| Kernel driver max6639
 | |
| =====================
 | |
| 
 | |
| Supported chips:
 | |
|   * Maxim MAX6639
 | |
|     Prefix: 'max6639'
 | |
|     Addresses scanned: I2C 0x2c, 0x2e, 0x2f
 | |
|     Datasheet: http://pdfserv.maxim-ic.com/en/ds/MAX6639.pdf
 | |
| 
 | |
| Authors:
 | |
|     He Changqing <hechangqing@semptian.com>
 | |
|     Roland Stigge <stigge@antcom.de>
 | |
| 
 | |
| Description
 | |
| -----------
 | |
| 
 | |
| This driver implements support for the Maxim MAX6639. This chip is a 2-channel
 | |
| temperature monitor with dual PWM fan speed controller. It can monitor its own
 | |
| temperature and one external diode-connected transistor or two external
 | |
| diode-connected transistors.
 | |
| 
 | |
| The following device attributes are implemented via sysfs:
 | |
| 
 | |
| Attribute              R/W  Contents
 | |
| ----------------------------------------------------------------------------
 | |
| temp1_input            R    Temperature channel 1 input (0..150 C)
 | |
| temp2_input            R    Temperature channel 2 input (0..150 C)
 | |
| temp1_fault            R    Temperature channel 1 diode fault
 | |
| temp2_fault            R    Temperature channel 2 diode fault
 | |
| temp1_max              RW   Set THERM temperature for input 1
 | |
|                             (in C, see datasheet)
 | |
| temp2_max              RW   Set THERM temperature for input 2
 | |
| temp1_crit             RW   Set ALERT temperature for input 1
 | |
| temp2_crit             RW   Set ALERT temperature for input 2
 | |
| temp1_emergency        RW   Set OT temperature for input 1
 | |
|                             (in C, see datasheet)
 | |
| temp2_emergency        RW   Set OT temperature for input 2
 | |
| pwm1                   RW   Fan 1 target duty cycle (0..255)
 | |
| pwm2                   RW   Fan 2 target duty cycle (0..255)
 | |
| fan1_input             R    TACH1 fan tachometer input (in RPM)
 | |
| fan2_input             R    TACH2 fan tachometer input (in RPM)
 | |
| fan1_fault             R    Fan 1 fault
 | |
| fan2_fault             R    Fan 2 fault
 | |
| temp1_max_alarm        R    Alarm on THERM temperature on channel 1
 | |
| temp2_max_alarm        R    Alarm on THERM temperature on channel 2
 | |
| temp1_crit_alarm       R    Alarm on ALERT temperature on channel 1
 | |
| temp2_crit_alarm       R    Alarm on ALERT temperature on channel 2
 | |
| temp1_emergency_alarm  R    Alarm on OT temperature on channel 1
 | |
| temp2_emergency_alarm  R    Alarm on OT temperature on channel 2
 |