61 lines
		
	
	
		
			2.0 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
			
		
		
	
	
			61 lines
		
	
	
		
			2.0 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
| Kernel driver max31785
 | |
| ======================
 | |
| 
 | |
| Supported chips:
 | |
|   * Maxim MAX31785, MAX31785A
 | |
|     Prefix: 'max31785' or 'max31785a'
 | |
|     Addresses scanned: -
 | |
|     Datasheet: https://datasheets.maximintegrated.com/en/ds/MAX31785.pdf
 | |
| 
 | |
| Author: Andrew Jeffery <andrew@aj.id.au>
 | |
| 
 | |
| Description
 | |
| -----------
 | |
| 
 | |
| The Maxim MAX31785 is a PMBus device providing closed-loop, multi-channel fan
 | |
| management with temperature and remote voltage sensing. Various fan control
 | |
| features are provided, including PWM frequency control, temperature hysteresis,
 | |
| dual tachometer measurements, and fan health monitoring.
 | |
| 
 | |
| For dual-rotor configurations the MAX31785A exposes the second rotor tachometer
 | |
| readings in attributes fan[5-8]_input. By contrast the MAX31785 only exposes
 | |
| the slowest rotor measurement, and does so in the fan[1-4]_input attributes.
 | |
| 
 | |
| Usage Notes
 | |
| -----------
 | |
| 
 | |
| This driver does not probe for PMBus devices. You will have to instantiate
 | |
| devices explicitly.
 | |
| 
 | |
| Sysfs attributes
 | |
| ----------------
 | |
| 
 | |
| fan[1-4]_alarm		Fan alarm.
 | |
| fan[1-4]_fault		Fan fault.
 | |
| fan[1-8]_input		Fan RPM. On the MAX31785A, inputs 5-8 correspond to the
 | |
| 			second rotor of fans 1-4
 | |
| fan[1-4]_target		Fan input target
 | |
| 
 | |
| in[1-6]_crit		Critical maximum output voltage
 | |
| in[1-6]_crit_alarm	Output voltage critical high alarm
 | |
| in[1-6]_input		Measured output voltage
 | |
| in[1-6]_label		"vout[18-23]"
 | |
| in[1-6]_lcrit		Critical minimum output voltage
 | |
| in[1-6]_lcrit_alarm	Output voltage critical low alarm
 | |
| in[1-6]_max		Maximum output voltage
 | |
| in[1-6]_max_alarm	Output voltage high alarm
 | |
| in[1-6]_min		Minimum output voltage
 | |
| in[1-6]_min_alarm	Output voltage low alarm
 | |
| 
 | |
| pwm[1-4]		Fan target duty cycle (0..255)
 | |
| pwm[1-4]_enable		0: Full-speed
 | |
| 			1: Manual PWM control
 | |
| 			2: Automatic PWM (tach-feedback RPM fan-control)
 | |
| 			3: Automatic closed-loop (temp-feedback fan-control)
 | |
| 
 | |
| temp[1-11]_crit		Critical high temperature
 | |
| temp[1-11]_crit_alarm	Chip temperature critical high alarm
 | |
| temp[1-11]_input	Measured temperature
 | |
| temp[1-11]_max		Maximum temperature
 | |
| temp[1-11]_max_alarm	Chip temperature high alarm
 |