First of all, what I know about uGuru is no fact based on any help, hints or
 | 
						|
datasheet from Abit. The data I have got on uGuru have I assembled through
 | 
						|
my weak knowledge in "backwards engineering".
 | 
						|
And just for the record, you may have noticed uGuru isn't a chip developed by
 | 
						|
Abit, as they claim it to be. It's really just an microprocessor (uC) created by
 | 
						|
Winbond (W83L950D). And no, reading the manual for this specific uC or
 | 
						|
mailing  Windbond for help won't give any useful data about uGuru, as it is
 | 
						|
the program inside the uC that is responding to calls.
 | 
						|
 | 
						|
Olle Sandberg <ollebull@gmail.com>, 2005-05-25
 | 
						|
 | 
						|
 | 
						|
Original version by Olle Sandberg who did the heavy lifting of the initial
 | 
						|
reverse engineering. This version has been almost fully rewritten for clarity
 | 
						|
and extended with write support and info on more databanks, the write support
 | 
						|
is once again reverse engineered by Olle the additional databanks have been
 | 
						|
reverse engineered by me. I would like to express my thanks to Olle, this
 | 
						|
document and the Linux driver could not have been written without his efforts.
 | 
						|
 | 
						|
Note: because of the lack of specs only the sensors part of the uGuru is
 | 
						|
described here and not the CPU / RAM / etc voltage & frequency control.
 | 
						|
 | 
						|
Hans de Goede <j.w.r.degoede@hhs.nl>, 28-01-2006
 | 
						|
 | 
						|
 | 
						|
Detection
 | 
						|
=========
 | 
						|
 | 
						|
As far as known the uGuru is always placed at and using the (ISA) I/O-ports
 | 
						|
0xE0 and 0xE4, so we don't have to scan any port-range, just check what the two
 | 
						|
ports are holding for detection. We will refer to 0xE0 as CMD (command-port)
 | 
						|
and 0xE4 as DATA because Abit refers to them with these names.
 | 
						|
 | 
						|
If DATA holds 0x00 or 0x08 and CMD holds 0x00 or 0xAC an uGuru could be
 | 
						|
present. We have to check for two different values at data-port, because
 | 
						|
after a reboot uGuru will hold 0x00 here, but if the driver is removed and
 | 
						|
later on attached again data-port will hold 0x08, more about this later.
 | 
						|
 | 
						|
After wider testing of the Linux kernel driver some variants of the uGuru have
 | 
						|
turned up which will hold 0x00 instead of 0xAC at the CMD port, thus we also
 | 
						|
have to test CMD for two different values. On these uGuru's DATA will initially
 | 
						|
hold 0x09 and will only hold 0x08 after reading CMD first, so CMD must be read
 | 
						|
first!
 | 
						|
 | 
						|
To be really sure an uGuru is present a test read of one or more register
 | 
						|
sets should be done.
 | 
						|
 | 
						|
 | 
						|
Reading / Writing
 | 
						|
=================
 | 
						|
 | 
						|
Addressing
 | 
						|
----------
 | 
						|
 | 
						|
The uGuru has a number of different addressing levels. The first addressing
 | 
						|
level we will call banks. A bank holds data for one or more sensors. The data
 | 
						|
in a bank for a sensor is one or more bytes large.
 | 
						|
 | 
						|
The number of bytes is fixed for a given bank, you should always read or write
 | 
						|
that many bytes, reading / writing more will fail, the results when writing
 | 
						|
less then the number of bytes for a given bank are undetermined.
 | 
						|
 | 
						|
See below for all known bank addresses, numbers of sensors in that bank,
 | 
						|
number of bytes data per sensor and contents/meaning of those bytes.
 | 
						|
 | 
						|
Although both this document and the kernel driver have kept the sensor
 | 
						|
terminoligy for the addressing within a bank this is not 100% correct, in
 | 
						|
bank 0x24 for example the addressing within the bank selects a PWM output not
 | 
						|
a sensor.
 | 
						|
 | 
						|
Notice that some banks have both a read and a write address this is how the
 | 
						|
uGuru determines if a read from or a write to the bank is taking place, thus
 | 
						|
when reading you should always use the read address and when writing the
 | 
						|
write address. The write address is always one (1) more than the read address.
 | 
						|
 | 
						|
 | 
						|
uGuru ready
 | 
						|
-----------
 | 
						|
 | 
						|
Before you can read from or write to the uGuru you must first put the uGuru
 | 
						|
in "ready" mode.
 | 
						|
 | 
						|
To put the uGuru in ready mode first write 0x00 to DATA and then wait for DATA
 | 
						|
to hold 0x09, DATA should read 0x09 within 250 read cycles.
 | 
						|
 | 
						|
Next CMD _must_ be read and should hold 0xAC, usually CMD will hold 0xAC the
 | 
						|
first read but sometimes it takes a while before CMD holds 0xAC and thus it
 | 
						|
has to be read a number of times (max 50).
 | 
						|
 | 
						|
After reading CMD, DATA should hold 0x08 which means that the uGuru is ready
 | 
						|
for input. As above DATA will usually hold 0x08 the first read but not always.
 | 
						|
This step can be skipped, but it is undetermined what happens if the uGuru has
 | 
						|
not yet reported 0x08 at DATA and you proceed with writing a bank address.
 | 
						|
 | 
						|
 | 
						|
Sending bank and sensor addresses to the uGuru
 | 
						|
----------------------------------------------
 | 
						|
 | 
						|
First the uGuru must be in "ready" mode as described above, DATA should hold
 | 
						|
0x08 indicating that the uGuru wants input, in this case the bank address.
 | 
						|
 | 
						|
Next write the bank address to DATA. After the bank address has been written
 | 
						|
wait for to DATA to hold 0x08 again indicating that it wants / is ready for
 | 
						|
more input (max 250 reads).
 | 
						|
 | 
						|
Once DATA holds 0x08 again write the sensor address to CMD.
 | 
						|
 | 
						|
 | 
						|
Reading
 | 
						|
-------
 | 
						|
 | 
						|
First send the bank and sensor addresses as described above.
 | 
						|
Then for each byte of data you want to read wait for DATA to hold 0x01
 | 
						|
which indicates that the uGuru is ready to be read (max 250 reads) and once
 | 
						|
DATA holds 0x01 read the byte from CMD.
 | 
						|
 | 
						|
Once all bytes have been read data will hold 0x09, but there is no reason to
 | 
						|
test for this. Notice that the number of bytes is bank address dependent see
 | 
						|
above and below.
 | 
						|
 | 
						|
After completing a successful read it is advised to put the uGuru back in
 | 
						|
ready mode, so that it is ready for the next read / write cycle. This way
 | 
						|
if your program / driver is unloaded and later loaded again the detection
 | 
						|
algorithm described above will still work.
 | 
						|
 | 
						|
 | 
						|
 | 
						|
Writing
 | 
						|
-------
 | 
						|
 | 
						|
First send the bank and sensor addresses as described above.
 | 
						|
Then for each byte of data you want to write wait for DATA to hold 0x00
 | 
						|
which indicates that the uGuru is ready to be written (max 250 reads) and
 | 
						|
once DATA holds 0x00 write the byte to CMD.
 | 
						|
 | 
						|
Once all bytes have been written wait for DATA to hold 0x01 (max 250 reads)
 | 
						|
don't ask why this is the way it is.
 | 
						|
 | 
						|
Once DATA holds 0x01 read CMD it should hold 0xAC now.
 | 
						|
 | 
						|
After completing a successful write it is advised to put the uGuru back in
 | 
						|
ready mode, so that it is ready for the next read / write cycle. This way
 | 
						|
if your program / driver is unloaded and later loaded again the detection
 | 
						|
algorithm described above will still work.
 | 
						|
 | 
						|
 | 
						|
Gotchas
 | 
						|
-------
 | 
						|
 | 
						|
After wider testing of the Linux kernel driver some variants of the uGuru have
 | 
						|
turned up which do not hold 0x08 at DATA within 250 reads after writing the
 | 
						|
bank address. With these versions this happens quite frequent, using larger
 | 
						|
timeouts doesn't help, they just go offline for a second or 2, doing some
 | 
						|
internal callibration or whatever. Your code should be prepared to handle
 | 
						|
this and in case of no response in this specific case just goto sleep for a
 | 
						|
while and then retry.
 | 
						|
 | 
						|
 | 
						|
Address Map
 | 
						|
===========
 | 
						|
 | 
						|
Bank 0x20 Alarms (R)
 | 
						|
--------------------
 | 
						|
This bank contains 0 sensors, iow the sensor address is ignored (but must be
 | 
						|
written) just use 0. Bank 0x20 contains 3 bytes:
 | 
						|
 | 
						|
Byte 0:
 | 
						|
This byte holds the alarm flags for sensor 0-7 of Sensor Bank1, with bit 0
 | 
						|
corresponding to sensor 0, 1 to 1, etc.
 | 
						|
 | 
						|
Byte 1:
 | 
						|
This byte holds the alarm flags for sensor 8-15 of Sensor Bank1, with bit 0
 | 
						|
corresponding to sensor 8, 1 to 9, etc.
 | 
						|
 | 
						|
Byte 2:
 | 
						|
This byte holds the alarm flags for sensor 0-5 of Sensor Bank2, with bit 0
 | 
						|
corresponding to sensor 0, 1 to 1, etc.
 | 
						|
 | 
						|
 | 
						|
Bank 0x21 Sensor Bank1 Values / Readings (R)
 | 
						|
--------------------------------------------
 | 
						|
This bank contains 16 sensors, for each sensor it contains 1 byte.
 | 
						|
So far the following sensors are known to be available on all motherboards:
 | 
						|
Sensor  0 CPU temp
 | 
						|
Sensor  1 SYS temp
 | 
						|
Sensor  3 CPU core volt
 | 
						|
Sensor  4 DDR volt
 | 
						|
Sensor 10 DDR Vtt volt
 | 
						|
Sensor 15 PWM temp
 | 
						|
 | 
						|
Byte 0:
 | 
						|
This byte holds the reading from the sensor. Sensors in Bank1 can be both
 | 
						|
volt and temp sensors, this is motherboard specific. The uGuru however does
 | 
						|
seem to know (be programmed with) what kindoff sensor is attached see Sensor
 | 
						|
Bank1 Settings description.
 | 
						|
 | 
						|
Volt sensors use a linear scale, a reading 0 corresponds with 0 volt and a
 | 
						|
reading of 255 with 3494 mV. The sensors for higher voltages however are
 | 
						|
connected through a division circuit. The currently known division circuits
 | 
						|
in use result in ranges of: 0-4361mV, 0-6248mV or 0-14510mV. 3.3 volt sources
 | 
						|
use the 0-4361mV range, 5 volt the 0-6248mV and 12 volt the 0-14510mV .
 | 
						|
 | 
						|
Temp sensors also use a linear scale, a reading of 0 corresponds with 0 degree
 | 
						|
Celsius and a reading of 255 with a reading of 255 degrees Celsius.
 | 
						|
 | 
						|
 | 
						|
Bank 0x22 Sensor Bank1 Settings (R)
 | 
						|
Bank 0x23 Sensor Bank1 Settings (W)
 | 
						|
-----------------------------------
 | 
						|
 | 
						|
This bank contains 16 sensors, for each sensor it contains 3 bytes. Each
 | 
						|
set of 3 bytes contains the settings for the sensor with the same sensor
 | 
						|
address in Bank 0x21 .
 | 
						|
 | 
						|
Byte 0:
 | 
						|
Alarm behaviour for the selected sensor. A 1 enables the described behaviour.
 | 
						|
Bit 0: Give an alarm if measured temp is over the warning threshold	(RW) *
 | 
						|
Bit 1: Give an alarm if measured volt is over the max threshold		(RW) **
 | 
						|
Bit 2: Give an alarm if measured volt is under the min threshold	(RW) **
 | 
						|
Bit 3: Beep if alarm							(RW)
 | 
						|
Bit 4: 1 if alarm cause measured temp is over the warning threshold	(R)
 | 
						|
Bit 5: 1 if alarm cause measured volt is over the max threshold		(R)
 | 
						|
Bit 6: 1 if alarm cause measured volt is under the min threshold	(R)
 | 
						|
Bit 7: Volt sensor: Shutdown if alarm persist for more than 4 seconds	(RW)
 | 
						|
       Temp sensor: Shutdown if temp is over the shutdown threshold	(RW)
 | 
						|
 | 
						|
*  This bit is only honored/used by the uGuru if a temp sensor is connected
 | 
						|
** This bit is only honored/used by the uGuru if a volt sensor is connected
 | 
						|
Note with some trickery this can be used to find out what kinda sensor is
 | 
						|
detected see the Linux kernel driver for an example with many comments on
 | 
						|
how todo this.
 | 
						|
 | 
						|
Byte 1:
 | 
						|
Temp sensor: warning threshold  (scale as bank 0x21)
 | 
						|
Volt sensor: min threshold      (scale as bank 0x21)
 | 
						|
 | 
						|
Byte 2:
 | 
						|
Temp sensor: shutdown threshold (scale as bank 0x21)
 | 
						|
Volt sensor: max threshold      (scale as bank 0x21)
 | 
						|
 | 
						|
 | 
						|
Bank 0x24 PWM outputs for FAN's (R)
 | 
						|
Bank 0x25 PWM outputs for FAN's (W)
 | 
						|
-----------------------------------
 | 
						|
 | 
						|
This bank contains 3 "sensors", for each sensor it contains 5 bytes.
 | 
						|
Sensor 0 usually controls the CPU fan
 | 
						|
Sensor 1 usually controls the NB (or chipset for single chip) fan
 | 
						|
Sensor 2 usually controls the System fan
 | 
						|
 | 
						|
Byte 0:
 | 
						|
Flag 0x80 to enable control, Fan runs at 100% when disabled.
 | 
						|
low nibble (temp)sensor address at bank 0x21 used for control.
 | 
						|
 | 
						|
Byte 1:
 | 
						|
0-255 = 0-12v (linear), specify voltage at which fan will rotate when under
 | 
						|
low threshold temp (specified in byte 3)
 | 
						|
 | 
						|
Byte 2:
 | 
						|
0-255 = 0-12v (linear), specify voltage at which fan will rotate when above
 | 
						|
high threshold temp (specified in byte 4)
 | 
						|
 | 
						|
Byte 3:
 | 
						|
Low threshold temp  (scale as bank 0x21)
 | 
						|
 | 
						|
byte 4:
 | 
						|
High threshold temp (scale as bank 0x21)
 | 
						|
 | 
						|
 | 
						|
Bank 0x26 Sensors Bank2 Values / Readings (R)
 | 
						|
---------------------------------------------
 | 
						|
 | 
						|
This bank contains 6 sensors (AFAIK), for each sensor it contains 1 byte.
 | 
						|
So far the following sensors are known to be available on all motherboards:
 | 
						|
Sensor 0: CPU fan speed
 | 
						|
Sensor 1: NB (or chipset for single chip) fan speed
 | 
						|
Sensor 2: SYS fan speed
 | 
						|
 | 
						|
Byte 0:
 | 
						|
This byte holds the reading from the sensor. 0-255 = 0-15300 (linear)
 | 
						|
 | 
						|
 | 
						|
Bank 0x27 Sensors Bank2 Settings (R)
 | 
						|
Bank 0x28 Sensors Bank2 Settings (W)
 | 
						|
------------------------------------
 | 
						|
 | 
						|
This bank contains 6 sensors (AFAIK), for each sensor it contains 2 bytes.
 | 
						|
 | 
						|
Byte 0:
 | 
						|
Alarm behaviour for the selected sensor. A 1 enables the described behaviour.
 | 
						|
Bit 0: Give an alarm if measured rpm is under the min threshold	(RW)
 | 
						|
Bit 3: Beep if alarm						(RW)
 | 
						|
Bit 7: Shutdown if alarm persist for more than 4 seconds	(RW)
 | 
						|
 | 
						|
Byte 1:
 | 
						|
min threshold (scale as bank 0x26)
 | 
						|
 | 
						|
 | 
						|
Warning for the adventurous
 | 
						|
===========================
 | 
						|
 | 
						|
A word of caution to those who want to experiment and see if they can figure
 | 
						|
the voltage / clock programming out, I tried reading and only reading banks
 | 
						|
0-0x30 with the reading code used for the sensor banks (0x20-0x28) and this
 | 
						|
resulted in a _permanent_ reprogramming of the voltages, luckily I had the
 | 
						|
sensors part configured so that it would shutdown my system on any out of spec
 | 
						|
voltages which proprably safed my computer (after a reboot I managed to
 | 
						|
immediately enter the bios and reload the defaults). This probably means that
 | 
						|
the read/write cycle for the non sensor part is different from the sensor part.
 |