s", desc->name);
 | |
| 	if (rc)
 | |
| 		goto dev_set_name_failed;
 | |
| 
 | |
| 	INIT_WORK(&psy->changed_work, power_supply_changed_work);
 | |
| 	INIT_DELAYED_WORK(&psy->deferred_register_work,
 | |
| 			  power_supply_deferred_register_work);
 | |
| 
 | |
| 	rc = power_supply_check_supplies(psy);
 | |
| 	if (rc) {
 | |
| 		dev_dbg(dev, "Not all required supplies found, defer probe\n");
 | |
| 		goto check_supplies_failed;
 | |
| 	}
 | |
| 
 | |
| 	/*
 | |
| 	 * Expose constant battery info, if it is available. While there are
 | |
| 	 * some chargers accessing constant battery data, we only want to
 | |
| 	 * expose battery data to userspace for battery devices.
 | |
| 	 */
 | |
| 	if (desc->type == POWER_SUPPLY_TYPE_BATTERY) {
 | |
| 		rc = power_supply_get_battery_info(psy, &psy->battery_info);
 | |
| 		if (rc && rc != -ENODEV && rc != -ENOENT)
 | |
| 			goto check_supplies_failed;
 | |
| 	}
 | |
| 
 | |
| 	spin_lock_init(&psy->changed_lock);
 | |
| 	rc = device_add(dev);
 | |
| 	if (rc)
 | |
| 		goto device_add_failed;
 | |
| 
 | |
| 	rc = device_init_wakeup(dev, ws);
 | |
| 	if (rc)
 | |
| 		goto wakeup_init_failed;
 | |
| 
 | |
| 	rc = psy_register_thermal(psy);
 | |
| 	if (rc)
 | |
| 		goto register_thermal_failed;
 | |
| 
 | |
| 	rc = power_supply_create_triggers(psy);
 | |
| 	if (rc)
 | |
| 		goto create_triggers_failed;
 | |
| 
 | |
| 	rc = power_supply_add_hwmon_sysfs(psy);
 | |
| 	if (rc)
 | |
| 		goto add_hwmon_sysfs_failed;
 | |
| 
 | |
| 	/*
 | |
| 	 * Update use_cnt after any uevents (most notably from device_add()).
 | |
| 	 * We are here still during driver's probe but
 | |
| 	 * the power_supply_uevent() calls back driver's get_property
 | |
| 	 * method so:
 | |
| 	 * 1. Driver did not assigned the returned struct power_supply,
 | |
| 	 * 2. Driver could not finish initialization (anything in its probe
 | |
| 	 *    after calling power_supply_register()).
 | |
| 	 */
 | |
| 	atomic_inc(&psy->use_cnt);
 | |
| 	psy->initialized = true;
 | |
| 
 | |
| 	queue_delayed_work(system_power_efficient_wq,
 | |
| 			   &psy->deferred_register_work,
 | |
| 			   POWER_SUPPLY_DEFERRED_REGISTER_TIME);
 | |
| 
 | |
| 	return psy;
 | |
| 
 | |
| add_hwmon_sysfs_failed:
 | |
| 	power_supply_remove_triggers(psy);
 | |
| create_triggers_failed:
 | |
| 	psy_unregister_thermal(psy);
 | |
| register_thermal_failed:
 | |
| wakeup_init_failed:
 | |
| 	device_del(dev);
 | |
| device_add_failed:
 | |
| check_supplies_failed:
 | |
| dev_set_name_failed:
 | |
| 	put_device(dev);
 | |
| 	return ERR_PTR(rc);
 | |
| }
 | |
| 
 | |
| /**
 | |
|  * power_supply_register() - Register new power supply
 | |
|  * @parent:	Device to be a parent of power supply's device, usually
 | |
|  *		the device which probe function calls this
 | |
|  * @desc:	Description of power supply, must be valid through whole
 | |
|  *		lifetime of this power supply
 | |
|  * @cfg:	Run-time specific configuration accessed during registering,
 | |
|  *		may be NULL
 | |
|  *
 | |
|  * Return: A pointer to newly allocated power_supply on success
 | |
|  * or ERR_PTR otherwise.
 | |
|  * Use power_supply_unregister() on returned power_supply pointer to release
 | |
|  * resources.
 | |
|  */
 | |
| struct power_supply *__must_check power_supply_register(struct device *parent,
 | |
| 		const struct power_supply_desc *desc,
 | |
| 		const struct power_supply_config *cfg)
 | |
| {
 | |
| 	return __power_supply_register(parent, desc, cfg, true);
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(power_supply_register);
 | |
| 
 | |
| /**
 | |
|  * power_supply_register_no_ws() - Register new non-waking-source power supply
 | |
|  * @parent:	Device to be a parent of power supply's device, usually
 | |
|  *		the device which probe function calls this
 | |
|  * @desc:	Description of power supply, must be valid through whole
 | |
|  *		lifetime of this power supply
 | |
|  * @cfg:	Run-time specific configuration accessed during registering,
 | |
|  *		may be NULL
 | |
|  *
 | |
|  * Return: A pointer to newly allocated power_supply on success
 | |
|  * or ERR_PTR otherwise.
 | |
|  * Use power_supply_unregister() on returned power_supply pointer to release
 | |
|  * resources.
 | |
|  */
 | |
| struct power_supply *__must_check
 | |
| power_supply_register_no_ws(struct device *parent,
 | |
| 		const struct power_supply_desc *desc,
 | |
| 		const struct power_supply_config *cfg)
 | |
| {
 | |
| 	return __power_supply_register(parent, desc, cfg, false);
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(power_supply_register_no_ws);
 | |
| 
 | |
| static void devm_power_supply_release(struct device *dev, void *res)
 | |
| {
 | |
| 	struct power_supply **psy = res;
 | |
| 
 | |
| 	power_supply_unregister(*psy);
 | |
| }
 | |
| 
 | |
| /**
 | |
|  * devm_power_supply_register() - Register managed power supply
 | |
|  * @parent:	Device to be a parent of power supply's device, usually
 | |
|  *		the device which probe function calls this
 | |
|  * @desc:	Description of power supply, must be valid through whole
 | |
|  *		lifetime of this power supply
 | |
|  * @cfg:	Run-time specific configuration accessed during registering,
 | |
|  *		may be NULL
 | |
|  *
 | |
|  * Return: A pointer to newly allocated power_supply on success
 | |
|  * or ERR_PTR otherwise.
 | |
|  * The returned power_supply pointer will be automatically unregistered
 | |
|  * on driver detach.
 | |
|  */
 | |
| struct power_supply *__must_check
 | |
| devm_power_supply_register(struct device *parent,
 | |
| 		const struct power_supply_desc *desc,
 | |
| 		const struct power_supply_config *cfg)
 | |
| {
 | |
| 	struct power_supply **ptr, *psy;
 | |
| 
 | |
| 	ptr = devres_alloc(devm_power_supply_release, sizeof(*ptr), GFP_KERNEL);
 | |
| 
 | |
| 	if (!ptr)
 | |
| 		return ERR_PTR(-ENOMEM);
 | |
| 	psy = __power_supply_register(parent, desc, cfg, true);
 | |
| 	if (IS_ERR(psy)) {
 | |
| 		devres_free(ptr);
 | |
| 	} else {
 | |
| 		*ptr = psy;
 | |
| 		devres_add(parent, ptr);
 | |
| 	}
 | |
| 	return psy;
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(devm_power_supply_register);
 | |
| 
 | |
| /**
 | |
|  * devm_power_supply_register_no_ws() - Register managed non-waking-source power supply
 | |
|  * @parent:	Device to be a parent of power supply's device, usually
 | |
|  *		the device which probe function calls this
 | |
|  * @desc:	Description of power supply, must be valid through whole
 | |
|  *		lifetime of this power supply
 | |
|  * @cfg:	Run-time specific configuration accessed during registering,
 | |
|  *		may be NULL
 | |
|  *
 | |
|  * Return: A pointer to newly allocated power_supply on success
 | |
|  * or ERR_PTR otherwise.
 | |
|  * The returned power_supply pointer will be automatically unregistered
 | |
|  * on driver detach.
 | |
|  */
 | |
| struct power_supply *__must_check
 | |
| devm_power_supply_register_no_ws(struct device *parent,
 | |
| 		const struct power_supply_desc *desc,
 | |
| 		const struct power_supply_config *cfg)
 | |
| {
 | |
| 	struct power_supply **ptr, *psy;
 | |
| 
 | |
| 	ptr = devres_alloc(devm_power_supply_release, sizeof(*ptr), GFP_KERNEL);
 | |
| 
 | |
| 	if (!ptr)
 | |
| 		return ERR_PTR(-ENOMEM);
 | |
| 	psy = __power_supply_register(parent, desc, cfg, false);
 | |
| 	if (IS_ERR(psy)) {
 | |
| 		devres_free(ptr);
 | |
| 	} else {
 | |
| 		*ptr = psy;
 | |
| 		devres_add(parent, ptr);
 | |
| 	}
 | |
| 	return psy;
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(devm_power_supply_register_no_ws);
 | |
| 
 | |
| /**
 | |
|  * power_supply_unregister() - Remove this power supply from system
 | |
|  * @psy:	Pointer to power supply to unregister
 | |
|  *
 | |
|  * Remove this power supply from the system. The resources of power supply
 | |
|  * will be freed here or on last power_supply_put() call.
 | |
|  */
 | |
| void power_supply_unregister(struct power_supply *psy)
 | |
| {
 | |
| 	WARN_ON(atomic_dec_return(&psy->use_cnt));
 | |
| 	psy->removing = true;
 | |
| 	cancel_work_sync(&psy->changed_work);
 | |
| 	cancel_delayed_work_sync(&psy->deferred_register_work);
 | |
| 	sysfs_remove_link(&psy->dev.kobj, "powers");
 | |
| 	power_supply_remove_hwmon_sysfs(psy);
 | |
| 	power_supply_remove_triggers(psy);
 | |
| 	psy_unregister_thermal(psy);
 | |
| 	device_init_wakeup(&psy->dev, false);
 | |
| 	device_unregister(&psy->dev);
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(power_supply_unregister);
 | |
| 
 | |
| void *power_supply_get_drvdata(struct power_supply *psy)
 | |
| {
 | |
| 	return psy->drv_data;
 | |
| }
 | |
| EXPORT_SYMBOL_GPL(power_supply_get_drvdata);
 | |
| 
 | |
| static int __init power_supply_class_init(void)
 | |
| {
 | |
| 	power_supply_class = class_create("power_supply");
 | |
| 
 | |
| 	if (IS_ERR(power_supply_class))
 | |
| 		return PTR_ERR(power_supply_class);
 | |
| 
 | |
| 	power_supply_class->dev_uevent = power_supply_uevent;
 | |
| 	power_supply_init_attrs(&power_supply_dev_type);
 | |
| 
 | |
| 	return 0;
 | |
| }
 | |
| 
 | |
| static void __exit power_supply_class_exit(void)
 | |
| {
 | |
| 	class_destroy(power_supply_class);
 | |
| }
 | |
| 
 | |
| subsys_initcall(power_supply_class_init);
 | |
| module_exit(power_supply_class_exit);
 | |
| 
 | |
| MODULE_DESCRIPTION("Universal power supply monitor class");
 | |
| MODULE_AUTHOR("Ian Molton <spyro@f2s.com>, "
 | |
| 	      "Szabolcs Gyurko, "
 | |
| 	      "Anton Vorontsov <cbou@mail.ru>");
 | |
| MODULE_LICENSE("GPL");
 |